HP UX 11i v2 I/O Cards manual ASCII8

Page 33

 

Data Analyzer Commands

 

options

z/Z

Turn off/ON Level 4 raw display (s/S option gives raw

 

mode).

To change the option setting use the set parameter followed by one or more of the letters in the table above; for example, the command below turns off the event and timestamp display, enables the Level 4 raw data display, and turns on the Modem control lead change display.

Display> options set eZL

To show the current option setting, use just the options command by itself or use the show parameter. Note that the options display includes a summary of the letters required to modify the setting beside each of the state indications. For example, in the line “Level 2 header decode: Yes u/U,” the letters u/U are used to turn OFF or ON the Level 2 header decoding.

Display> options show

Current option settings

Level 2 Decode header:

Yes u/U

Display raw data:

No

v/V

Level 3 Decode header:

Yes w/W

Decode facilities:

Yes x/X

Display raw data

No

y/Y

Display Event# & time (e/E) No

Display Lead changes (l/L)

Yes

Raw data display (see below)

ASCII8

Raw data single or full (s/S)

Single

Reverse Sense DTE/DCE (r/R) DCE

Example

To set the display options back to their original state use the default parameter:

Display> options default

Default display options set

Chapter 3

33

Image 33
Contents Edition ACC X.25 Data Analyzer User’s GuidePage Legal Notices Page Publishing History Page Manual Organization PrefaceRelated Documentation Hardware ManualsSoftware Manuals Contents Typical X.25 and Data Analyzer Sessions Overview Data Analyzer Overview Overview of ACC based Data Analyzer Data Analyzer Overview Data Analyzer Features Data Analyzer Requirements Installing the Data Analyzer Software Removal Installing the Analyzer SoftwareSoftware Installation Verifying Installation Following four events will be displayed Display exit Exit Program Dynamic Set-Up of Analyzer Configuration Configuring the AnalyzerFirst 8-Channel multiplexer card in the ACC subsystem by Data Analyzer Commands Detailed Command Descriptions Display FormatDescription Both X.25 and Isdn analyzer sessions ExampleLCI Exit Examples HelpOptions ASCII8 Protocol Run Examples Runc ZLU.# ShowAzlu Shutdown Stop Stopd Network Configuration Mux Firmware Download File Setting Up the Network Configuration FileZLU Definitions Port DefinitionsRunning Ttgen and Starting the ACC Mux Starting ACC Subsystem and Analyzer Running Pdisplay ASCII8 10 X25CNT,0,X25CNTLDSIZE Sample Network Configuration File43EAH Sample Network Configuration File Appendix a Typical X.25 and Data Analyzer Introduction General Procedures