HP GS1280 manual Adapters Installed Max Bus Speed, Pci, 4X AGP

Page 25

QuickSpecs

HP AlphaServer GS1280 Systems

ES/GS Common Options

For PCI-X capable slots:

All universal or 3.3V PCI and PCI-X cards are supported,

EXCEPT: UltraSCSI wide differential adapter, 32-bit/33-MHz PCI adapter (3X-KZPBA-CC)

PCI-X protocol is used on the bus, but reverts to PCI protocol in these cases:

When one or more PCI cards are in a bus segment

Gigabit Ethernet, Rev A (DEGXA-SA/TA) is in the bus segment

An I/O bus segment will operate at the least common denominator of the adapters installed or the lower speeds dictated by bus loading (as shown in the tables), whichever is less.

The PCI-X card slots must be populated contiguously starting with slot 1; otherwise the bus will run at 33 MHz PCI.

2P Building Block Drawer Slot Specifications

 

 

 

 

Bus Loading,

 

Port (Bus) #

Slot #

Maximum Bus Speed

Signal Voltage

Adapters Installed

Max Bus Speed

(contiguously starting

 

 

 

 

 

 

 

 

 

with Slot 1)

 

0

1

133 MHz

3.3V

1 PCI

66 MHz

 

1 PCI-X

133 MHz

 

 

 

 

1

1

66 MHz

3.3V

1 or 2 PCI

66 MHz

 

2

66 MHz

3.3V

 

3 or 4 PCI

50 MHz

 

3

66 MHz

3.3V

 

1 to 4 PCI-X

66 MHz

 

4

66 MHz

3.3V

 

 

 

3

1

4X AGP

1.5V

1 AGP

4X

Standard I/O Drawer used in ES47, ES80, and GS1280 Systems

For PCI-X capable slots:

All universal or 3.3V PCI and PCI-X cards are supported,

EXCEPT: UltraSCSI wide differential adapter, 32-bit/33-MHz PCI adapter (3X-KZPBA-CC) PCI-X protocol is used on the bus, but reverts to PCI protocol in these cases:

When one or more PCI cards are in a bus segment

With more than five (5) cards in a bus segment

Gigabit Ethernet, Rev A (DEGXA-SA/TA) is in the bus segment PCI 5V slots support ONLY:

For cluster support, CI host bus adapter (CIPCA-BA)

A legacy UltraSCSI wide differential adapter 32-bit/33-MHz PCI adapter (3X-KZPBA-CC)

An I/O bus segment will operate at the least common denominator of the adapters installed or the lower speeds dictated by bus loading (as shown in the tables), whichever is less.

The PCI-X card slots must be populated contiguously starting with slot 1; otherwise the bus will run at 33-MHz PCI.

DA - 11921 Worldwide — Version 24 — July 23, 2007

Page 25

Image 25
Contents QuickSpecs HP AlphaServer GS1280 Models 8HP AlphaServer GS1280 Model QuickSpecs At a Glance Power Supplies Boot/DiagnosticProcessor Cache MemoryQuickSpecs Requirements System Requirements Recommended ServicesOptional Purchases Requirements for PartitionsLicensing Systems for Both OpenVMS and Tru64 Unix Configuration GuidelinesQB-63PAQ-AC Select Base System Mandatory System Management Hardware/Software RequirementsRacks Configuration and Use of instant Capacity iCAP CPUs Supported ConfigurationsCPU Building Block Modules Mandatory Full Use CPU BuildingICAP CPU Building ICAP EnablementTerms and Definitions First USEMemory Application Examples Select Memory Options Mandatory Configuration GuidelinesCPU OptionSystem I/O Expansion Mandatory Configuration Guidelines Memory SpecificationScsi USBDVD CD-RW Power Distribution Power Distribution Units MandatoryType a UnitsType a Power Dual AC Power OptionalDistribution Units QuickSpecs Internal System Expansion Optional AlphaServer GS1280 Model 8 Internal System Expansion OptionsQuickSpecs QuickSpecs QuickSpecs ES/GS Common Options Contents Calculated Maximum Throughput Calculated Maximum Throughput Bit data pathAGP Overall System Capacities for I/O Adapters and ControllersPCI-X/PCI slots in Standard I/O Drawers Per systemMaximum High Performance I/O Drawers Four MHz PCI-X/PCI slots in High Performance DrawersPCI Adapters Installed Max Bus Speed4X AGP Standard I/O Drawer used in ES47, ES80, and GS1280 SystemsPort Bus # Slot # Signal Voltage Adapters Installed Max Bus SpeedTo EV7 3X-KZPEA-DB 3X-KZPCA-AA 3X-KZPDC-BE/DF 3X-KZPEC-BF/DG U320 LVD ScsiRail Spacing Vertical Rack CapacityHole Pattern Max Payload specdRackmount Kits Ethernet Network Interface Cards Description3X-DEGXA-TR 3X-DEGXA-SRAsynchronous Communications Network Interface Cards Memory Channel Adapter Memory Channel Optional Configuration GuidelinesCCMAB-BA CCMFB-BAMemory Channel Cables for Scsi and Backplane RAID Controllers Backplane RAID Scsi ControllersFibre Channel Controllers Cipca AdapterModel MSA30, Single StorageWorks Enclosures for Disks and Tapes OptionalBus Model MSA30, Dual Bus Model MSA30 Multi1000 HP StorageWorks Enterprise Virtual Array Disks OptionalModel EVA4000 EVA6000 EVA8000 EVA8000HP StorageWorks Disk Array xp10000 DrivesSdlt External HP StorageWorks Sdlt Tape Drive FamilyHP StorageWorks DLT VS Tape Drive Family DLT VS ExternalUltrium LTO External HP StorageWorks Ultrium LTO Tape Drive FamilyAutoloader Ultrium LTO HP StorageWorks 1/8 Tape Autoloader FamilyAutoloader Rack Mount Kit HP StorageWorks MSL2024 Tape LibraryTransfer native Maximum DataHP StorageWorks MSL6000 Tape Libraries MSL6026 MSL6030 MSL6052 MSL6060 Form Factor# of drives possible # of slots Configuration EML 103e EML 245e EML 442e EML 505eProduct height within Rack Maximum CapacityVLS Raw Capacity SwitchesMaximum Raw Capacity Usable CapacityOpenVMS Note Monitors Configuration Guidelines Keyboard, Video, Mouse KVM SwitchesRackmount Keyboard/Drawer Keyboard/Monitor Options CAT5e CablesCarbon/Silver Monitors Monitor Power CordsCarbon/Silver Flat Panel MonitorsGraphics Software Graphics AdaptersQA-6ADAA-GZ QA-6ADAA-H8OpenVMS Rules OpenVMS Galaxy Galaxy Soft PartitionService Part Numbers Hardware and Software Support Services OptionalProgram Features Principal Server HP Support Plus System Codes forHP Proactive Critical ServicesInstallation Program Features Additional ServicesInstallation and Startup HP O/SBasic Integration ServiceYT-VISIT-B1 YT-VISIT-R1Partitioning Service Clustering ServiceConfigurations Full CustomGS1280 Conversion AlphaServer GS1280, Upgrades for Single SystemsKit GS1280 Conversion Kit3X-BNPSB-03 3X-BNPSB-04 3X-BA65C-AA 3X-BA65D-AAPower Distribution Unit 3X-H7606-AA North America Japan Europe Power RequirementsPower Distribution Unit 3X-H7606-BA PDU required for all GS1280 ModelsPower Distribution Unit Power Required, KvaGS1280 Models 3X-H7606 Power Distribution Unit Models 32 and 64 H7606-Bx Physical CharacteristicsEnvironmental Operating Non-Operating Service Clearances-All Operating ModelsAcoustics Declared values per ISO 9296 and ISO