HP GS1280 manual Model EVA4000 EVA6000 EVA8000, HP StorageWorks Disk Array xp10000, Drives

Page 37

QuickSpecs

HP AlphaServer GS1280 Systems

ES/GS Common Options

 

 

 

 

EVA8000

Model

EVA4000

EVA6000

EVA8000

with expansion

 

 

 

 

cabinet

Drive Interface

Dual ported

Dual ported

Dual ported

Dual ported

 

2 Gb/s FC-AL

2 Gb/s FC-AL

2 Gb/s FC-AL

2 Gb/s FC-AL

Cache per controller pair

4GB

4GB

8GB

8GB

Host ports

Four 2 Gb/s FC

Four 2 Gb/s FC

Eight 2 Gb/s FC

Eight 2 Gb/s FC

Device ports

Four 2 Gb/s

Four 2 Gb/s

Eight 2 Gb/s

Eight 2 Gb/s

 

FC-AL

FC-AL

FC-AL

FC-AL

Device FC-AL switches

0

2

4

4

Maximum Drives per

56

112

168

240

model

 

 

 

 

HP StorageWorks Disk Array xp10000

The HP StorageWorks Disk Array xp1000 is an enterprise storage system that supports up to 240 Fibre Channel disk drives with up to 69 TB of capacity. The xp10000 supports up to 48 Fiber Channel (2-Gb or 4-Gb) interface connections.

See HP StorageWorks Disk Array xp10000 Product Information for configuration details:

http://h18000.www1.hp.com/products/quickspecs/12275_div/12275_div.HTML

HP StorageWorks Disk Array xp12000

The HP StorageWorks Disk Array xp12000 is an enterprise storage system that supports up to 1152 Fibre Channel disk drives with up to 332 TB of capacity. The xp12000 supports up to 128 Fiber Channel (2-Gb or 4-Gb) interface connections. See HP StorageWorks Disk Array xp12000 QuickSpecs for configuration details: http://h18006.www1.hp.com/products/quickspecs/12072_div/12072_div.html

Step 7 – Tape Drives — Optional

HP StorageWorks DAT Tape Drive Family

The HP StorageWorks DAT Tape Drives are an entry-level solution for small to medium server storage backup needs. The DAT Tape Drives have backwards compatibility with previous DDS technologies.

See HP StorageWorks DAT Drives QuickSpecs for configuration details:

http://h18000.www1.hp.com/products/quickspecs/11883_div/11883_div.HTML

DAT Hot-Plug Tape

40-GB hot-plug DAT tape drive, uses two Universal storage device slots

3R-A4745-AA

Drives

 

or Q1546A

(for use in StorageWorks

 

 

MSA30 and 4300

72-GB hot-plug DAT tape drive, uses two Universal storage device slots

3R-A4547-AA

Enclosures; and

 

or Q1529A

ES47/80 2P System

 

 

 

Drawer)

 

 

DAT Internal Tape

40-GB internal DAT tape drive, half-height device (carbon)

3R-A6831-AA

Drives

 

or C5686C

(for use in Rackmount

72-GB internal DAT tape drive, half-height device (carbon)

3R-A6663-AA

Tape Drive Enclosures)

 

or Q1522B

 

 

DAT External

40-GB external (tabletop) DAT tape drive

C5687D

(tabletop)Tape Drives

72-GB external (tabletop) DAT tape drive

Q1523B

 

DA - 11921 Worldwide — Version 24 — July 23, 2007

Page 37

Image 37
Contents QuickSpecs HP AlphaServer GS1280 Models 8HP AlphaServer GS1280 Model QuickSpecs At a Glance Power Supplies Boot/DiagnosticProcessor Cache MemoryQuickSpecs Requirements System Requirements Recommended ServicesOptional Purchases Requirements for PartitionsLicensing Systems for Both OpenVMS and Tru64 Unix Configuration GuidelinesQB-63PAQ-AC Select Base System Mandatory System Management Hardware/Software RequirementsRacks Configuration and Use of instant Capacity iCAP CPUs Supported ConfigurationsCPU Building Block Modules Mandatory Full Use CPU BuildingICAP CPU Building ICAP EnablementTerms and Definitions First USEMemory Application Examples Select Memory Options Mandatory Configuration GuidelinesCPU OptionSystem I/O Expansion Mandatory Configuration Guidelines Memory SpecificationScsi USBDVD CD-RW Power Distribution Power Distribution Units MandatoryType a UnitsType a Power Dual AC Power OptionalDistribution Units QuickSpecs Internal System Expansion Optional AlphaServer GS1280 Model 8 Internal System Expansion OptionsQuickSpecs QuickSpecs QuickSpecs ES/GS Common Options Contents Calculated Maximum Throughput Calculated Maximum Throughput Bit data pathAGP Overall System Capacities for I/O Adapters and ControllersPCI-X/PCI slots in Standard I/O Drawers Per systemMaximum High Performance I/O Drawers Four MHz PCI-X/PCI slots in High Performance DrawersPCI Adapters Installed Max Bus Speed4X AGP Standard I/O Drawer used in ES47, ES80, and GS1280 SystemsPort Bus # Slot # Signal Voltage Adapters Installed Max Bus SpeedTo EV7 3X-KZPEA-DB 3X-KZPCA-AA 3X-KZPDC-BE/DF 3X-KZPEC-BF/DG U320 LVD ScsiRail Spacing Vertical Rack CapacityHole Pattern Max Payload specdRackmount Kits Ethernet Network Interface Cards Description3X-DEGXA-TR 3X-DEGXA-SRAsynchronous Communications Network Interface Cards Memory Channel Adapter Memory Channel Optional Configuration GuidelinesCCMAB-BA CCMFB-BAMemory Channel Cables for Scsi and Backplane RAID Controllers Backplane RAID Scsi ControllersFibre Channel Controllers Cipca AdapterModel MSA30, Single StorageWorks Enclosures for Disks and Tapes OptionalBus Model MSA30, Dual Bus Model MSA30 Multi1000 HP StorageWorks Enterprise Virtual Array Disks OptionalModel EVA4000 EVA6000 EVA8000 EVA8000HP StorageWorks Disk Array xp10000 DrivesSdlt External HP StorageWorks Sdlt Tape Drive FamilyHP StorageWorks DLT VS Tape Drive Family DLT VS ExternalUltrium LTO External HP StorageWorks Ultrium LTO Tape Drive FamilyAutoloader Ultrium LTO HP StorageWorks 1/8 Tape Autoloader FamilyAutoloader Rack Mount Kit HP StorageWorks MSL2024 Tape LibraryTransfer native Maximum DataHP StorageWorks MSL6000 Tape Libraries MSL6026 MSL6030 MSL6052 MSL6060 Form Factor# of drives possible # of slots Configuration EML 103e EML 245e EML 442e EML 505eProduct height within Rack Maximum CapacityVLS Raw Capacity SwitchesMaximum Raw Capacity Usable CapacityOpenVMS Note Monitors Configuration Guidelines Keyboard, Video, Mouse KVM SwitchesRackmount Keyboard/Drawer Keyboard/Monitor Options CAT5e CablesCarbon/Silver Monitors Monitor Power CordsCarbon/Silver Flat Panel MonitorsGraphics Software Graphics AdaptersQA-6ADAA-GZ QA-6ADAA-H8OpenVMS Rules OpenVMS Galaxy Galaxy Soft PartitionService Part Numbers Hardware and Software Support Services OptionalProgram Features Principal Server HP Support Plus System Codes forHP Proactive Critical ServicesInstallation Program Features Additional ServicesInstallation and Startup HP O/SBasic Integration ServiceYT-VISIT-B1 YT-VISIT-R1Partitioning Service Clustering ServiceConfigurations Full CustomGS1280 Conversion AlphaServer GS1280, Upgrades for Single SystemsKit GS1280 Conversion Kit3X-BNPSB-03 3X-BNPSB-04 3X-BA65C-AA 3X-BA65D-AAPower Distribution Unit 3X-H7606-AA North America Japan Europe Power RequirementsPower Distribution Unit 3X-H7606-BA PDU required for all GS1280 ModelsPower Distribution Unit Power Required, KvaGS1280 Models 3X-H7606 Power Distribution Unit Models 32 and 64 H7606-Bx Physical CharacteristicsEnvironmental Operating Non-Operating Service Clearances-All Operating ModelsAcoustics Declared values per ISO 9296 and ISO