HP GS1280 manual Power Distribution Units Mandatory, Type a, Type B

Page 15

QuickSpecs

HP AlphaServer GS1280 Systems

GS Options

NOTES:

1.One High Performance I/O Drawer can be used by up to four separate hard partitions. Each of the four I/O connections (and two associated PCI-X slots) in the High Performance I/O Drawer can be independently controlled (e.g. power on/off) in conjunction with a separate partition.

2.A Master I/O Drawer consists of a Standard or High Performance I/O Drawer plus a Combination Adapter in one slot. The Combination Adapter provides an Ultra3 SCSI connection for two disks and a DVD/CD-RW drive in the drawer, plus a USB connection for keyboard, mouse, and monitor. The Master I/O Drawer is required for all GS1280 systems integrated at the manufacturing plant by HP. If the final system configuration does not require these I/O devices, the Combination Adapter may be removed and replaced with the following alternatives:

System Boot - External storage or network boot can be used in place of the disk storage internal to the I/O Drawer.

Software Load - Software can be loaded over the network from a disk on another system or directly from a CD reader attached to another system by using remote mount.

User I/O - User access via a network connection can be used in place of the direct connection via the USB port.

3.The two disks in the Master I/O Drawer can only be connected to the system via the Combination Adapter's Ultra3 SCSI connection. The I/O Drawer design does not permit connection from other storage adapters, such as a RAID adapter, that might be installed in the I/O Drawer.

4.Each Master I/O Drawer supports up to two, optional, hard disk drives. See the Disks step of the ES/GS Common Options section of this QuickSpec for the selection of supported disk drives.

Step 6 - Power Distribution Units - Mandatory

 

 

 

GS1280 Model

GS1280 Model

GS1280 Model

GS1280 Model

 

 

 

8

16

32

64

 

 

 

DA/DY-1280A-

DA/DY-1280A-

DA/DY-1280A-

DA/DY-1280A-

 

 

 

AA

BA

CC

BD

Type A

North America/Japan 200

 

 

 

2 required

2 required

Power Distribution

-208V, NEMA L21-30P

3X-H7606-

1 required

2 required

(provides

(provides

Units

30A; 3 x C19 outlets plus

AA

receptacles for

receptacles for

(provides

(provides

Select one variant.

24 x C13 outlets

 

power cords

power cords

 

receptacles for

receptacles for

 

 

 

from I/O

from I/O

 

International 380/415V Y,

 

power cords

power cords

 

 

Drawers, LAN

Drawers, LAN

 

IEC 309 32A; 3 x C19

3X-H7606-

from all system

from all system

 

Hub, and

Hub, and

 

outlets plus 24 x C13

AB

components)

components)

storage

storage

 

 

 

 

outlets

 

 

 

shelves)

shelves)

Type B

North America/Japan

3X-H7606-

Not applicable

Not applicable

2 required

4 required

Power Distribution

200 - 208V, IEC 309 60A

BA

 

 

(for M32/M64

(for M32/M64

Units

 

 

 

 

Dual AC power

Dual AC power

Select one variant.

International

3X-H7606-

 

 

supply

supply

 

380/415V Y, IEC 309

BB

 

 

exclusively for

exclusively for

 

32A

 

 

 

8P system

8P system

 

 

 

 

 

drawers)

drawers)

NOTES:

1.Select the same power supply voltage variant for both Type A and Type B Power Distribution Units, e.g. both 200- 208V or both 380/415V.

2.IEC 309 is a general spec that can encompass 3 different pin types. The 3X-H7606-BA PDU uses the Hubbell 460P9W, a 4 pin connector.

3.The 3X-H7606-AA PDU uses an L21-30P 30 amp plug, Hubbell 2811, a 4 pin connector.

DA - 11921 Worldwide — Version 24 — July 23, 2007

Page 15

Image 15
Contents QuickSpecs HP AlphaServer GS1280 Models 8HP AlphaServer GS1280 Model QuickSpecs At a Glance Cache Memory Boot/DiagnosticPower Supplies ProcessorQuickSpecs Requirements for Partitions Recommended ServicesRequirements System Requirements Optional PurchasesConfiguration Guidelines Licensing Systems for Both OpenVMS and Tru64 UnixQB-63PAQ-AC System Management Hardware/Software Requirements Select Base System MandatoryRacks Full Use CPU Building Supported ConfigurationsConfiguration and Use of instant Capacity iCAP CPUs CPU Building Block Modules MandatoryFirst USE ICAP EnablementICAP CPU Building Terms and DefinitionsOption Select Memory Options Mandatory Configuration GuidelinesMemory Application Examples CPUSystem I/O Expansion Mandatory Configuration Guidelines Memory SpecificationUSB ScsiDVD CD-RW Units Power Distribution Units MandatoryPower Distribution Type aDual AC Power Optional Type a PowerDistribution Units QuickSpecs Internal System Expansion Optional AlphaServer GS1280 Model 8 Internal System Expansion OptionsQuickSpecs QuickSpecs QuickSpecs ES/GS Common Options Contents Overall System Capacities for I/O Adapters and Controllers Calculated Maximum Throughput Bit data pathCalculated Maximum Throughput AGPMHz PCI-X/PCI slots in High Performance Drawers Per systemPCI-X/PCI slots in Standard I/O Drawers Maximum High Performance I/O Drawers FourStandard I/O Drawer used in ES47, ES80, and GS1280 Systems Adapters Installed Max Bus SpeedPCI 4X AGPSignal Voltage Adapters Installed Max Bus Speed Port Bus # Slot #To EV7 3X-KZPEA-DB 3X-KZPCA-AA 3X-KZPDC-BE/DF 3X-KZPEC-BF/DG U320 LVD ScsiMax Payload specd Vertical Rack CapacityRail Spacing Hole PatternRackmount Kits 3X-DEGXA-SR DescriptionEthernet Network Interface Cards 3X-DEGXA-TRAsynchronous Communications Network Interface Cards CCMFB-BA Memory Channel Optional Configuration GuidelinesMemory Channel Adapter CCMAB-BAMemory Channel Cipca Adapter Backplane RAID Scsi ControllersCables for Scsi and Backplane RAID Controllers Fibre Channel ControllersBus Model MSA30 Multi StorageWorks Enclosures for Disks and Tapes OptionalModel MSA30, Single Bus Model MSA30, Dual1000 HP StorageWorks Enterprise Virtual Array Disks OptionalDrives EVA8000Model EVA4000 EVA6000 EVA8000 HP StorageWorks Disk Array xp10000DLT VS External HP StorageWorks Sdlt Tape Drive FamilySdlt External HP StorageWorks DLT VS Tape Drive FamilyUltrium LTO External HP StorageWorks Ultrium LTO Tape Drive FamilyHP StorageWorks MSL2024 Tape Library HP StorageWorks 1/8 Tape Autoloader FamilyAutoloader Ultrium LTO Autoloader Rack Mount KitMSL6026 MSL6030 MSL6052 MSL6060 Form Factor Maximum DataTransfer native HP StorageWorks MSL6000 Tape LibrariesRack Maximum Capacity Configuration EML 103e EML 245e EML 442e EML 505e# of drives possible # of slots Product height withinCapacity Usable Capacity SwitchesVLS Raw Capacity Maximum RawOpenVMS Note CAT5e Cables Keyboard, Video, Mouse KVM SwitchesMonitors Configuration Guidelines Rackmount Keyboard/Drawer Keyboard/Monitor OptionsPanel Monitors Monitor Power CordsCarbon/Silver Monitors Carbon/Silver FlatGraphics Software Graphics AdaptersQA-6ADAA-H8 QA-6ADAA-GZOpenVMS Rules OpenVMS Galaxy Galaxy Soft PartitionSystem Codes for Hardware and Software Support Services OptionalService Part Numbers Program Features Principal Server HP Support PlusHP Proactive Critical ServicesHP O/S Program Features Additional ServicesInstallation Installation and StartupYT-VISIT-R1 ServiceBasic Integration YT-VISIT-B1Full Custom Clustering ServicePartitioning Service ConfigurationsGS1280 Conversion Kit AlphaServer GS1280, Upgrades for Single SystemsGS1280 Conversion Kit3X-BNPSB-03 3X-BNPSB-04 3X-BA65C-AA 3X-BA65D-AAPDU required for all GS1280 Models North America Japan Europe Power RequirementsPower Distribution Unit 3X-H7606-AA Power Distribution Unit 3X-H7606-BAModels 32 and 64 H7606-Bx Physical Characteristics Power Required, KvaPower Distribution Unit GS1280 Models 3X-H7606 Power Distribution UnitService Clearances-All Operating Models Environmental Operating Non-OperatingAcoustics Declared values per ISO 9296 and ISO