Installing the Data Analyzer
Installing the Analyzer Software
Installing the Analyzer Software
The data analyzer software is provided with the ACC Base Product, which comes in
Installation requires the following general steps:
1. Remove any previous version of the data analyzer software with swremove.
2. Use swinstall to install the ACC base product (or just the data analyzer software if ACC base software is already installed).
3. Check /var/adm/sw/swagent.log for any errors during install.
4. Configure the analyzer.
|
| Software Removal |
|
| If a previous version of the ACC X.25 Protocol Analyzer product is |
|
| already on the target system, remove it before the new software is |
|
| installed. |
|
|
|
CAUTION |
| It is very important to follow the instructions, provided with the ACC |
|
| software that is currently installed in the system, to shut down and |
|
| remove that software. This procedure may change between major |
|
| releases of the ACC product. |
|
|
|
Step | 1. | Log in to the system as superuser. |
Step | 2. | Terminate the ACC Mux Subsystem by typing: |
|
| % zmasterd kill |
Step | 3. | Run swremove to remove the ACC X.25 Protocol Analyzer product. |
|
| % swremove |
18 | Chapter 2 |