The analyzer can be configured dynamically, as needed, and this is the recommended method. The analyzer is configured dynamically by the following steps:

For 8-Channel EISA or NIO multiplexers connect an analyzer cable.

Start the ACC subsystem with the daemon pcapture running (this can be added to the zmasterd_list configuration file).

Use pdisplay to configure (use the runc command), start and stop the analyzer.

Use pdisplay to view the captured X.25 or ISDN traffic.

The analyzer can also be configured manually by adding the appropriate entries to the network configuration file (see “Network Configuration” on page 43 for more details). This file contains the initial configuration for the ACC Multiplexer subsystem. The configuration steps in this case would be:

Connect an analyzer cable for 8-Channel EISA or NIO multiplexers.

Configure the required analyzer ports as in Appendix A, “Network Configuration,” on page 43.

Start the ACC subsystem with the daemon pcapture running (this can be added to the zmasterd_list configuration file).

Use pdisplay to start and stop the analyzer.

Use pdisplay to view the captured X.25 or ISDN traffic.

Dynamic Set-Up of Analyzer Configuration

The analyzer can be conveniently configured and set up to run on specified ports/sub-channels using the runc command. The runc command configures the required ZCOM table entries (including ZLU numbers) for the specified port/subchannel before starting the capture and optional displaying of data.

Chapter 2

23

Image 23
Contents Edition ACC X.25 Data Analyzer User’s GuidePage Legal Notices Page Publishing History Page Manual Organization PrefaceSoftware Manuals Related DocumentationHardware Manuals Contents Typical X.25 and Data Analyzer Sessions Overview Data Analyzer Overview Overview of ACC based Data Analyzer Data Analyzer Overview Data Analyzer Features Data Analyzer Requirements Installing the Data Analyzer Software Removal Installing the Analyzer SoftwareSoftware Installation Verifying Installation Following four events will be displayed Display exit Exit Program Dynamic Set-Up of Analyzer Configuration Configuring the AnalyzerFirst 8-Channel multiplexer card in the ACC subsystem by Data Analyzer Commands Detailed Command Descriptions Description DisplayFormat Both X.25 and Isdn analyzer sessions ExampleLCI Exit Examples HelpOptions ASCII8 Protocol Run Examples Runc ZLU.# ShowAzlu Shutdown Stop Stopd Network Configuration Mux Firmware Download File Setting Up the Network Configuration FileZLU Definitions Port DefinitionsRunning Ttgen and Starting the ACC Mux Starting ACC Subsystem and Analyzer Running Pdisplay ASCII8 10 X25CNT,0,X25CNTLDSIZE Sample Network Configuration File43EAH Sample Network Configuration File Appendix a Typical X.25 and Data Analyzer Introduction General Procedures