HP GS1280 Select Memory Options Mandatory Configuration Guidelines, Memory Application Examples

Page 12

QuickSpecs

HP AlphaServer GS1280 Systems

GS Options

Step 4 - Select Memory Options - Mandatory

Configuration Guidelines

1.Mandatory selection of one memory option per CPU (two memory options per Dual CPU Building Block Module).

2.Optional selection of a second memory option for each CPU.

3.Both options must be the same size and speed for a CPU, but different size options can be used on different CPUs.

4.Each memory option consists of four RDRAM Inline Memory Modules (RIMMs). An optional fifth RIMM (RAID option) may be selected for redundancy that will allow uninterrupted operation in case of the loss of an entire RIMM. RAID options must be selected and matched for each memory option on one CPU, but RAID options do not have to be selected for all CPUs.

NOTE: Memory must be ordered for iCAP CPU Modules as well as Full Use CPU Modules. The system will use memory installed on the iCAP CPU Module even when the iCAP CPU is inactive.

Memory Application Examples

The following examples illustrate different ways of configuring one 8P System Building Block Drawer with eight CPUs and a total of 16 GB of memory.

Case

A

B

 

 

CPU Building Block Module #1

 

CPU Building Block Module #2

 

Memory

 

CPU 1

CPU 2

 

CPU 3

 

CPU 4

 

Option

Controller 1

Controller 2

Controller 1

Controller 2

Controller 1

Controller 2

Controller 1

Controller 2

 

3X-MS7AB-

1

 

1

1

 

1

1

 

1

1

 

1

BA

 

 

 

 

 

 

 

 

 

 

 

 

(4 x 256

 

 

 

 

 

 

 

 

 

 

 

 

MB)

 

 

 

 

 

 

 

 

 

 

 

 

3X-MS7AB-

1

 

-

1

 

-

1

 

-

1

 

-

CA

 

 

 

 

 

 

 

 

 

 

 

 

(4 x 512

 

 

 

 

 

 

 

 

 

 

 

 

MB)

 

 

 

 

 

 

 

 

 

 

 

 

A

B

 

 

CPU Building Block Module #3

 

CPU Building Block Module #4

 

 

 

CPU 5

CPU 6

 

CPU 7

 

CPU 8

 

 

Controller 1

Controller 2

Controller 1

Controller 2

Controller 1

Controller 2

Controller 1

Controller 2

3X-MS7AB-

1

 

1

1

 

1

1

 

1

1

 

1

BA

 

 

 

 

 

 

 

 

 

 

 

 

(4 x 256

 

 

 

 

 

 

 

 

 

 

 

 

MB)

 

 

 

 

 

 

 

 

 

 

 

 

3X-MS7AB-

1

 

-

1

 

-

1

 

-

1

 

-

CA

 

 

 

 

 

 

 

 

 

 

 

 

(4 x 512

 

 

 

 

 

 

 

 

 

 

 

 

MB)

 

 

 

 

 

 

 

 

 

 

 

 

DA - 11921 Worldwide — Version 24 — July 23, 2007

Page 12

Image 12
Contents HP AlphaServer GS1280 Models 8 QuickSpecsHP AlphaServer GS1280 Model QuickSpecs At a Glance Boot/Diagnostic Power SuppliesProcessor Cache MemoryQuickSpecs Recommended Services Requirements System RequirementsOptional Purchases Requirements for PartitionsConfiguration Guidelines Licensing Systems for Both OpenVMS and Tru64 UnixQB-63PAQ-AC System Management Hardware/Software Requirements Select Base System MandatoryRacks Supported Configurations Configuration and Use of instant Capacity iCAP CPUsCPU Building Block Modules Mandatory Full Use CPU BuildingICAP Enablement ICAP CPU BuildingTerms and Definitions First USESelect Memory Options Mandatory Configuration Guidelines Memory Application ExamplesCPU OptionMemory Specification System I/O Expansion Mandatory Configuration GuidelinesUSB ScsiDVD CD-RW Power Distribution Units Mandatory Power DistributionType a UnitsDual AC Power Optional Type a PowerDistribution Units QuickSpecs AlphaServer GS1280 Model 8 Internal System Expansion Options Internal System Expansion OptionalQuickSpecs QuickSpecs QuickSpecs ES/GS Common Options Contents Calculated Maximum Throughput Bit data path Calculated Maximum ThroughputAGP Overall System Capacities for I/O Adapters and ControllersPer system PCI-X/PCI slots in Standard I/O DrawersMaximum High Performance I/O Drawers Four MHz PCI-X/PCI slots in High Performance DrawersAdapters Installed Max Bus Speed PCI4X AGP Standard I/O Drawer used in ES47, ES80, and GS1280 SystemsSignal Voltage Adapters Installed Max Bus Speed Port Bus # Slot #To EV7 U320 LVD Scsi 3X-KZPEA-DB 3X-KZPCA-AA 3X-KZPDC-BE/DF 3X-KZPEC-BF/DGVertical Rack Capacity Rail SpacingHole Pattern Max Payload specdRackmount Kits Description Ethernet Network Interface Cards3X-DEGXA-TR 3X-DEGXA-SRAsynchronous Communications Network Interface Cards Memory Channel Optional Configuration Guidelines Memory Channel AdapterCCMAB-BA CCMFB-BAMemory Channel Backplane RAID Scsi Controllers Cables for Scsi and Backplane RAID ControllersFibre Channel Controllers Cipca AdapterStorageWorks Enclosures for Disks and Tapes Optional Model MSA30, SingleBus Model MSA30, Dual Bus Model MSA30 MultiDisks Optional 1000 HP StorageWorks Enterprise Virtual ArrayEVA8000 Model EVA4000 EVA6000 EVA8000HP StorageWorks Disk Array xp10000 DrivesHP StorageWorks Sdlt Tape Drive Family Sdlt ExternalHP StorageWorks DLT VS Tape Drive Family DLT VS ExternalHP StorageWorks Ultrium LTO Tape Drive Family Ultrium LTO ExternalHP StorageWorks 1/8 Tape Autoloader Family Autoloader Ultrium LTOAutoloader Rack Mount Kit HP StorageWorks MSL2024 Tape LibraryMaximum Data Transfer nativeHP StorageWorks MSL6000 Tape Libraries MSL6026 MSL6030 MSL6052 MSL6060 Form FactorConfiguration EML 103e EML 245e EML 442e EML 505e # of drives possible # of slotsProduct height within Rack Maximum CapacitySwitches VLS Raw CapacityMaximum Raw Capacity Usable CapacityOpenVMS Note Keyboard, Video, Mouse KVM Switches Monitors Configuration GuidelinesRackmount Keyboard/Drawer Keyboard/Monitor Options CAT5e CablesMonitor Power Cords Carbon/Silver MonitorsCarbon/Silver Flat Panel MonitorsGraphics Adapters Graphics SoftwareQA-6ADAA-H8 QA-6ADAA-GZOpenVMS OpenVMS Galaxy Galaxy Soft Partition RulesHardware and Software Support Services Optional Service Part NumbersProgram Features Principal Server HP Support Plus System Codes forCritical Services HP ProactiveProgram Features Additional Services InstallationInstallation and Startup HP O/SService Basic IntegrationYT-VISIT-B1 YT-VISIT-R1Clustering Service Partitioning ServiceConfigurations Full CustomAlphaServer GS1280, Upgrades for Single Systems GS1280 ConversionKit GS1280 Conversion Kit3X-BA65C-AA 3X-BA65D-AA 3X-BNPSB-03 3X-BNPSB-04North America Japan Europe Power Requirements Power Distribution Unit 3X-H7606-AAPower Distribution Unit 3X-H7606-BA PDU required for all GS1280 ModelsPower Required, Kva Power Distribution UnitGS1280 Models 3X-H7606 Power Distribution Unit Models 32 and 64 H7606-Bx Physical CharacteristicsService Clearances-All Operating Models Environmental Operating Non-OperatingAcoustics Declared values per ISO 9296 and ISO