HP GS1280 VLS Raw Capacity, Maximum Raw, Capacity Usable Capacity, Maximum Usable, Channel Ports

Page 43

QuickSpecs

HP AlphaServer GS1280 Systems

ES/GS Common Options

 

VLS 6105

VLS 6109

VLS 6510

 

VLS 6518

VLS 6840

VLS 6870

Raw Capacity

3TB

6TB

6TB

 

12TB

12TB

24TB

Maximum Raw

6TB

12 TB

12TB

 

24TB

48TB

96TB

Capacity

 

 

 

 

 

 

 

 

Usable Capacity

2.5TB

4.4 TB

5TB

 

8.8TB

10TB

17.6TB

Maximum Usable

5TB

8.8TB

10TB

 

17.6TB

40TB

70.4TB

Capacity

 

 

 

 

 

 

 

 

Interface - 2Gb Fibre

Two

Two

Four

 

Four

Four

Four

Channel Ports

 

 

 

 

 

 

 

 

(LC connectors, auto-

 

 

 

 

 

 

 

 

negotiating)

 

 

 

 

 

 

 

 

Step 9 – Storage Network Switches, Hubs, and Interconnects — Optional

 

 

 

 

 

 

 

Network Storage

Network Storage Routers enable multiple host servers to communicate with a SCSI tape device

Routers

over a Fibre Channel link.

 

 

 

 

 

 

 

For configuration details, see the Switches, Hubs, and Interconnects QuickSpecs at:

 

http://www.compaq.com/products/quickspecs/North_America/10490.html

 

 

 

 

 

Fibre Channel

HP supports three product lines of Fibre Channel switch products that may be used to build SAN

Switches

fabrics. Each product line provides certain advantages that apply to specific applications. For

 

more information on specific switch models and selection, please refer to Part II in the SAN

 

Design Guidelines referenced on the SAN Infrastructure page:

 

 

 

 

http://h18006.www1.hp.com/storage/saninfrastructure/index.html

 

 

 

The B-Series product line includes a wide range of Fibre Channel switches, described as "SAN switches" and "Core switches." Products in this family include switches from the HP StorageWorks SAN Switch 2/16 to the HP StorageWorks Core Switch 2/64. This product line includes switches with 8, 16, 32, and 64 ports, including both full-function and entry-level models. The HP StorageWorks Core Switch 2/64 includes a pair of independent 64-port switches in a single chassis with a high level internal redundancy.

The C-Series product line includes the Cisco MDS 9506 and 9509 Multilayer Directors and the Cisco MDS 9216, 9120, and 9140 Multilayer Fabric Switches. The MDS 9506 is supported with 224 ports, over seven modular chassis consisting of both 16-port and 32-port modules. The MDS 9506 is supported with 128 ports, over four modular chassis consisting of both 16-port and 32-port modules. The MDS 9216 has a basic configuration with 16 ports. It has an expansion slot that supports either a 16- or a 32-port card, for 32 or 48 ports in total.

The M-Series Fabric product line includes a wide range of Fibre Channel switches described as "Directors" and "Edge switches." A partial list of products in this family includes the HP StorageWorks Director 2/140 and the HP StorageWorks Edge Switch 2/32. This product line includes switches with 16, 24, 32, 64, and 140 ports internal microcode. The HP StorageWorks Director 2/64 and 2/140 switches have a high level of internal redundancy.

DA - 11921 Worldwide — Version 24 — July 23, 2007

Page 43

Image 43
Contents QuickSpecs HP AlphaServer GS1280 Models 8HP AlphaServer GS1280 Model QuickSpecs At a Glance Cache Memory Boot/DiagnosticPower Supplies ProcessorQuickSpecs Requirements for Partitions Recommended ServicesRequirements System Requirements Optional PurchasesLicensing Systems for Both OpenVMS and Tru64 Unix Configuration GuidelinesQB-63PAQ-AC Select Base System Mandatory System Management Hardware/Software RequirementsRacks Full Use CPU Building Supported ConfigurationsConfiguration and Use of instant Capacity iCAP CPUs CPU Building Block Modules MandatoryFirst USE ICAP EnablementICAP CPU Building Terms and DefinitionsOption Select Memory Options Mandatory Configuration GuidelinesMemory Application Examples CPUSystem I/O Expansion Mandatory Configuration Guidelines Memory SpecificationScsi USBDVD CD-RW Units Power Distribution Units MandatoryPower Distribution Type aType a Power Dual AC Power OptionalDistribution Units QuickSpecs Internal System Expansion Optional AlphaServer GS1280 Model 8 Internal System Expansion OptionsQuickSpecs QuickSpecs QuickSpecs ES/GS Common Options Contents Overall System Capacities for I/O Adapters and Controllers Calculated Maximum Throughput Bit data pathCalculated Maximum Throughput AGPMHz PCI-X/PCI slots in High Performance Drawers Per systemPCI-X/PCI slots in Standard I/O Drawers Maximum High Performance I/O Drawers FourStandard I/O Drawer used in ES47, ES80, and GS1280 Systems Adapters Installed Max Bus SpeedPCI 4X AGPPort Bus # Slot # Signal Voltage Adapters Installed Max Bus SpeedTo EV7 3X-KZPEA-DB 3X-KZPCA-AA 3X-KZPDC-BE/DF 3X-KZPEC-BF/DG U320 LVD ScsiMax Payload specd Vertical Rack CapacityRail Spacing Hole PatternRackmount Kits 3X-DEGXA-SR DescriptionEthernet Network Interface Cards 3X-DEGXA-TRAsynchronous Communications Network Interface Cards CCMFB-BA Memory Channel Optional Configuration GuidelinesMemory Channel Adapter CCMAB-BAMemory Channel Cipca Adapter Backplane RAID Scsi ControllersCables for Scsi and Backplane RAID Controllers Fibre Channel ControllersBus Model MSA30 Multi StorageWorks Enclosures for Disks and Tapes OptionalModel MSA30, Single Bus Model MSA30, Dual1000 HP StorageWorks Enterprise Virtual Array Disks OptionalDrives EVA8000Model EVA4000 EVA6000 EVA8000 HP StorageWorks Disk Array xp10000DLT VS External HP StorageWorks Sdlt Tape Drive FamilySdlt External HP StorageWorks DLT VS Tape Drive FamilyUltrium LTO External HP StorageWorks Ultrium LTO Tape Drive FamilyHP StorageWorks MSL2024 Tape Library HP StorageWorks 1/8 Tape Autoloader FamilyAutoloader Ultrium LTO Autoloader Rack Mount KitMSL6026 MSL6030 MSL6052 MSL6060 Form Factor Maximum DataTransfer native HP StorageWorks MSL6000 Tape LibrariesRack Maximum Capacity Configuration EML 103e EML 245e EML 442e EML 505e# of drives possible # of slots Product height withinCapacity Usable Capacity SwitchesVLS Raw Capacity Maximum RawOpenVMS Note CAT5e Cables Keyboard, Video, Mouse KVM SwitchesMonitors Configuration Guidelines Rackmount Keyboard/Drawer Keyboard/Monitor OptionsPanel Monitors Monitor Power CordsCarbon/Silver Monitors Carbon/Silver FlatGraphics Software Graphics AdaptersQA-6ADAA-GZ QA-6ADAA-H8OpenVMS Rules OpenVMS Galaxy Galaxy Soft PartitionSystem Codes for Hardware and Software Support Services OptionalService Part Numbers Program Features Principal Server HP Support PlusHP Proactive Critical ServicesHP O/S Program Features Additional ServicesInstallation Installation and StartupYT-VISIT-R1 ServiceBasic Integration YT-VISIT-B1Full Custom Clustering ServicePartitioning Service ConfigurationsGS1280 Conversion Kit AlphaServer GS1280, Upgrades for Single SystemsGS1280 Conversion Kit3X-BNPSB-03 3X-BNPSB-04 3X-BA65C-AA 3X-BA65D-AAPDU required for all GS1280 Models North America Japan Europe Power RequirementsPower Distribution Unit 3X-H7606-AA Power Distribution Unit 3X-H7606-BAModels 32 and 64 H7606-Bx Physical Characteristics Power Required, KvaPower Distribution Unit GS1280 Models 3X-H7606 Power Distribution UnitEnvironmental Operating Non-Operating Service Clearances-All Operating ModelsAcoustics Declared values per ISO 9296 and ISO