HP GS1280 manual QuickSpecs

Page 6

QuickSpecs

HP AlphaServer GS1280 Systems

Standard Features

Service and Support Protected by HP Services including a 1-year on-site hardware warranty. Training, consulting, network integration, software support, comprehensive system maintenance and guaranteed uptime services are also available for customers requiring higher levels of service and support.

DA - 11921 Worldwide — Version 24 — July 23, 2007

Page 6

Image 6
Contents HP AlphaServer GS1280 Models 8 QuickSpecsHP AlphaServer GS1280 Model QuickSpecs At a Glance Processor Boot/DiagnosticPower Supplies Cache MemoryQuickSpecs Optional Purchases Recommended ServicesRequirements System Requirements Requirements for PartitionsConfiguration Guidelines Licensing Systems for Both OpenVMS and Tru64 UnixQB-63PAQ-AC System Management Hardware/Software Requirements Select Base System MandatoryRacks CPU Building Block Modules Mandatory Supported ConfigurationsConfiguration and Use of instant Capacity iCAP CPUs Full Use CPU BuildingTerms and Definitions ICAP EnablementICAP CPU Building First USECPU Select Memory Options Mandatory Configuration GuidelinesMemory Application Examples OptionMemory Specification System I/O Expansion Mandatory Configuration GuidelinesUSB ScsiDVD CD-RW Type a Power Distribution Units MandatoryPower Distribution UnitsDual AC Power Optional Type a PowerDistribution Units QuickSpecs AlphaServer GS1280 Model 8 Internal System Expansion Options Internal System Expansion OptionalQuickSpecs QuickSpecs QuickSpecs ES/GS Common Options Contents AGP Calculated Maximum Throughput Bit data pathCalculated Maximum Throughput Overall System Capacities for I/O Adapters and ControllersMaximum High Performance I/O Drawers Four Per systemPCI-X/PCI slots in Standard I/O Drawers MHz PCI-X/PCI slots in High Performance Drawers4X AGP Adapters Installed Max Bus SpeedPCI Standard I/O Drawer used in ES47, ES80, and GS1280 SystemsSignal Voltage Adapters Installed Max Bus Speed Port Bus # Slot #To EV7 U320 LVD Scsi 3X-KZPEA-DB 3X-KZPCA-AA 3X-KZPDC-BE/DF 3X-KZPEC-BF/DGHole Pattern Vertical Rack CapacityRail Spacing Max Payload specdRackmount Kits 3X-DEGXA-TR DescriptionEthernet Network Interface Cards 3X-DEGXA-SRAsynchronous Communications Network Interface Cards CCMAB-BA Memory Channel Optional Configuration GuidelinesMemory Channel Adapter CCMFB-BAMemory Channel Fibre Channel Controllers Backplane RAID Scsi ControllersCables for Scsi and Backplane RAID Controllers Cipca AdapterBus Model MSA30, Dual StorageWorks Enclosures for Disks and Tapes OptionalModel MSA30, Single Bus Model MSA30 MultiDisks Optional 1000 HP StorageWorks Enterprise Virtual ArrayHP StorageWorks Disk Array xp10000 EVA8000Model EVA4000 EVA6000 EVA8000 DrivesHP StorageWorks DLT VS Tape Drive Family HP StorageWorks Sdlt Tape Drive FamilySdlt External DLT VS ExternalHP StorageWorks Ultrium LTO Tape Drive Family Ultrium LTO ExternalAutoloader Rack Mount Kit HP StorageWorks 1/8 Tape Autoloader FamilyAutoloader Ultrium LTO HP StorageWorks MSL2024 Tape LibraryHP StorageWorks MSL6000 Tape Libraries Maximum DataTransfer native MSL6026 MSL6030 MSL6052 MSL6060 Form FactorProduct height within Configuration EML 103e EML 245e EML 442e EML 505e# of drives possible # of slots Rack Maximum CapacityMaximum Raw SwitchesVLS Raw Capacity Capacity Usable CapacityOpenVMS Note Rackmount Keyboard/Drawer Keyboard/Monitor Options Keyboard, Video, Mouse KVM SwitchesMonitors Configuration Guidelines CAT5e CablesCarbon/Silver Flat Monitor Power CordsCarbon/Silver Monitors Panel MonitorsGraphics Adapters Graphics SoftwareQA-6ADAA-H8 QA-6ADAA-GZOpenVMS OpenVMS Galaxy Galaxy Soft Partition RulesProgram Features Principal Server HP Support Plus Hardware and Software Support Services OptionalService Part Numbers System Codes forCritical Services HP ProactiveInstallation and Startup Program Features Additional ServicesInstallation HP O/SYT-VISIT-B1 ServiceBasic Integration YT-VISIT-R1Configurations Clustering ServicePartitioning Service Full CustomKit AlphaServer GS1280, Upgrades for Single SystemsGS1280 Conversion GS1280 Conversion Kit3X-BA65C-AA 3X-BA65D-AA 3X-BNPSB-03 3X-BNPSB-04Power Distribution Unit 3X-H7606-BA North America Japan Europe Power RequirementsPower Distribution Unit 3X-H7606-AA PDU required for all GS1280 ModelsGS1280 Models 3X-H7606 Power Distribution Unit Power Required, KvaPower Distribution Unit Models 32 and 64 H7606-Bx Physical CharacteristicsService Clearances-All Operating Models Environmental Operating Non-OperatingAcoustics Declared values per ISO 9296 and ISO