QuickSpecs

HP AlphaServer GS1280 Systems

ES/GS Common Options

Infrastructure for

System Area Network Hub with four line cards; includes BN19P-1K` power cord

CCMHB-AA

Memory Channel

for Canada, Japan, and U.S. For other regions, order appropriate power cord

 

 

from list that follows.

 

 

Hub expansion box with no line cards

CCMHB-BA

 

Expansion line card for CCMHB hub

CCMLB-AA

 

1-meter cable for CCMAB and CCMHB

BN39B-01

 

4-meter cable for CCMAB and CCMHB

BN39B-04

 

7-meter cable for CCMAB and CCMHB

BN39B-07

 

10-meter cable for CCMAB and CCMHB

BN39B-10

 

Rackmount kit (3U) for CCMHB (Memory Channel Hub II); required for mounting

3X-BA61R-MD

 

in H9A40/H9A45 Cabinets and Series 10000 Racks.

 

 

Power cord for rackmount CCMHB hub

BN35S-02

 

 

Country-specific Power Australia, New Zealand

3R-A6023-AA

Cords for Standalone

Central Europe

BN19C-2E

MEMORY CHANNEL

Denmark

BN19K-2E

Hubs

Egypt, India

BN19S-2E

 

 

Ireland, United Kingdom

BN19A-2E

 

Israel

3R-A6883-AA

 

Italy

BN19M-2E

 

Japan, 2.5-meter, Dentori approved

3X-BN46F-02

 

Switzerland

BN19E-2E

 

 

 

Step 3 - Storage Adapters/Controllers — Optional

Description

Device Type

Part Number

Maximum Quantity Tested & Supported

U=Tru64 UNIX

O=OpenVMS

L=Redhat V7.2 Linux

per system

per hard partition: per system

ES47

ES47

ES80

GS1280

Tower

 

 

 

Workstation

 

 

 

SCSI Adapters

Ultra3 (LVD) SCSI adapter, dual- channel. Requires 3X-BC56J-xx cable. Restrictions: HSZxx RAID controllers not supported; Tru64 UNIX requires a graphics adapter to run console utilities (RUN BIOS).

PCI, 3.3V,

64b, 66 MHz

3X-KZPEA-DB

5/U

5/O

1/L

Shared Bus

5/U

0/O

28:28/U

12:24/O

1:2/L

Shared

Bus

6:12/U

0/O

32:56/U

12:48/O

1:4/L

Shared

Bus

6:24/U

0/O

32:576/U

12:384/O

0/L

Shared

Bus 6:192/U 0/O

 

 

 

 

 

DA - 11921 Worldwide — Version 24 — July 23, 2007

Page 33

Image 33
Contents QuickSpecs HP AlphaServer GS1280 Models 8HP AlphaServer GS1280 Model QuickSpecs At a Glance Power Supplies Boot/DiagnosticProcessor Cache MemoryQuickSpecs Requirements System Requirements Recommended ServicesOptional Purchases Requirements for PartitionsConfiguration Guidelines Licensing Systems for Both OpenVMS and Tru64 UnixQB-63PAQ-AC System Management Hardware/Software Requirements Select Base System MandatoryRacks Configuration and Use of instant Capacity iCAP CPUs Supported ConfigurationsCPU Building Block Modules Mandatory Full Use CPU BuildingICAP CPU Building ICAP EnablementTerms and Definitions First USEMemory Application Examples Select Memory Options Mandatory Configuration GuidelinesCPU OptionSystem I/O Expansion Mandatory Configuration Guidelines Memory SpecificationUSB ScsiDVD CD-RW Power Distribution Power Distribution Units MandatoryType a UnitsDual AC Power Optional Type a PowerDistribution Units QuickSpecs Internal System Expansion Optional AlphaServer GS1280 Model 8 Internal System Expansion OptionsQuickSpecs QuickSpecs QuickSpecs ES/GS Common Options Contents Calculated Maximum Throughput Calculated Maximum Throughput Bit data pathAGP Overall System Capacities for I/O Adapters and ControllersPCI-X/PCI slots in Standard I/O Drawers Per systemMaximum High Performance I/O Drawers Four MHz PCI-X/PCI slots in High Performance DrawersPCI Adapters Installed Max Bus Speed4X AGP Standard I/O Drawer used in ES47, ES80, and GS1280 SystemsSignal Voltage Adapters Installed Max Bus Speed Port Bus # Slot #To EV7 3X-KZPEA-DB 3X-KZPCA-AA 3X-KZPDC-BE/DF 3X-KZPEC-BF/DG U320 LVD ScsiRail Spacing Vertical Rack CapacityHole Pattern Max Payload specdRackmount Kits Ethernet Network Interface Cards Description3X-DEGXA-TR 3X-DEGXA-SRAsynchronous Communications Network Interface Cards Memory Channel Adapter Memory Channel Optional Configuration GuidelinesCCMAB-BA CCMFB-BAMemory Channel Cables for Scsi and Backplane RAID Controllers Backplane RAID Scsi ControllersFibre Channel Controllers Cipca AdapterModel MSA30, Single StorageWorks Enclosures for Disks and Tapes OptionalBus Model MSA30, Dual Bus Model MSA30 Multi1000 HP StorageWorks Enterprise Virtual Array Disks OptionalModel EVA4000 EVA6000 EVA8000 EVA8000HP StorageWorks Disk Array xp10000 DrivesSdlt External HP StorageWorks Sdlt Tape Drive FamilyHP StorageWorks DLT VS Tape Drive Family DLT VS ExternalUltrium LTO External HP StorageWorks Ultrium LTO Tape Drive FamilyAutoloader Ultrium LTO HP StorageWorks 1/8 Tape Autoloader FamilyAutoloader Rack Mount Kit HP StorageWorks MSL2024 Tape LibraryTransfer native Maximum DataHP StorageWorks MSL6000 Tape Libraries MSL6026 MSL6030 MSL6052 MSL6060 Form Factor# of drives possible # of slots Configuration EML 103e EML 245e EML 442e EML 505eProduct height within Rack Maximum CapacityVLS Raw Capacity SwitchesMaximum Raw Capacity Usable CapacityOpenVMS Note Monitors Configuration Guidelines Keyboard, Video, Mouse KVM SwitchesRackmount Keyboard/Drawer Keyboard/Monitor Options CAT5e CablesCarbon/Silver Monitors Monitor Power CordsCarbon/Silver Flat Panel MonitorsGraphics Software Graphics AdaptersQA-6ADAA-H8 QA-6ADAA-GZOpenVMS Rules OpenVMS Galaxy Galaxy Soft PartitionService Part Numbers Hardware and Software Support Services OptionalProgram Features Principal Server HP Support Plus System Codes forHP Proactive Critical ServicesInstallation Program Features Additional ServicesInstallation and Startup HP O/SBasic Integration ServiceYT-VISIT-B1 YT-VISIT-R1Partitioning Service Clustering ServiceConfigurations Full CustomGS1280 Conversion AlphaServer GS1280, Upgrades for Single SystemsKit GS1280 Conversion Kit3X-BNPSB-03 3X-BNPSB-04 3X-BA65C-AA 3X-BA65D-AAPower Distribution Unit 3X-H7606-AA North America Japan Europe Power RequirementsPower Distribution Unit 3X-H7606-BA PDU required for all GS1280 ModelsPower Distribution Unit Power Required, KvaGS1280 Models 3X-H7606 Power Distribution Unit Models 32 and 64 H7606-Bx Physical CharacteristicsService Clearances-All Operating Models Environmental Operating Non-OperatingAcoustics Declared values per ISO 9296 and ISO