GE 5500 manual Ducted Application AZ2500/3500 Series, Duct Adapter Extension has 1/2 Insulation

Page 38

38 DUCTED APPLICATION (AZ2500/3500 SERIES)

44"

RAK6052

ADAPTER

TRANSITION

NOTES:

1.RAK6052 kit includes duct adapter, transition and mounting hardware.

2.RAK601 duct extension may be installed at either end of the RAK6052 duct adapter. Maximum duct extension length is 15'. Duct extension must be field fabricated for installations where length of duct exceeds length of RAK601 (44"). Field fabricated duct extension must be insulated to prevent condensation from forming on exterior. Duct extension may not contain bends or turns.

3.Ducted units may need to be permanently connected. Check local code for specific electrical installation requirements.

4.Duct extension kit RAK601 contains 44" duct extension, discharge grille mounting collar, and discharge grille. Duct extension must be cut to required length. Two ducted installations may be made from one kit if the combined ducted length is less than 44". RAK602 kit contains mounting collar, discharge grille and mounting hardware necessary for second installation.

5.Filler strip (field supplied) actual width depends upon wall case projection into room. A flush installation to finished wall (i.e., no filler strip) can be made.

6.Unit must be installed to provide at least a 2" clearance between side of unit and wall.

7.Provisions for return air must be made in order to allow air circulation from secondary room. Doors in both secondary and primary rooms may be undercut or a return grille may be installed through common wall.

8.For replacement of previous design units, see pages 37 and 58.

RAK601

44" LENGTH

8" high

- 3/8"

7

wide

 

RECOMMENDED MINIMUM CLEARANCE

2" TO SIDE WALL

DUCT ADAPTER EXTENSION HAS 1/2" INSULATION

Image 38
Contents Architects and Engineers Design Data Manual 3500 Series Control Panel Series Heat Pump with Backup Resistance HeatQuick Reference Series Cooling with Electric HeatSeries Control Panel EER COPCooling With Resistance Heat Newest Innovation from GETable of Contents Important NoticeIntroduction Deluxe Series shown Optional Accessories of the Zoneline SystemComponents of the Zoneline System Zoneline Features Model Series UPCFeatures and Benefits Compressor Restart Delay Fan Only Setting HIGH/LOWFan Cycle Switch SmartFan Electronic Temperature LimitingConcealed Manual Vent Control Easy Clean Air Discharge AreaUp-Front Air Filters Corrosion Protection OptionalHeating Temperature Limits Auxiliary Control SwitchesCooling Temperature Limits 3500 SeriesSeries DiagnosCentral Desk Control Remote Thermostat Control Resistance Heat ModelsRAK806 Universal Control Cover Label Heat Pump ModelsFeature Series See RAK806 Universal Control cover Label onR1, R2, and R3 For Use With Mechanical 4-Wire Systems OnlyRemote Control Low Voltage Wiring Special order, 100 piece minimum orderHeat pump condensate Heat Pumps and Energy SavingsBalance Point Zoneline 5500 Series Heat Source Logic Heat pump defrost Zoneline 5500 SeriesHeat Pump Operation Zoneline 5500 Series Recommendation Application CommentsAir Distribution High Wall Mount For unitsDimensions RAK204 Wall CaseSub-Base General Wall Case Installation DataWindow, Curtain and Panel Wall Construction Brick, Frame, Stucco and Shingle Construction Installation of Wall Case in Wall OpeningMasonry Wall Construction Preparation of the Wall Case for All Types of ConstructionFraming for Wall Case Fastening Wall CaseWall Case Wall Section Detailed Side ViewRoom Cabinet Room Wall Case CabinetWall Case Receptacle RoomCabinet Wall Case By OthersWall Case Installation Cord SET Connected CaulkCorner and lap joints be additionally sealed Page Shown with Access Covers Removed Alternates Small Recommend 2 to Adjustable CaulkHoles by Installer TOP ViewType B Screw Green Ground RAK204 Series SUB-BASE Installation and Electrical DataChaseway Option Metal Case Screw Clip Type D Type a To Secure Side ChannelsCondensate Disposal Systems Cooling CondensateRear Grille Typical InstallationWall Case with RAD10 Drain KIT Wall Case Room CabinetUSE Type a Screws for Both RAB71 and RAB77 NUT Molded Case RAB77 only DetailGasket Cabinet Bottom Tube Cover Plate Replacements of Existing Ducted Units Ducted InstallationsNew Ducted Installations Ducted Application ConsiderationsDucted Application AZ2500/3500 Series Duct Adapter Extension has 1/2 InsulationSub-Base Installation Ducted Detailed Side Views AZ2500/3500 SeriesExterior Grilles Sample Calculations230/208 Volt Unit Installation Permanent Connected Units Power Connection For Deluxe Series 2500230/208 Volt Unit Installation Line Cord Connected Units 265 or 277 Volt Unit Installation Permanent Connected UnitsPower Connection Kits For Premium Series 230/208 Volt InstallationsReplacement of Existing Chassis Maximum Connected Load For Deluxe Series 2500 Cooling Performance Data Heat Pump Performance DataLatent System Capacity Formula for Calculating Operating Costs Using Above Data Normal Yearly Operating DataDrive Board Unit Typical 2500 Series Wiring DiagramTypical 2500 Series Schematic Diagram Board Unit Typical 3500 Series Wiring DiagramTypical 3500 Series Schematic Diagram Typical 5500 Series Wiring Diagram Typical 5500 Series Schematic DiagramSuggested Bid Form Specifications Page Alternate specification for molded wall case Deluxe Line Dry Air 25 & 3500 Series Receptacles/Sub-Bases Complete Accessory List Kit Number Description For Additional Information Refer toGeneral Installation Suggestions Electrical Wiring InstallationNew Installations Replacement InstallationsAlphabetical Index CategoryZoneline

5500 specifications

The GE 5500 is a sophisticated gas turbine that represents a benchmark in the realm of power generation technology. Known for its impressive performance and efficiency, the GE 5500 has garnered attention in various industries, particularly in energy production. Designed for combined-cycle applications, this turbine effectively leverages both gas and steam cycles to optimize electricity generation.

One of the standout features of the GE 5500 is its advanced aerodynamics, which enhance the efficiency of the combustion process. The turbine employs state-of-the-art combustion technology that allows for high operational flexibility and minimizes emissions, meeting stringent environmental standards. This is particularly important in today’s energy landscape, where sustainability is a crucial focus.

The GE 5500 is equipped with a robust control system that utilizes digital twin technology. This innovative approach allows operators to simulate and analyze the performance of the turbine virtually, leading to improved operational efficiency and reduced downtime. Additionally, this turbine features an integrated health monitoring system that provides real-time data on performance metrics, allowing for predictive maintenance and enhancing overall reliability.

The materials used in the construction of the GE 5500 are engineered to withstand high temperatures and stress levels, ensuring longevity and durability. This includes high-performance alloys that maintain structural integrity even under extreme operating conditions.

Installation and maintenance of the GE 5500 are streamlined through its modular design, which simplifies access to components and reduces service time. This efficiency translates into lower operational costs, making the GE 5500 an economically favorable choice for utilities and independent power producers.

Furthermore, the GE 5500 can be integrated into a variety of power plant configurations, whether for peaking power or baseload operations, which adds to its versatility. Its ability to quickly ramp up production makes it particularly valuable in an energy market characterized by fluctuating demand.

Overall, the GE 5500 gas turbine is a remarkable engineering feat that combines cutting-edge technology with practical design. Its efficiency, reliability, and adaptability position it as a leading choice for power generation needs, meeting the requirements of modern energy systems while contributing to a more sustainable future.