FOR INTERMITTENT IGNITION (IID) WITH HONEY- WELL OR ROBERTSHAW GAS VALVE (For All Mod- els)
1.STOP! Read the safety information above.
2.Set the thermostat to the lowest setting.
3.Turn off all electric power to the appliance.
4.This boiler is equipped with an ignition device which automatically lights the pilot. Do not try to light the pilot by hand.
GAS CONTROL
KNOB SHOWN
IN "ON"
POSITION
GAS INLET
Fig. #8201.0
HONEYWELL
(Models 30 - 90)
5.For Honeywell Valve: Turn gas control knob
clockwise to "Off".
For Robertshaw Valve: Push in and move gas control lever to "Off" position.
6.Wait 5 minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow "B" in the safety information above on this label. If you don't smell gas, go to the next step.
7.For Honeywell Valve: turn gas control counter-
clockwise to "On".
For Robertshaw Valve: Move gas control lever to "On" position.
GAS CONTROL
KNOB SHOWN
IN "OFF"
POSITION
GAS INLET
Fig. #8199.0
ROBERTSHAW
(All Models)
8.Turn on all electric power to the boiler.
9.Set thermostat to desired setting.
10.If the boiler will not operate, follow the instruction "To Turn Off Gas To Boiler" and call your service technician or gas supplier.
TO TURN OFF GAS TO BOILER
1.Set the thermostat at the lowest setting.
2.Turn off all the electric power to the boiler if service is to be performed.
3.For Honeywell Valve:
Turn gas control knob clockwise |
|
| to |
| |||
"Off". Make sure knob rest against |
|
|
|
stop. |
| ||
For Robertshaw Valve: |
| ||
Push in and move gas control lever to "Off" |
| ||
position. |
|
HONEYWELL PILOT
SYSTEM SHUT DOWN PROCEDURE
To prevent the potential freezing damage to the heating system, it is recommended that the following system shut down procedure be performed.
1.Set the room thermostat to "OFF" or the lowest setting.
2.Turn off all electric switches to the boiler.
3.Turn off all gas valves supplying gas to the boiler. Refer to operating instruction label on the boiler.
4.Shut off the water supply to the boiler piping system loop.
5.Open drain valve on the boiler to remove water from the boiler and the piping circuits.
Note: It may be necessary to open the purge valves and/ or manual air vents to facilitate complete drainage of water from the heating system.
26