HP GS1280 manual Configuration Guidelines, Licensing Systems for Both OpenVMS and Tru64 Unix

Page 8

QuickSpecs

HP AlphaServer GS1280 Systems

Systems

1.One Dual CPU Building Block Module (Step 3)

2.Memory (Step 4)

3.I/O Drawer (Step 5)

a.One Standard I/O Drawer (Master or Expansion), or

b.Shared (up to four hard partitions) access to one High Performance I/O Drawer (Master or Expansion)

4.One local disk (Step 5) or external storage for the system software. Network boot can be used in place of the disk storage.

5.User access via the USB port in a Master I/O Drawer, a network connection (requires a LAN or WAN I/O adapter), or local terminal (requires an async I/O adapter).

6.All systems require the following minimum firmware and software revisions to run hard partitions:

a.Minimum Firmware console rev: V6.5-8

b.Tru64 UNIX: V5.1B + Patch kit - T64V51BB22AS0002-20030415.tar

c.OpenVMS: V7.3-1 + TIMA Kits (available at http://h18003.www1.hp.com/alphaserver/gs1280/gs1280_tech.html):

i.DEC-AVPVMS-VMS731_PARTITIONING-V0100-4.PCSI

ii.AVPVMS-VMS731_PARTITIONING-V0100_CVRLET

iii.AVPVMS-VMS731_PARTITIONING-V0100_SUBFORM

Configuration Guidelines

1.The two processors on a Dual Processor CPU Module cannot be split between hard partitions.

2.The set of processors assigned to a partition must form a continuous rectangle on the system interconnect mesh network.

3.CPU modules in an 8P Building Block Drawer share the same 48v power feed (from a redundant power supply). If the 8P Building Block Drawer contains all or portions of several hard partitions, a power fault in the drawer could affect all the partitions in that drawer. Hard partitions that consist of whole 8P Building Block Drawers limit the risk of a power fault in one drawer to one partition.

4.Base systems include an operating system license (Tru64 UNIX or OpenVMS) that licenses all hardware partitions of the system.

5.The license for an HP software product, the license(s) and license key(s) that represent those licenses, may be applied to any partition (OpenVMS Galaxy instance or hardware partition) within that system. Different versions of the operating system or layered products may be used on different partitions. In this case, the customer must be licensed for the latest version in use. Software products from other suppliers may have different licensing requirements for partitions.

Step 1c - Licensing Systems for Both OpenVMS and Tru64 UNIX

A System requires licenses for both OpenVMS and Tru64 UNIX operating systems, either for dual O/S boot of the entire system or for different operating systems in separate hard partitions. To use a second operating system, order the appropriate base system upgrade license and as many dual CPU SMP licenses as needed.

OpenVMS software base system upgrade for GS1280

QB-63PAQ-AC

Tru64 UNIX software base system upgrade for GS1280

QB-595AN-AB

OpenVMS Alpha dual CPU SMP license for GS1280

QL-MT1A9-6T

Tru64 UNIX Alpha dual CPU SMP license for GS1280

QL-MT4A9-6T

 

 

DA - 11921 Worldwide — Version 24 — July 23, 2007

Page 8

Image 8
Contents HP AlphaServer GS1280 Models 8 QuickSpecsHP AlphaServer GS1280 Model QuickSpecs At a Glance Boot/Diagnostic Power Supplies Processor Cache MemoryQuickSpecs Recommended Services Requirements System RequirementsOptional Purchases Requirements for PartitionsQB-63PAQ-AC Configuration GuidelinesLicensing Systems for Both OpenVMS and Tru64 Unix Racks System Management Hardware/Software RequirementsSelect Base System Mandatory Supported Configurations Configuration and Use of instant Capacity iCAP CPUsCPU Building Block Modules Mandatory Full Use CPU BuildingICAP Enablement ICAP CPU BuildingTerms and Definitions First USESelect Memory Options Mandatory Configuration Guidelines Memory Application ExamplesCPU OptionMemory Specification System I/O Expansion Mandatory Configuration GuidelinesDVD CD-RW USBScsi Power Distribution Units Mandatory Power DistributionType a UnitsDistribution Units Dual AC Power OptionalType a Power QuickSpecs AlphaServer GS1280 Model 8 Internal System Expansion Options Internal System Expansion OptionalQuickSpecs QuickSpecs QuickSpecs ES/GS Common Options Contents Calculated Maximum Throughput Bit data path Calculated Maximum ThroughputAGP Overall System Capacities for I/O Adapters and ControllersPer system PCI-X/PCI slots in Standard I/O DrawersMaximum High Performance I/O Drawers Four MHz PCI-X/PCI slots in High Performance DrawersAdapters Installed Max Bus Speed PCI4X AGP Standard I/O Drawer used in ES47, ES80, and GS1280 SystemsTo EV7 Signal Voltage Adapters Installed Max Bus SpeedPort Bus # Slot # U320 LVD Scsi 3X-KZPEA-DB 3X-KZPCA-AA 3X-KZPDC-BE/DF 3X-KZPEC-BF/DGVertical Rack Capacity Rail SpacingHole Pattern Max Payload specdRackmount Kits Description Ethernet Network Interface Cards3X-DEGXA-TR 3X-DEGXA-SRAsynchronous Communications Network Interface Cards Memory Channel Optional Configuration Guidelines Memory Channel AdapterCCMAB-BA CCMFB-BAMemory Channel Backplane RAID Scsi Controllers Cables for Scsi and Backplane RAID ControllersFibre Channel Controllers Cipca AdapterStorageWorks Enclosures for Disks and Tapes Optional Model MSA30, SingleBus Model MSA30, Dual Bus Model MSA30 MultiDisks Optional 1000 HP StorageWorks Enterprise Virtual ArrayEVA8000 Model EVA4000 EVA6000 EVA8000HP StorageWorks Disk Array xp10000 DrivesHP StorageWorks Sdlt Tape Drive Family Sdlt ExternalHP StorageWorks DLT VS Tape Drive Family DLT VS ExternalHP StorageWorks Ultrium LTO Tape Drive Family Ultrium LTO ExternalHP StorageWorks 1/8 Tape Autoloader Family Autoloader Ultrium LTOAutoloader Rack Mount Kit HP StorageWorks MSL2024 Tape LibraryMaximum Data Transfer nativeHP StorageWorks MSL6000 Tape Libraries MSL6026 MSL6030 MSL6052 MSL6060 Form FactorConfiguration EML 103e EML 245e EML 442e EML 505e # of drives possible # of slotsProduct height within Rack Maximum CapacitySwitches VLS Raw CapacityMaximum Raw Capacity Usable CapacityOpenVMS Note Keyboard, Video, Mouse KVM Switches Monitors Configuration GuidelinesRackmount Keyboard/Drawer Keyboard/Monitor Options CAT5e CablesMonitor Power Cords Carbon/Silver MonitorsCarbon/Silver Flat Panel MonitorsGraphics Adapters Graphics SoftwareOpenVMS QA-6ADAA-H8QA-6ADAA-GZ OpenVMS Galaxy Galaxy Soft Partition RulesHardware and Software Support Services Optional Service Part NumbersProgram Features Principal Server HP Support Plus System Codes forCritical Services HP ProactiveProgram Features Additional Services InstallationInstallation and Startup HP O/SService Basic IntegrationYT-VISIT-B1 YT-VISIT-R1Clustering Service Partitioning ServiceConfigurations Full CustomAlphaServer GS1280, Upgrades for Single Systems GS1280 ConversionKit GS1280 Conversion Kit3X-BA65C-AA 3X-BA65D-AA 3X-BNPSB-03 3X-BNPSB-04North America Japan Europe Power Requirements Power Distribution Unit 3X-H7606-AAPower Distribution Unit 3X-H7606-BA PDU required for all GS1280 ModelsPower Required, Kva Power Distribution UnitGS1280 Models 3X-H7606 Power Distribution Unit Models 32 and 64 H7606-Bx Physical CharacteristicsAcoustics Declared values per ISO 9296 and ISO Service Clearances-All Operating ModelsEnvironmental Operating Non-Operating