HP GS1280 manual At a Glance

Page 4

QuickSpecs

HP AlphaServer GS1280 Systems

Overview

At A Glance

AlphaServer GS1280 Systems

Up to 64 Alpha 21364 EV7 processors at 1300 MHz and 1150 MHz with advanced on-chip memory controllers and switch logic capable of providing 12.3 GB/s of memory bandwidth per processor

Choice of memory options; up to 8 GB of RDRAM memory per CPU supported (512 GB total for a 64P system) Redundant features providing maximum uptime - N+1 Voltage Regulator Modules (VRMs); hot- plug redundant power supplies; cooling provided by hot-plug redundant system fans; dual AC input is standard

Optional RAID memory support

Standard I/O Drawer with 11 configurable PCI-X/PCI slots and one AGP slot; hot-swap power supplies High-performance I/O Drawer with eight PCI-X slots @133 MHz; hot-swap power supplies Enhanced reliability with ECC-protected memory, processor cache, and system data paths

Tru64 UNIX or OpenVMS factory installed software (FIS); optional high availability support with Tru64 UNIX and OpenVMS cluster solutions

Product warranty, 1-year hardware, on-site next business day and 90-day software, telephone support delivered by HP Services

Base Systems Contents

Step 1

Requirements

Step 1a

System Requirements

Step 1b

Requirements for Partitions

Step 1c

Licensing Systems for Both OpenVMS and Tru64 UNIX

Step 1d

System Management Hardware/Software Requirements

Step 2

Select Base System - Mandatory

Step 3

CPU Building Blocks - Mandatory

Step 4

Select Memory Options - Mandatory

Step 5

System I/O Expansion - Mandatory

Step 6

Power Distribution Units - Mandatory

Step 7

Dual AC Power - Optional

Step 8

Internal System Expansion - Optional

Step 9

External Rack Expansion - Optional

ES/GS Common Options - Hardware Options & Peripherals, Software, and Services

Upgrades

Technical Specifications

DA - 11921 Worldwide — Version 24 — July 23, 2007

Page 4

Image 4
Contents HP AlphaServer GS1280 Models 8 QuickSpecsHP AlphaServer GS1280 Model QuickSpecs At a Glance Boot/Diagnostic Power SuppliesProcessor Cache MemoryQuickSpecs Recommended Services Requirements System RequirementsOptional Purchases Requirements for PartitionsLicensing Systems for Both OpenVMS and Tru64 Unix Configuration GuidelinesQB-63PAQ-AC Select Base System Mandatory System Management Hardware/Software RequirementsRacks Supported Configurations Configuration and Use of instant Capacity iCAP CPUsCPU Building Block Modules Mandatory Full Use CPU BuildingICAP Enablement ICAP CPU BuildingTerms and Definitions First USESelect Memory Options Mandatory Configuration Guidelines Memory Application ExamplesCPU OptionMemory Specification System I/O Expansion Mandatory Configuration GuidelinesScsi USBDVD CD-RW Power Distribution Units Mandatory Power DistributionType a UnitsType a Power Dual AC Power OptionalDistribution Units QuickSpecs AlphaServer GS1280 Model 8 Internal System Expansion Options Internal System Expansion OptionalQuickSpecs QuickSpecs QuickSpecs ES/GS Common Options Contents Calculated Maximum Throughput Bit data path Calculated Maximum ThroughputAGP Overall System Capacities for I/O Adapters and ControllersPer system PCI-X/PCI slots in Standard I/O DrawersMaximum High Performance I/O Drawers Four MHz PCI-X/PCI slots in High Performance DrawersAdapters Installed Max Bus Speed PCI4X AGP Standard I/O Drawer used in ES47, ES80, and GS1280 SystemsPort Bus # Slot # Signal Voltage Adapters Installed Max Bus SpeedTo EV7 U320 LVD Scsi 3X-KZPEA-DB 3X-KZPCA-AA 3X-KZPDC-BE/DF 3X-KZPEC-BF/DGVertical Rack Capacity Rail SpacingHole Pattern Max Payload specdRackmount Kits Description Ethernet Network Interface Cards3X-DEGXA-TR 3X-DEGXA-SRAsynchronous Communications Network Interface Cards Memory Channel Optional Configuration Guidelines Memory Channel AdapterCCMAB-BA CCMFB-BAMemory Channel Backplane RAID Scsi Controllers Cables for Scsi and Backplane RAID ControllersFibre Channel Controllers Cipca AdapterStorageWorks Enclosures for Disks and Tapes Optional Model MSA30, SingleBus Model MSA30, Dual Bus Model MSA30 MultiDisks Optional 1000 HP StorageWorks Enterprise Virtual ArrayEVA8000 Model EVA4000 EVA6000 EVA8000HP StorageWorks Disk Array xp10000 DrivesHP StorageWorks Sdlt Tape Drive Family Sdlt ExternalHP StorageWorks DLT VS Tape Drive Family DLT VS ExternalHP StorageWorks Ultrium LTO Tape Drive Family Ultrium LTO ExternalHP StorageWorks 1/8 Tape Autoloader Family Autoloader Ultrium LTOAutoloader Rack Mount Kit HP StorageWorks MSL2024 Tape LibraryMaximum Data Transfer nativeHP StorageWorks MSL6000 Tape Libraries MSL6026 MSL6030 MSL6052 MSL6060 Form FactorConfiguration EML 103e EML 245e EML 442e EML 505e # of drives possible # of slotsProduct height within Rack Maximum CapacitySwitches VLS Raw CapacityMaximum Raw Capacity Usable CapacityOpenVMS Note Keyboard, Video, Mouse KVM Switches Monitors Configuration GuidelinesRackmount Keyboard/Drawer Keyboard/Monitor Options CAT5e CablesMonitor Power Cords Carbon/Silver MonitorsCarbon/Silver Flat Panel MonitorsGraphics Adapters Graphics SoftwareQA-6ADAA-GZ QA-6ADAA-H8OpenVMS OpenVMS Galaxy Galaxy Soft Partition RulesHardware and Software Support Services Optional Service Part NumbersProgram Features Principal Server HP Support Plus System Codes forCritical Services HP ProactiveProgram Features Additional Services InstallationInstallation and Startup HP O/SService Basic IntegrationYT-VISIT-B1 YT-VISIT-R1Clustering Service Partitioning ServiceConfigurations Full CustomAlphaServer GS1280, Upgrades for Single Systems GS1280 ConversionKit GS1280 Conversion Kit3X-BA65C-AA 3X-BA65D-AA 3X-BNPSB-03 3X-BNPSB-04North America Japan Europe Power Requirements Power Distribution Unit 3X-H7606-AAPower Distribution Unit 3X-H7606-BA PDU required for all GS1280 ModelsPower Required, Kva Power Distribution UnitGS1280 Models 3X-H7606 Power Distribution Unit Models 32 and 64 H7606-Bx Physical CharacteristicsEnvironmental Operating Non-Operating Service Clearances-All Operating ModelsAcoustics Declared values per ISO 9296 and ISO