HP GS1280 manual Asynchronous Communications Network Interface Cards

Page 31

QuickSpecs

HP AlphaServer GS1280 Systems

ES/GS Common Options

Step 1b - Networks and Communications — Optional

Description

Device Type

 

Part Number

Maximum Quantity Tested & Supported

 

 

 

 

 

U=Tru64 UNIX

 

 

 

 

 

 

O=OpenVMS

 

 

 

 

 

 

L=Redhat V7.2 Linux

 

 

 

 

 

per system

per hard partition: per system

 

 

 

 

ES47

ES47

ES80

GS1280

 

 

 

 

Tower

 

 

 

 

 

 

 

Workstation

 

 

 

Synchronous Communications Network Interface Cards

 

 

 

 

 

Dual-port Intelligent Synchronous

PCI 3.3V,

 

3X-PBXDD-AA

4/U

4:8/U

4:16/U

4:128/U

Communications NIC; requires one or

32 b,

 

 

4/O

4:8/O

4:16/O

4:128/O

two BC3xx sync cables.

33 MHz

 

 

 

 

 

 

Quad-port Intelligent Synchronous

PCI 3.3V,

 

3X-PBXDD-AB

4/U

4:8/U

4:16/U

4:128/U

Communications NIC; requires one to

32 b,

 

 

4/O

4:8/O

4:16/O

4:128/O

four BC3xx sync cables.

33 MHz

 

 

 

 

 

 

Asynchronous Communications Network Interface Cards

4-port Async Communications NIC with DB-25 cable

PCI 3.3V,

32b,

33 MHz

PBXDA-BA

2/U

2/O

2:4/U

2:4/O

2:8/U

2:8/O

2:64/U

2:64/O

8-port Async Communications NIC

PCI 3.3V,

32b,

33 MHz

PBXDA-BB

2/U

2/O

2:4/U

2:4/O

2:8/U

2:8/O

2:64/U

2:64/O

16-port Async Communications Controller and rackmount 16-port distribution box with RJ45 connectors

PCI 3.3V,

32b,

33 MHz

PBXDA-AC

2/U

2/O

2:4/U

2:4/O

2:8/U

2:8/O

2:64/U

2:64/O

Cables for Ethernet, ATM, Synchronous, and Asynchronous Network Interface Cards

Multimode fiber optic (MMF) 62.5/125um duplex cable, with SC-to-SC

BN34B-xx

connectors. xx = 2E, 4E, 01, 03, 10, 20, 30 for 2.4, 4.5, 1, 3, 10, 20, and 30

 

meters

 

Category 5e (4-Unshielded Twisted Pairs / UTP) straight-through cable with

BN25G-xx

RJ45-to-RJ45 connectors for system to switch, repeater, or hub connectivity. xx

 

= 0B, 0E, 01, 03, 04, 07 for 0.2, 0.5, 1, 3, 4, and 7 meters

 

Category 5e (4-Twisted Pairs, Screened/ ScTP) straight-through cable with

BN26M-xx

RJ45-to-RJ45 connectors for system to switch, repeater, or hub connectivity. xx

 

= 0B, 0E, 01, 03, 04, 07 for 0.2, 0.5, 1, 3, 4, and 7 meters

 

Category 5e (4-Unshielded Twisted Pairs / UTP) Xover cable with RJ45-to-RJ45

BN24Q-xx

connectors for system to switch, repeater, or hub connectivity. xx = 0E, 01, 03,

 

04, 07 for 0.5, 1, 3, 4, and 7 meters

 

Category 5e (4-Twisted Pairs, Screened / ScTP) Xover cable with RJ45-to-RJ45

BN28Q-xx

connectors for system to switch, repeater, or hub connectivity. xx = 0E, 01, 03,

 

04, 07 for 0.5, 1, 3, 4, and 7 meters

 

EIA-530 Single-port synchronous cable

3X-BC34G-06

V.24/EIA-232 Single-port synchronous cable

3X-BC34L-06

V.11/x.21 Single-port synchronous cable

3X-BC33S-06

V.35 Single-port synchronous cable

3X-BC34T-06

RJ45-to-DB-25 Asynchronous Converter Cable

CXI01-AC

DA - 11921 Worldwide — Version 24 — July 23, 2007

Page 31

Image 31
Contents QuickSpecs HP AlphaServer GS1280 Models 8HP AlphaServer GS1280 Model QuickSpecs At a Glance Cache Memory Boot/DiagnosticPower Supplies ProcessorQuickSpecs Requirements for Partitions Recommended ServicesRequirements System Requirements Optional PurchasesLicensing Systems for Both OpenVMS and Tru64 Unix Configuration GuidelinesQB-63PAQ-AC Select Base System Mandatory System Management Hardware/Software RequirementsRacks Full Use CPU Building Supported ConfigurationsConfiguration and Use of instant Capacity iCAP CPUs CPU Building Block Modules MandatoryFirst USE ICAP EnablementICAP CPU Building Terms and DefinitionsOption Select Memory Options Mandatory Configuration GuidelinesMemory Application Examples CPUSystem I/O Expansion Mandatory Configuration Guidelines Memory SpecificationScsi USBDVD CD-RW Units Power Distribution Units MandatoryPower Distribution Type aType a Power Dual AC Power OptionalDistribution Units QuickSpecs Internal System Expansion Optional AlphaServer GS1280 Model 8 Internal System Expansion OptionsQuickSpecs QuickSpecs QuickSpecs ES/GS Common Options Contents Overall System Capacities for I/O Adapters and Controllers Calculated Maximum Throughput Bit data pathCalculated Maximum Throughput AGPMHz PCI-X/PCI slots in High Performance Drawers Per systemPCI-X/PCI slots in Standard I/O Drawers Maximum High Performance I/O Drawers FourStandard I/O Drawer used in ES47, ES80, and GS1280 Systems Adapters Installed Max Bus SpeedPCI 4X AGPPort Bus # Slot # Signal Voltage Adapters Installed Max Bus SpeedTo EV7 3X-KZPEA-DB 3X-KZPCA-AA 3X-KZPDC-BE/DF 3X-KZPEC-BF/DG U320 LVD ScsiMax Payload specd Vertical Rack CapacityRail Spacing Hole PatternRackmount Kits 3X-DEGXA-SR DescriptionEthernet Network Interface Cards 3X-DEGXA-TRAsynchronous Communications Network Interface Cards CCMFB-BA Memory Channel Optional Configuration GuidelinesMemory Channel Adapter CCMAB-BAMemory Channel Cipca Adapter Backplane RAID Scsi ControllersCables for Scsi and Backplane RAID Controllers Fibre Channel ControllersBus Model MSA30 Multi StorageWorks Enclosures for Disks and Tapes OptionalModel MSA30, Single Bus Model MSA30, Dual1000 HP StorageWorks Enterprise Virtual Array Disks OptionalDrives EVA8000Model EVA4000 EVA6000 EVA8000 HP StorageWorks Disk Array xp10000DLT VS External HP StorageWorks Sdlt Tape Drive FamilySdlt External HP StorageWorks DLT VS Tape Drive FamilyUltrium LTO External HP StorageWorks Ultrium LTO Tape Drive FamilyHP StorageWorks MSL2024 Tape Library HP StorageWorks 1/8 Tape Autoloader FamilyAutoloader Ultrium LTO Autoloader Rack Mount KitMSL6026 MSL6030 MSL6052 MSL6060 Form Factor Maximum DataTransfer native HP StorageWorks MSL6000 Tape LibrariesRack Maximum Capacity Configuration EML 103e EML 245e EML 442e EML 505e# of drives possible # of slots Product height withinCapacity Usable Capacity SwitchesVLS Raw Capacity Maximum RawOpenVMS Note CAT5e Cables Keyboard, Video, Mouse KVM SwitchesMonitors Configuration Guidelines Rackmount Keyboard/Drawer Keyboard/Monitor OptionsPanel Monitors Monitor Power CordsCarbon/Silver Monitors Carbon/Silver FlatGraphics Software Graphics AdaptersQA-6ADAA-GZ QA-6ADAA-H8OpenVMS Rules OpenVMS Galaxy Galaxy Soft PartitionSystem Codes for Hardware and Software Support Services OptionalService Part Numbers Program Features Principal Server HP Support PlusHP Proactive Critical ServicesHP O/S Program Features Additional ServicesInstallation Installation and StartupYT-VISIT-R1 ServiceBasic Integration YT-VISIT-B1Full Custom Clustering ServicePartitioning Service ConfigurationsGS1280 Conversion Kit AlphaServer GS1280, Upgrades for Single SystemsGS1280 Conversion Kit3X-BNPSB-03 3X-BNPSB-04 3X-BA65C-AA 3X-BA65D-AAPDU required for all GS1280 Models North America Japan Europe Power RequirementsPower Distribution Unit 3X-H7606-AA Power Distribution Unit 3X-H7606-BAModels 32 and 64 H7606-Bx Physical Characteristics Power Required, KvaPower Distribution Unit GS1280 Models 3X-H7606 Power Distribution UnitEnvironmental Operating Non-Operating Service Clearances-All Operating ModelsAcoustics Declared values per ISO 9296 and ISO