HP GS1280 manual 3X-BA65C-AA 3X-BA65D-AA, 3X-BNPSB-03 3X-BNPSB-04

Page 56

QuickSpecs

HP AlphaServer GS1280 Systems

Upgrades

GS1280 Model 16 to Model 32 Upgrade Kit

GS1280 Model 32 to Model 64 Upgrade Kit

System expansion hardware to upgrade an AlphaServer GS1280 Model 16 to an AlphaServer GS1280 Model 32. Includes:

One CPU rack with four 8P System drawers

One power rack.

Installation involves transfer of CPU modules, I/O Drawers and storage from original M16 rack to new Upgrade racks (any new CPU modules and drawers ordered with the Upgrade are integrated at the factory).

NOTE: Upgrade order must conform to configuration requirements for a GS1280 Model 32 system (see Configuration starting at Step 3), with:

At least one Dual CPU Module One I/O Master Drawer

Power Distribution Units - see Step 6 for description of choices.

System expansion hardware to upgrade an AlphaServer GS1280 Model 32 to an AlphaServer GS1280 Model 64. Includes:

One CPU rack with four 8P System drawers One power rack.

Cable Kit to convert two AlphaServer GS1280 Model 32 systems to one AlphaServer GS1280 Model 64 system.

NOTE: Upgrade order must conform to configuration requirements for a GS1280 Model 32 system (see Configuration starting at Step 3), with:

At least one Dual CPU Module One I/O Master Drawer

Power Distribution Units - see Step 6 for description of choices.

Final configuration of the GS1280 Model 32 to Model 64 Upgrade combined with the existing GS1280 M32 must conform to configuration requirements for a GS1280 Model 64 system (see Configuration starting at Step 3).

3X-BA65C-AA

3X-BA65D-AA

AlphaServer GS1280, Conversion for Two Systems

GS1280 Conversion Kit; two Model 16s to Model 32

GS1280 Conversion Kit; two Model 32s to Model 64

Cable Kit to convert two AlphaServer GS1280 Model 16 systems to one AlphaServer GS1280 Model 32 system.

NOTE: Mechanical configuration of the GS1280 M32 consists of two side-by- side CPU & Power combination racks. This configuration is not upgradeable to a GS1280 Model 64.

Cable Kit to convert two AlphaServer GS1280 Model 32 systems to one AlphaServer GS1280 Model 64 system.

3X-BNPSB-03

3X-BNPSB-04

DA - 11921 Worldwide — Version 24 — July 23, 2007

Page 56

Image 56
Contents HP AlphaServer GS1280 Models 8 QuickSpecsHP AlphaServer GS1280 Model QuickSpecs At a Glance Boot/Diagnostic Power SuppliesProcessor Cache MemoryQuickSpecs Recommended Services Requirements System RequirementsOptional Purchases Requirements for PartitionsQB-63PAQ-AC Configuration GuidelinesLicensing Systems for Both OpenVMS and Tru64 Unix Racks System Management Hardware/Software RequirementsSelect Base System Mandatory Supported Configurations Configuration and Use of instant Capacity iCAP CPUsCPU Building Block Modules Mandatory Full Use CPU BuildingICAP Enablement ICAP CPU BuildingTerms and Definitions First USESelect Memory Options Mandatory Configuration Guidelines Memory Application ExamplesCPU OptionMemory Specification System I/O Expansion Mandatory Configuration GuidelinesDVD CD-RW USBScsi Power Distribution Units Mandatory Power DistributionType a UnitsDistribution Units Dual AC Power OptionalType a Power QuickSpecs AlphaServer GS1280 Model 8 Internal System Expansion Options Internal System Expansion OptionalQuickSpecs QuickSpecs QuickSpecs ES/GS Common Options Contents Calculated Maximum Throughput Bit data path Calculated Maximum ThroughputAGP Overall System Capacities for I/O Adapters and ControllersPer system PCI-X/PCI slots in Standard I/O DrawersMaximum High Performance I/O Drawers Four MHz PCI-X/PCI slots in High Performance DrawersAdapters Installed Max Bus Speed PCI4X AGP Standard I/O Drawer used in ES47, ES80, and GS1280 SystemsTo EV7 Signal Voltage Adapters Installed Max Bus SpeedPort Bus # Slot # U320 LVD Scsi 3X-KZPEA-DB 3X-KZPCA-AA 3X-KZPDC-BE/DF 3X-KZPEC-BF/DGVertical Rack Capacity Rail SpacingHole Pattern Max Payload specdRackmount Kits Description Ethernet Network Interface Cards3X-DEGXA-TR 3X-DEGXA-SRAsynchronous Communications Network Interface Cards Memory Channel Optional Configuration Guidelines Memory Channel AdapterCCMAB-BA CCMFB-BAMemory Channel Backplane RAID Scsi Controllers Cables for Scsi and Backplane RAID ControllersFibre Channel Controllers Cipca AdapterStorageWorks Enclosures for Disks and Tapes Optional Model MSA30, SingleBus Model MSA30, Dual Bus Model MSA30 MultiDisks Optional 1000 HP StorageWorks Enterprise Virtual ArrayEVA8000 Model EVA4000 EVA6000 EVA8000HP StorageWorks Disk Array xp10000 DrivesHP StorageWorks Sdlt Tape Drive Family Sdlt ExternalHP StorageWorks DLT VS Tape Drive Family DLT VS ExternalHP StorageWorks Ultrium LTO Tape Drive Family Ultrium LTO ExternalHP StorageWorks 1/8 Tape Autoloader Family Autoloader Ultrium LTOAutoloader Rack Mount Kit HP StorageWorks MSL2024 Tape LibraryMaximum Data Transfer nativeHP StorageWorks MSL6000 Tape Libraries MSL6026 MSL6030 MSL6052 MSL6060 Form FactorConfiguration EML 103e EML 245e EML 442e EML 505e # of drives possible # of slotsProduct height within Rack Maximum CapacitySwitches VLS Raw CapacityMaximum Raw Capacity Usable CapacityOpenVMS Note Keyboard, Video, Mouse KVM Switches Monitors Configuration GuidelinesRackmount Keyboard/Drawer Keyboard/Monitor Options CAT5e CablesMonitor Power Cords Carbon/Silver MonitorsCarbon/Silver Flat Panel MonitorsGraphics Adapters Graphics SoftwareOpenVMS QA-6ADAA-H8QA-6ADAA-GZ OpenVMS Galaxy Galaxy Soft Partition RulesHardware and Software Support Services Optional Service Part NumbersProgram Features Principal Server HP Support Plus System Codes forCritical Services HP ProactiveProgram Features Additional Services InstallationInstallation and Startup HP O/SService Basic IntegrationYT-VISIT-B1 YT-VISIT-R1Clustering Service Partitioning ServiceConfigurations Full CustomAlphaServer GS1280, Upgrades for Single Systems GS1280 ConversionKit GS1280 Conversion Kit3X-BA65C-AA 3X-BA65D-AA 3X-BNPSB-03 3X-BNPSB-04North America Japan Europe Power Requirements Power Distribution Unit 3X-H7606-AAPower Distribution Unit 3X-H7606-BA PDU required for all GS1280 ModelsPower Required, Kva Power Distribution UnitGS1280 Models 3X-H7606 Power Distribution Unit Models 32 and 64 H7606-Bx Physical CharacteristicsAcoustics Declared values per ISO 9296 and ISO Service Clearances-All Operating ModelsEnvironmental Operating Non-Operating