HP UX 11i v2 I/O Cards manual Verifying Installation

Page 20

Installing the Data Analyzer

Installing the Analyzer Software

The “Install (analysis)” window allows you to track summary progress of the installation process. Use the “Logfile” feature to display a detailed status, which is logged to /var/adm/sw/swagent.log.

Verifying Installation

Check the end of the swinstall log file /var/adm/sw/swagent.log to ensure that there were no errors during the installation. If errors occurred, correct the problem and repeat the swremove and swinstall steps.

The Data Analyzer software contains a sample capture file. This file is installed into the directory /var/opt/acc/log and is called sample.eve. This file can be viewed using the pdisplay program. To try this, run pdisplay from the shell prompt.

If neither the ZCOM subsystem nor the pcapture program are currently up and running, the following message will be displayed:

$ pdisplay

Bad zinit call, error:ZCOM system is not started up Bad zopen call, error:Must call ZINIT first

Bad zopen call, error:Must call ZINIT first Bad zname call, error:Must call ZINIT first

***** Warning *****

Cannot find primary ZLU of pcapture - pcapture probably not running Some functions of this program will not be available

***** Warning *****

Cannot get storage offset for label ANLYZR,Error:Must call ZINIT first Display>

If the ZCOM subsystem is up and running but the pcapture daemon is not running, the following message will be displayed:

$ pdisplay

***** Warning *****

Cannot find primary ZLU of pcapture - pcapture probably not running Some functions of this program will not be available

***** Warning *****

Display>

20

Chapter 2

Image 20
Contents ACC X.25 Data Analyzer User’s Guide EditionPage Legal Notices Page Publishing History Page Preface Manual OrganizationSoftware Manuals Related DocumentationHardware Manuals Contents Typical X.25 and Data Analyzer Sessions Overview Data Analyzer Overview Overview of ACC based Data Analyzer Data Analyzer Overview Data Analyzer Features Data Analyzer Requirements Installing the Data Analyzer Installing the Analyzer Software Software RemovalSoftware Installation Verifying Installation Following four events will be displayed Display exit Exit Program Configuring the Analyzer Dynamic Set-Up of Analyzer ConfigurationFirst 8-Channel multiplexer card in the ACC subsystem by Data Analyzer Commands Detailed Command Descriptions Description DisplayFormat Example Both X.25 and Isdn analyzer sessionsLCI Exit Help ExamplesOptions ASCII8 Protocol Run Examples Runc Show ZLU.#Azlu Shutdown Stop Stopd Network Configuration Setting Up the Network Configuration File Mux Firmware Download FilePort Definitions ZLU DefinitionsRunning Ttgen and Starting the ACC Mux Starting ACC Subsystem and Analyzer Running Pdisplay ASCII8 Sample Network Configuration File 10 X25CNT,0,X25CNTLDSIZE43EAH Sample Network Configuration File Appendix a Typical X.25 and Data Analyzer General Procedures Introduction