Raypak 120, 85 manual START-UP Procedure, Are several steps involved in starting up the boiler

Page 39

Fig. 41

39

 

 

FOR YOUR SAFETY READ BEFORE OPERATING

 

 

 

 

 

POUR VOTRE SÉCURITÉ LISEZ AVANT DE METTRE EN MARCHE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WARNING: If you do not follow these instructions exactly, a fire or explosion

 

 

 

 

 

 

 

 

 

 

 

AVERTISSEMENT: Quiconque ne respecte pas à la lettre les instructions dans la

 

 

may result causing property damage, personal injury, or loss of life.

 

 

 

présente notice risque de déclencher un incendie ou une explosion entraînant des

 

 

 

 

 

 

 

 

 

dommages, des blessures ou la mort.

 

 

 

 

A. This appliance does not have a pilot. It

- If you cannot reach your gas supplier,

 

 

 

 

 

 

A.Cet appareil ne comporte pas de veilleuse.

instructions du fornisseur

 

 

is equipped with an ignition device

call the fire department.

 

 

Il est muni d'un dispositif d'allumage qui

- Si vous ne pouvez rejoindre le

 

 

which automatically lights the burner. Do

C. Use only your hand to turn the gas control

 

 

allume automatiquement le brûleur. Ne

fournisseur, appelez le service des

 

 

not try to light the burner by hand.

knob. Never use tools. If the handle will

 

 

tentez pas d'allumer le brûleur

incendies.

 

 

B. BEFORE OPERATING smell all around

not turn by hand, don't try to repair it,

 

 

manuellement.

C. Ne poussez ou tournez la manette

 

 

the appliance area for gas. Be sure to

call a qualified service technician. Force

 

 

B. AVANT DE FAIRE FONCTIONNER, reniflez

d'admission du gaz qu'à la main; ne

 

 

smell next to the floor because some

or attempted repair may result in a fire

 

 

tout autour de l'appareil pour déceler une

jamais utiliser d'outil. Si la manette reste

 

 

gas is heavier than air and will settle on

or explosion.

 

 

odeur de gaz. Reniflez près du plancher,

coincée, ne pas tenter de la réparer;

 

 

 

 

car certains gaz sont plus lourds que l'air

appelez un technicien qualifié. Le fait de

 

 

the floor.

D. Do not use this appliance if any part has

 

 

 

 

 

 

et peuvent s'accumuler au niveau du sol.

forcer la manette ou de la réparer peut

 

 

WHAT TO DO IF YOU SMELL GAS

been under water. Immediately call a

 

 

 

 

 

 

QUE FAIRE SI VOUS SENTEZ UNE ODEUR

déclencher une explosion ou un incendie.

 

 

- Do not try to light any appliance.

qualified service technician to inspect the

 

 

 

 

 

 

DE GAZ:

D. N'utilisez pas cet appareil s'il a été plongé

 

 

- Do not touch any electric switch; do not

appliance and to replace any part of the

 

 

 

 

 

 

- Ne pas tenter d'allumer l'appareil

dans l'eau, même partiellement. Faites

 

 

use any phone in your building.

control system and any gas control which

 

 

 

 

 

 

- Ne touchez à aucun interrupteur; ne pas

inspecter l'appareil par un technicien

 

 

- Immediately call your gas supplier from

has been under water.

 

 

vous servir des téléphones se trouvant

qualifié et remplacez toute partie du

 

 

a neighbor's phone.

 

 

 

 

 

dans le bâtiment

système de contrôle et toute commande

 

 

Follow the gas supplier's instructions.

 

 

 

 

 

- Appelez immédiatement votre fournisseur

qui ont été plongés dans l'eau.

 

 

 

 

 

 

 

 

 

de gaz depuis un voisin. Suivez les

 

 

 

 

OPERATING INSTRUCTIONS

 

INSTRUCTIONS D'ALLUMAGE

 

1.

STOP! Read the safety information above

If you then smell gas, STOP! Follow "B"

1.

ARRÊTEZ! Lisez les instructions de

 

l'étape "B" des instructions de sécurité

 

on this label.

in the safety information above this label.

 

sécurité sur la portion supérieure de cette

 

sur la portion supérieure de cette

2.

Set the thermostat to lowest setting.

If you don't smell gas, go to next step.

 

étiquette

 

étiquette. S'il n'y a pas d'odeur de gaz,

3.

Turn off all electric power to the appliance.

8. Turn gas shutoff valve counterclockwise

2.

Réglez le thermostat à la température la

 

passez à l'étape suivante.

 

4.

This appliance is equipped with an

to open valve. Handle will be parallel to

3.

plus basse

8.

Tourner le bouton de commande de

 

ignition device which automatically lights

pipe.

Coupez l'alimentation électrique de

 

gaz dans le sense antihoraire à la

 

the burner. Do not try to light the burner

9. Install top cover.

 

l'appareil

 

position "marche" (ON)

 

 

4.

Cet appareil ne comporte pas de

9.

Remontez le couvercle

du haut

 

by hand.

10. Turn on all electric power to appliance.

 

 

veilleuse. Il est muni d'un dispositif

10. Mettez l'appareil sous

tension

5.

Remove top cover.

11.Set thermostat to desired setting.

 

 

d'allumage qui allume automatiquement

11. Réglez le thermostat à la température

6.

Turn gas shutoff valve clockwise to close

12.If the appliance will not operate, follow

 

le bruleur. Ne tentez pas d'allumer le

 

désirée

 

 

valve. Handle will be perpendicular to

the instructions "To Turn Off Gas To

5.

bruleur manuallement.

12. Si l'appareil ne se met pas en marche,

7.

pipe. Do not force.

Appliance" and call your service

Retirez le couvercle du haut

 

suivez les instructions intitulées

Wait five (5) minutes to clear out any gas.

technician or gas supplier.

6.

Tournez le bouton de la vanne de gaz

 

"Comment couper l'admission de gaz

 

 

 

 

dans le sens horaire à la position "arret"

 

de l'appareil" et appelez un technicien

 

 

 

 

(OFF)

 

qualifié ou le fournisseur

de gaz.

 

Gas Valve OPEN

Gas Valve CLOSED

7.

Attendre cinq (5) minutes pour laisser

 

 

 

 

 

 

 

échapper tout le gaz. Si vous sentez une

 

 

 

 

 

 

 

odeur de gaz, ARRÊTEZ! Passez à

 

 

 

 

 

 

 

vanne gaz en marche

vanne gaz en arret

 

 

to CLOSE

to OPEN

 

 

 

 

 

 

 

 

 

pour

 

pour

 

 

 

 

 

fermer

 

ouvrir

 

 

TO TURN OFF GAS TO APPLIANCE

 

COMMENT COUPER L'ADMISSION DE GAZ L'APPAREIL

 

1. Set the thermostat to lowest setting.

4. Turn gas shut off valve clockwise to close

1. Réglez le thermostat à la température la

4. Tournez le bouton de commande de gaz

2. Turn off all electric power to the appliance

valve. Handle will be perpendicular to pipe.

 

plus basse

 

dans le sens horaire à la position "arret"

 

if service is to be performed.

Do not force.

2. Coupez l'alimentation électrique de

5. Remontez le couvercle

du haut.

3. Remove top cover.

5. Install top cover.

 

l'appareil s'il faut procéder à l'entretien

 

 

 

 

 

 

3. Retirez le couvercle

 

Cod. 20003235

There

8 -

are several steps involved in starting up the boiler.

START-UP PROCEDURE

Image 39
Contents Page About the XPak About these instructionsContents PAY Attention to These Terms Following instructions must be observedYou must also observe Tools, materials and additional equipment What to do if you smell gasObserve these instructions as general warnings Observe these instructions for space heating waterWater Time to Produce Serious General SafetyBefore Installation M E / T E M P E R a T U R E Relationships in ScaldsOperating Limits of the boiler Regulations and GuidelinesGeneral layout Fig IntroductionAB C DE Technical Data Max flues length de-rate less 2% Recommended Minimum Service ClearancesBoiler Dimensions And Weight XPakPrinciple Components Manual Handling Statement Mode of Operation AT RestXpak Internal Hydraulic Circuit FIG Mode of Operation Safety DevicesPiping Connections FIG Dimensions and Connections Fig Transporting the Boiler Boiler BOX Content Table Pos Parts Quantity PackagingPackaging and Transportation Scope of DeliveryInstallation Prepare Xpak LocationPrepare Xpak Xpak Piping Pump Duty Procedure SummaryBoiler with DHW Tank Waterside Flow Primary CircuitKey for installation sample diagrams Xpak Installation DiagramsPage Page Equivalent length for pipe fittings in feet Length Gas Volume Capacity Pipe feet Ft 3/hMaking the GAS Connection Gas Pipe Capacity for different pipe sizesBoiler Template Fig All Air from Outdoor sealed combustion All Air from Inside the Building room airVent Systems Flue GAS SystemBoiler Supply Minimum Clearances from VENT/AIR Inlet Termination Installations1 Canadian Installations2Vertical Coaxial Sealed Combustion Operation TWO Pipes Single Wall Room AIR Dependent Operation Stainless steel Field supplied013102 Description Diagram Drawing TWO Pipes Single Wall = total intake length = Electrical Connections Connecting the Condensate Water DrainAppliance Terminal Block External WiringExternal Wiring Limitations Connecting ThermostatTerminal Strip Details HighLow WAY Valve Wiring Connection Remote Control ConnectionOutdoor Sensor Connection Wiring Functional Diagram Are several steps involved in starting up the boiler START-UP ProcedureHeating System Freeze Protection When UsedCommissioning CHECK/CONTROL Water ChemistryInitial Flushing of the System Testing for GAS LeaksInitial Lighting and Ignition Safety Shutoff Device Test Check Thermostat CircuitsWarranty Final ChecksInstructing the User START-UP and Operation Switching on the ApplianceReset Function Switching OFFIndicator Leds and Faults Green indicator LED FigRed indicator LED Fig For alarm AL91 For AL41 faultsCHECKS, Adjustments and Fault Finding Installation Faults CHECKING/ADJUSTING the Boiler FAN SpeedsGAS Valve Minimum Pressure Setting External FaultsElectrical Checks Fault FindingReversed Polarity or Supply Fault Boiler ConfigurationType of Heat Request Standard Setting the Outdoor Reset Curve with Outdoor SensorProgrammable Timer DAY+NIGHT Selecting the offset heating curve Fig212 194 176 158 140 122 104 Code Cause Alarm Type Action Fault CodesGeneral Replacement of ComponentsComponent Removal Procedure Servicing InstructionsPrinted Circuit Board Fig Water Pressure Switch FigFlow Sensor Primary Thermistor Fig Return Sensor Return Thermistor FigMain Heat Exchanger Fig Blocked Flue Pressure SWITCH/IGNITION Transformer FigFlue FAN & Mixer Fig Burner FigFlue Collector and Flue Thermostat Removal Fig Condensate Trap Removal FigGAS Supply GAS Supply InstallationLPG Instructions Propane GASTechnical Data LPG Sequence of the Ignition System Exploded Diagrams 56a Xpak Drawing Call OUT Description Important Instructions for the Commonwealth of Massachusetts Applicable Warranty Periods Limited WarrantyHOW to Make Warranty Claim START-UP Checklist for FAN-ASSISTED Raypak Products Your XPak serial number For future reference

120, 85 specifications

The Raypak 120,85 is a prominent model in the realm of pool and spa heating solutions, designed to deliver unmatched efficiency and performance. Renowned for its robust features and innovative technologies, the Raypak 120,85 stands out as a reliable choice for homeowners seeking to maintain the perfect water temperature in their pools and spas.

One of the primary characteristics of the Raypak 120,85 is its impressive heating capacity. With a total output of 120,000 BTUs, this heater quickly and efficiently warms up water, ensuring that users can enjoy comfortable swimming conditions regardless of the outdoor temperature. The 85 indicates its ability to deliver consistent performance even in cooler climates, making it an adaptable option for various geographical locations.

The Raypak 120,85 is equipped with a state-of-the-art, copper fin tube heat exchanger, which provides superior heat transfer efficiency. This technology enhances the heater's ability to warm water rapidly while maintaining energy efficiency. Additionally, the copper material is known for its durability and resistance to corrosion, ensuring a long lifespan for the heat exchanger.

Another key feature of the Raypak 120,85 is its electronic ignition system. This innovation eliminates the need for a standing pilot light, which not only saves energy but also enhances safety by reducing the risk of gas leaks associated with traditional ignition systems. The electronic ignition provides precise control, ensuring a reliable start each time.

The Raypak 120,85 also boasts a digital display control panel, allowing users to easily monitor and adjust the water temperature settings. This intuitive interface provides accurate readings and simplifies the operation, making it accessible for all users, regardless of their technical expertise.

Furthermore, this heater is designed with a compact footprint, making it suitable for a variety of installation spaces, whether it’s in a pool equipment area or near a spa. Its robust build quality and weather-resistant design ensure that it can withstand the elements, making it a durable and long-lasting investment.

In summary, the Raypak 120,85 combines advanced heating technology, robust construction, and user-friendly features. With its high BTU output, efficient heat exchanger, electronic ignition, and digital controls, it represents a top-tier option for anyone seeking reliable and effective heating solutions for pools and spas. Whether for leisure or relaxation, the Raypak 120,85 promises to deliver an optimal swimming experience, season after season.