HP GS1280 manual U320 LVD Scsi, 3X-KZPEA-DB 3X-KZPCA-AA 3X-KZPDC-BE/DF 3X-KZPEC-BF/DG

Page 27

QuickSpecs

HP AlphaServer GS1280 Systems

ES/GS Common Options

Reference 2 – Adapter to Peripheral Cross Connect Table

 

 

 

 

Ultra3 SCSI

U320 LVD SCSI

 

SCSI Ultra3 LVD

SCSI Ultra2 LVD

Backplane RAID,

Backplane RAID,

 

 

 

 

2 or 4 channel

2 or 4 channel

 

3X-KZPEA-DB

 

3X-KZPCA-AA

3X-KZPDC-BE/DF

3X-KZPEC-BF/DG

MSA30 Rack Disk & Tape Drive

Yes

 

Yes

Yes

Yes

Enclosure

 

 

 

 

 

 

4300 Rack Disk & Tape Drive

Yes

 

Yes

Yes

Yes

Enclosure

 

 

 

 

 

 

1U Rackmount Tape Drive Enclosure

Yes

 

Yes

no

no

3U Rackmount Tape Drive Enclosure

Yes

 

Yes

no

no

MSA1000 Storage System

no

 

no

no

no

HP StorageWorks Enterprise Virtual

no

 

no

no

no

Arrays; EVA4000; EVA6000; EVA8000

 

 

 

 

 

 

HP StorageWorks Disk Arrays;

no

 

no

no

no

xp10000; xp12000

 

 

 

 

 

 

DAT Tape Drives; 40; 72

Yes

 

Yes

no

no

DLT VS Tape Drives; 80; 160

Yes

 

Yes

no

no

Ultrium LTO Tape Drives; 232; 448;

Yes

 

Yes

no

no

920, 460; 960

 

 

 

 

 

 

SDLT Tape Drive; 320; 600

Yes

 

Yes

no

no

DAT 72/10 Autoloader

Yes

 

Yes

no

no

1/8 Autoloader; Ultrium 232, 448, 960

Yes

 

Yes

no

no

MSL2024/4048 Tape Libraries

Yes

 

Yes

no

no

MSL6000 Tape Libraries

Yes

 

Yes

no

no

ESL E-Series Tape Libraries

Yes

 

Yes

no

no

VSL 6000 Virtual Library System

no

 

no

no

no

 

 

 

Cross Connect Table

2-Gbit Fibre Channel Adapter, single

2-Gbit Fibre Channel Adapter, dual

channel, PCI-X LP10000, FCA2684

channel, PCI-X LP10000, FCA2684DC

 

 

DS-A5132-AA

DS-A5134-AA

MSA30 Rack Disk & Tape Drive

 

no

no

Enclosure

 

 

 

 

 

 

4300 Rack Disk & Tape Drive

 

no

no

Enclosure

 

 

 

 

 

 

1U Rackmount Tape Drive Enclosure

 

no

no

3U Rackmount Tape Drive Enclosure

 

no

no

MSA1000 Storage System

 

Yes1

Yes1

HP StorageWorks Enterprise Virtual

 

Yes1

Yes1

Arrays; EVA4000; EVA6000; EVA8000

 

HP StorageWorks Disk Arrays;

 

Yes1

Yes1

xp10000; xp12000

 

DAT Tape Drives; 40; 72

 

Yes1

Yes1

DLT VS Tape Drives; 80; 160

 

Yes1

Yes1

1/8 Autoloader; Ultrium 232, 448, 960

 

Yes1

Yes1

SDLT Tape Drive; 320; 600

 

Yes1

Yes1

DAT 72/10 Autoloaders

 

Yes1

Yes1

 

 

 

 

 

DA - 11921 Worldwide — Version 24 — July 23, 2007

Page 27

Image 27
Contents QuickSpecs HP AlphaServer GS1280 Models 8HP AlphaServer GS1280 Model QuickSpecs At a Glance Cache Memory Boot/DiagnosticPower Supplies ProcessorQuickSpecs Requirements for Partitions Recommended ServicesRequirements System Requirements Optional PurchasesConfiguration Guidelines Licensing Systems for Both OpenVMS and Tru64 UnixQB-63PAQ-AC System Management Hardware/Software Requirements Select Base System MandatoryRacks Full Use CPU Building Supported ConfigurationsConfiguration and Use of instant Capacity iCAP CPUs CPU Building Block Modules MandatoryFirst USE ICAP EnablementICAP CPU Building Terms and DefinitionsOption Select Memory Options Mandatory Configuration GuidelinesMemory Application Examples CPUSystem I/O Expansion Mandatory Configuration Guidelines Memory SpecificationUSB ScsiDVD CD-RW Units Power Distribution Units MandatoryPower Distribution Type aDual AC Power Optional Type a PowerDistribution Units QuickSpecs Internal System Expansion Optional AlphaServer GS1280 Model 8 Internal System Expansion OptionsQuickSpecs QuickSpecs QuickSpecs ES/GS Common Options Contents Overall System Capacities for I/O Adapters and Controllers Calculated Maximum Throughput Bit data pathCalculated Maximum Throughput AGPMHz PCI-X/PCI slots in High Performance Drawers Per systemPCI-X/PCI slots in Standard I/O Drawers Maximum High Performance I/O Drawers FourStandard I/O Drawer used in ES47, ES80, and GS1280 Systems Adapters Installed Max Bus SpeedPCI 4X AGPSignal Voltage Adapters Installed Max Bus Speed Port Bus # Slot #To EV7 3X-KZPEA-DB 3X-KZPCA-AA 3X-KZPDC-BE/DF 3X-KZPEC-BF/DG U320 LVD ScsiMax Payload specd Vertical Rack CapacityRail Spacing Hole PatternRackmount Kits 3X-DEGXA-SR DescriptionEthernet Network Interface Cards 3X-DEGXA-TRAsynchronous Communications Network Interface Cards CCMFB-BA Memory Channel Optional Configuration GuidelinesMemory Channel Adapter CCMAB-BAMemory Channel Cipca Adapter Backplane RAID Scsi ControllersCables for Scsi and Backplane RAID Controllers Fibre Channel ControllersBus Model MSA30 Multi StorageWorks Enclosures for Disks and Tapes OptionalModel MSA30, Single Bus Model MSA30, Dual1000 HP StorageWorks Enterprise Virtual Array Disks OptionalDrives EVA8000Model EVA4000 EVA6000 EVA8000 HP StorageWorks Disk Array xp10000DLT VS External HP StorageWorks Sdlt Tape Drive FamilySdlt External HP StorageWorks DLT VS Tape Drive FamilyUltrium LTO External HP StorageWorks Ultrium LTO Tape Drive FamilyHP StorageWorks MSL2024 Tape Library HP StorageWorks 1/8 Tape Autoloader FamilyAutoloader Ultrium LTO Autoloader Rack Mount KitMSL6026 MSL6030 MSL6052 MSL6060 Form Factor Maximum DataTransfer native HP StorageWorks MSL6000 Tape LibrariesRack Maximum Capacity Configuration EML 103e EML 245e EML 442e EML 505e# of drives possible # of slots Product height withinCapacity Usable Capacity SwitchesVLS Raw Capacity Maximum RawOpenVMS Note CAT5e Cables Keyboard, Video, Mouse KVM SwitchesMonitors Configuration Guidelines Rackmount Keyboard/Drawer Keyboard/Monitor OptionsPanel Monitors Monitor Power CordsCarbon/Silver Monitors Carbon/Silver FlatGraphics Software Graphics AdaptersQA-6ADAA-H8 QA-6ADAA-GZOpenVMS Rules OpenVMS Galaxy Galaxy Soft PartitionSystem Codes for Hardware and Software Support Services OptionalService Part Numbers Program Features Principal Server HP Support PlusHP Proactive Critical ServicesHP O/S Program Features Additional ServicesInstallation Installation and StartupYT-VISIT-R1 ServiceBasic Integration YT-VISIT-B1Full Custom Clustering ServicePartitioning Service ConfigurationsGS1280 Conversion Kit AlphaServer GS1280, Upgrades for Single SystemsGS1280 Conversion Kit3X-BNPSB-03 3X-BNPSB-04 3X-BA65C-AA 3X-BA65D-AAPDU required for all GS1280 Models North America Japan Europe Power RequirementsPower Distribution Unit 3X-H7606-AA Power Distribution Unit 3X-H7606-BAModels 32 and 64 H7606-Bx Physical Characteristics Power Required, KvaPower Distribution Unit GS1280 Models 3X-H7606 Power Distribution UnitService Clearances-All Operating Models Environmental Operating Non-OperatingAcoustics Declared values per ISO 9296 and ISO