HP GS1280 manual Usb, Scsi, Dvd Cd-Rw

Page 14

QuickSpecs

HP AlphaServer GS1280 Systems

GS Options

Total I/O Drawer Connections

=12 I/O connections used

 

I/O Module

 

for

 

Connection

 

to CPU in a

 

System

 

Building

 

Block

 

Drawer

Standard I/O

1

Drawer,

 

Expansion

 

 

 

Standard I/O

1

Drawer, Master

 

 

 

High

1 standard

Performance

3 additional,

I/O Drawer,

optional 1

Expansion

 

High

1 standard

Performance

3 additional,

I/O Drawer,

optional 1

Master

 

I/O Buses

3PCI-X

1AGP 4X

3PCI-X

1AGP 4X

2 to 8 PCI-X

2 to 8 PCI-X

I/O Slots

Dual

 

Redundant

 

Power

 

Supplies

 

 

8 PCI-X

Yes

1 PCI 3.3V;

 

2 PCI, 5V

 

1 AGP 4X

 

8 PCI-X

Yes

1 PCI 3.3V;

 

2 PCI, 5V

 

1 AGP 4X

 

2 to 8

Yes

PCI-X

 

 

 

2 to 8

Yes

PCI-X

 

 

 

USB/

Ultra3

SCSI

Adapter

Card

No

1 in PCI

3.3V Slot

No

1 in PCI-X

Slot

DVD/

CD-RW

Drive

No

1

No

1

Universal Part Number

Slot for

Disks

None

3X-BA70A-BA

 

 

24

3X-BA70A-AA

 

 

None

3X-BA70B-BA

 

 

24

3X-BA70B-AA

 

 

Add-in I/O Module for High Performance I/O Drawers. Each module supports two PCI-X slots. Up to three

3X-KFMHA-AA

modules may be added to the base High Performance I/O Drawer.

 

I/O 3.3-meter cable for connection between GS1280 System Building Block Drawer and I/O Building Block

3X-BNPSA-04

Drawers mounted in a system rack or adjacent expansion rack; select one cable for each I/O drawer

 

ordered and one cable per Add-in I/O Module (3X-KFMHA-AA) if ordered.

 

I/O 4.5-meter cable for connection spanning one or two racks between GS1280 System Building Block

3X-BNPSA-05

Drawer and I/O Building Block Drawer mounted in an expansion rack; select one cable for each I/O drawer

 

ordered and one cable per Add-in I/O Module (3X-KFMHA-AA) if ordered.

 

I/O 6.0-meter cable for connection spanning three racks between GS1280 System Building Block Drawer

3X-BNPSA-06

and I/O Building Block Drawer mounted in an expansion rack; select one cable for each I/O drawer

 

ordered and one cable per Add-in I/O Module (3X-KFMHA-AA) if ordered.

 

DA - 11921 Worldwide — Version 24 — July 23, 2007

Page 14

Image 14
Contents HP AlphaServer GS1280 Models 8 QuickSpecsHP AlphaServer GS1280 Model QuickSpecs At a Glance Processor Boot/DiagnosticPower Supplies Cache MemoryQuickSpecs Optional Purchases Recommended ServicesRequirements System Requirements Requirements for PartitionsQB-63PAQ-AC Configuration GuidelinesLicensing Systems for Both OpenVMS and Tru64 Unix Racks System Management Hardware/Software RequirementsSelect Base System Mandatory CPU Building Block Modules Mandatory Supported ConfigurationsConfiguration and Use of instant Capacity iCAP CPUs Full Use CPU BuildingTerms and Definitions ICAP EnablementICAP CPU Building First USECPU Select Memory Options Mandatory Configuration GuidelinesMemory Application Examples OptionMemory Specification System I/O Expansion Mandatory Configuration GuidelinesDVD CD-RW USBScsi Type a Power Distribution Units MandatoryPower Distribution UnitsDistribution Units Dual AC Power OptionalType a Power QuickSpecs AlphaServer GS1280 Model 8 Internal System Expansion Options Internal System Expansion OptionalQuickSpecs QuickSpecs QuickSpecs ES/GS Common Options Contents AGP Calculated Maximum Throughput Bit data pathCalculated Maximum Throughput Overall System Capacities for I/O Adapters and ControllersMaximum High Performance I/O Drawers Four Per systemPCI-X/PCI slots in Standard I/O Drawers MHz PCI-X/PCI slots in High Performance Drawers4X AGP Adapters Installed Max Bus SpeedPCI Standard I/O Drawer used in ES47, ES80, and GS1280 SystemsTo EV7 Signal Voltage Adapters Installed Max Bus SpeedPort Bus # Slot # U320 LVD Scsi 3X-KZPEA-DB 3X-KZPCA-AA 3X-KZPDC-BE/DF 3X-KZPEC-BF/DGHole Pattern Vertical Rack CapacityRail Spacing Max Payload specdRackmount Kits 3X-DEGXA-TR DescriptionEthernet Network Interface Cards 3X-DEGXA-SRAsynchronous Communications Network Interface Cards CCMAB-BA Memory Channel Optional Configuration GuidelinesMemory Channel Adapter CCMFB-BAMemory Channel Fibre Channel Controllers Backplane RAID Scsi ControllersCables for Scsi and Backplane RAID Controllers Cipca AdapterBus Model MSA30, Dual StorageWorks Enclosures for Disks and Tapes OptionalModel MSA30, Single Bus Model MSA30 MultiDisks Optional 1000 HP StorageWorks Enterprise Virtual ArrayHP StorageWorks Disk Array xp10000 EVA8000Model EVA4000 EVA6000 EVA8000 DrivesHP StorageWorks DLT VS Tape Drive Family HP StorageWorks Sdlt Tape Drive FamilySdlt External DLT VS ExternalHP StorageWorks Ultrium LTO Tape Drive Family Ultrium LTO ExternalAutoloader Rack Mount Kit HP StorageWorks 1/8 Tape Autoloader FamilyAutoloader Ultrium LTO HP StorageWorks MSL2024 Tape LibraryHP StorageWorks MSL6000 Tape Libraries Maximum DataTransfer native MSL6026 MSL6030 MSL6052 MSL6060 Form FactorProduct height within Configuration EML 103e EML 245e EML 442e EML 505e# of drives possible # of slots Rack Maximum CapacityMaximum Raw SwitchesVLS Raw Capacity Capacity Usable CapacityOpenVMS Note Rackmount Keyboard/Drawer Keyboard/Monitor Options Keyboard, Video, Mouse KVM SwitchesMonitors Configuration Guidelines CAT5e CablesCarbon/Silver Flat Monitor Power CordsCarbon/Silver Monitors Panel MonitorsGraphics Adapters Graphics SoftwareOpenVMS QA-6ADAA-H8QA-6ADAA-GZ OpenVMS Galaxy Galaxy Soft Partition RulesProgram Features Principal Server HP Support Plus Hardware and Software Support Services OptionalService Part Numbers System Codes forCritical Services HP ProactiveInstallation and Startup Program Features Additional ServicesInstallation HP O/SYT-VISIT-B1 ServiceBasic Integration YT-VISIT-R1Configurations Clustering ServicePartitioning Service Full CustomKit AlphaServer GS1280, Upgrades for Single SystemsGS1280 Conversion GS1280 Conversion Kit3X-BA65C-AA 3X-BA65D-AA 3X-BNPSB-03 3X-BNPSB-04Power Distribution Unit 3X-H7606-BA North America Japan Europe Power RequirementsPower Distribution Unit 3X-H7606-AA PDU required for all GS1280 ModelsGS1280 Models 3X-H7606 Power Distribution Unit Power Required, KvaPower Distribution Unit Models 32 and 64 H7606-Bx Physical CharacteristicsAcoustics Declared values per ISO 9296 and ISO Service Clearances-All Operating ModelsEnvironmental Operating Non-Operating