GE 5500 manual Corner and lap joints be additionally sealed

Page 30
D
AS REQ'D.

30

METAL CASE EXTENSION FOR WALLS DEEPER THAN 13-1/8" (11-1/8" WITH SUB-BASE)

FIELD FABRICATED – GE RECOMMENDS THE USE OF ONE OF THE DEEPER RAB71 WALL CASES OFFERED AS SPECIAL ORDER ITEMS. SEE PAGE 29.

Zoneline units can be installed in walls of greater depth than the wall case. Where the case recession is less than 3” and where it is possible to waterproof the exposed sides and top of the opening, the suggested procedure is to apply a flashing to the bottom of the wall case as shown on page 29. Where waterproofing is questionable or not possible, or for installations in walls of greater

2. The wall case and extension should be connected prior to installation in the wall opening. A quality grade sealant should be applied to all four (4) butting flanges. Use bolts and nuts or oversized self tapping screws (driven from the wall case to the extension) to attach the two assemblies. Clean all drain holes of excess sealant. The assembly must be free

5.Suggested materials for case extension and flashing should be non-ferrous metals. Minimal acceptable material: Galvanized G-90 painted.

depth, the following is a suggested application procedure. It involves the field fabrication of a case extension. Since the wall case is a water bearing container, the extension likewise must also be water bearing and the connection between the two must be watertight. The case extension must contain splitters to prevent recirculation of the outdoor air circuit.

1. The case extension is field fabricated. The

extension depth “D” should allow for a minimum

outdoor projection of 1/4”. This allows for room

cabinet clearance to the finished wall and ample

surfaces to apply sealant or caulking for a tight

weather seal between the completed wall

case/extension assembly and the wall opening. It

is recommended that the extension be painted

draining.

3. Install flashing, using a quality grade sealant between the flashing and wall as shown in section A-A below.

4. Install the wall case/extension assembly following procedures described for a standard installation. See diagrams below. The assembly should be sealed or caulked to the wall around all four sides both outdoors and indoors.

NOTE: The wall case/extension assembly should be level.

6-1/4" ± 1/4"

SEALANT - ALL

FOUR (4) FLANGES

CAULK*

ROOM

CABINET

WALL -

ANY

CONSTRUCTION

RAB71/77

CASE

 

EXT.

1/4" MIN.

CAULK*

and corner and lap joints be additionally sealed

with a quality grade sealant.

SPLITTER BETWEEN

AIR INTAKE AND

DISCHARGE

CAULK*

CAULK*

SEE DETAIL

SECTION A-A

*Caulk around perimeter of wall case all four sides where it joins the building - Interior and Exterior.

SECTION A-A

BASEPAN/FLANGE DESIGN

SHOWING SEALANT LOCATIONS.

 

 

CUT DRAIN SLOTS

 

1-1/2"

IN BOTH FLANGES

 

(FOUR REQUIRED)

RAB71/77

(4 SIDES)

TO MATCH DRAIN

WALL CASE

EXTENSION

HOLES IN RAB71/77

 

(FIELD

 

 

SUPPLIED)

 

ALL 4 FLANGES

WALL CASE

EXTENSION

2" MIN.

FLASHING (FIELD SUPPLIED)

13-3/4" + D"

ALL 4

SIDES

FLANGES AND

DRAIN HOLE

LOCATIONS

SAME AS ON

WALL CASE

1" WIDE 45° DRIP LIP

FLASHING

ALL 4

SIDES

 

WALL

Image 30
Contents Architects and Engineers Design Data Manual 3500 Series Control Panel Series Heat Pump with Backup Resistance HeatQuick Reference Series Cooling with Electric HeatSeries Control Panel EER COPCooling With Resistance Heat Newest Innovation from GETable of Contents Important NoticeIntroduction Optional Accessories of the Zoneline System Components of the Zoneline SystemDeluxe Series shown Zoneline Features Model Series UPCFeatures and Benefits Compressor Restart Delay Fan Only Setting HIGH/LOWFan Cycle Switch SmartFan Electronic Temperature LimitingConcealed Manual Vent Control Easy Clean Air Discharge AreaUp-Front Air Filters Corrosion Protection OptionalHeating Temperature Limits Auxiliary Control SwitchesCooling Temperature Limits 3500 SeriesSeries DiagnosCentral Desk Control Remote Thermostat Control Resistance Heat ModelsRAK806 Universal Control Cover Label Heat Pump ModelsFeature Series See RAK806 Universal Control cover Label onR1, R2, and R3 For Use With Mechanical 4-Wire Systems OnlyRemote Control Low Voltage Wiring Special order, 100 piece minimum orderHeat Pumps and Energy Savings Balance PointHeat pump condensate Heat pump defrost Zoneline 5500 Series Heat Pump Operation Zoneline 5500 SeriesZoneline 5500 Series Heat Source Logic Recommendation Application CommentsAir Distribution High Wall Mount For unitsDimensions Wall Case Sub-BaseRAK204 Wall Case Installation Data Window, Curtain and Panel Wall ConstructionGeneral Brick, Frame, Stucco and Shingle Construction Installation of Wall Case in Wall OpeningMasonry Wall Construction Preparation of the Wall Case for All Types of ConstructionFraming for Wall Case Fastening Wall CaseWall Case Wall Section Detailed Side ViewRoom Cabinet Room Wall Case CabinetWall Case Receptacle RoomCabinet Wall Case By OthersWall Case Installation Cord SET Connected CaulkCorner and lap joints be additionally sealed Page Shown with Access Covers Removed Alternates Small Recommend 2 to Adjustable CaulkHoles by Installer TOP ViewType B Screw Green Ground RAK204 Series SUB-BASE Installation and Electrical DataChaseway Option Metal Case Screw Clip Type D Type a To Secure Side ChannelsCondensate Disposal Systems Cooling CondensateRear Grille Typical InstallationWall Case with RAD10 Drain KIT Wall Case Room CabinetNUT Molded Case RAB77 only Detail Gasket Cabinet Bottom Tube Cover PlateUSE Type a Screws for Both RAB71 and RAB77 Replacements of Existing Ducted Units Ducted InstallationsNew Ducted Installations Ducted Application ConsiderationsDucted Application AZ2500/3500 Series Duct Adapter Extension has 1/2 InsulationSub-Base Installation Ducted Detailed Side Views AZ2500/3500 SeriesExterior Grilles Sample Calculations230/208 Volt Unit Installation Permanent Connected Units Power Connection For Deluxe Series 2500230/208 Volt Unit Installation Line Cord Connected Units 265 or 277 Volt Unit Installation Permanent Connected UnitsPower Connection Kits For Premium Series 230/208 Volt InstallationsReplacement of Existing Chassis Maximum Connected Load For Deluxe Series 2500 Cooling Performance Data Heat Pump Performance DataLatent System Capacity Formula for Calculating Operating Costs Using Above Data Normal Yearly Operating DataTypical 2500 Series Wiring Diagram Typical 2500 Series Schematic DiagramDrive Board Unit Typical 3500 Series Wiring Diagram Typical 3500 Series Schematic DiagramBoard Unit Typical 5500 Series Wiring Diagram Typical 5500 Series Schematic DiagramSuggested Bid Form Specifications Page Alternate specification for molded wall case Deluxe Line Dry Air 25 & 3500 Series Receptacles/Sub-Bases Complete Accessory List Kit Number Description For Additional Information Refer toGeneral Installation Suggestions Electrical Wiring InstallationNew Installations Replacement InstallationsAlphabetical Index CategoryZoneline

5500 specifications

The GE 5500 is a sophisticated gas turbine that represents a benchmark in the realm of power generation technology. Known for its impressive performance and efficiency, the GE 5500 has garnered attention in various industries, particularly in energy production. Designed for combined-cycle applications, this turbine effectively leverages both gas and steam cycles to optimize electricity generation.

One of the standout features of the GE 5500 is its advanced aerodynamics, which enhance the efficiency of the combustion process. The turbine employs state-of-the-art combustion technology that allows for high operational flexibility and minimizes emissions, meeting stringent environmental standards. This is particularly important in today’s energy landscape, where sustainability is a crucial focus.

The GE 5500 is equipped with a robust control system that utilizes digital twin technology. This innovative approach allows operators to simulate and analyze the performance of the turbine virtually, leading to improved operational efficiency and reduced downtime. Additionally, this turbine features an integrated health monitoring system that provides real-time data on performance metrics, allowing for predictive maintenance and enhancing overall reliability.

The materials used in the construction of the GE 5500 are engineered to withstand high temperatures and stress levels, ensuring longevity and durability. This includes high-performance alloys that maintain structural integrity even under extreme operating conditions.

Installation and maintenance of the GE 5500 are streamlined through its modular design, which simplifies access to components and reduces service time. This efficiency translates into lower operational costs, making the GE 5500 an economically favorable choice for utilities and independent power producers.

Furthermore, the GE 5500 can be integrated into a variety of power plant configurations, whether for peaking power or baseload operations, which adds to its versatility. Its ability to quickly ramp up production makes it particularly valuable in an energy market characterized by fluctuating demand.

Overall, the GE 5500 gas turbine is a remarkable engineering feat that combines cutting-edge technology with practical design. Its efficiency, reliability, and adaptability position it as a leading choice for power generation needs, meeting the requirements of modern energy systems while contributing to a more sustainable future.