Rinnai RL94I, RL75I installation manual Tuyauterie recommandée pour installation de base, Légende

Page 56

Tuyauterie recommandée pour installation de base

Conduite de sortie d'eau chaude en 3/4 po

(19 mm)

3/4" Hot Water Supply Line

AppareilsFor Buildingdu bâtimentFixtures

ChauffeRinnai-eau

WaterRinnaiHeater

 

 

Liste d'équipement

 

 

 

Rinnai

 

Qté

 

 

Rinnai

 

 

 

 

Equipment List

QTY

 

 

Chauffe-eau Rinnai

1

 

 

Rinnai

 

 

 

 

Water Heaters

 

1

 

 

Kit RIK (optionnel)

1

 

 

(raccords 3/4

(19 mm)

1

 

 

RIK-KIT (Optional)

 

 

comprena(3/4" Fittintgs: Include:

 

 

 

22unions,Unions,2 2vannesBall Valves,à boisseau

 

 

sphérique,2 Drain Valves2 électrovannesand

de

 

 

drainage,1 Pressure1 soupapeRelief Valvede sûreté).

 

 

 

 

Connexion de

gaz en 3/4 po

 

 

3/4"

Gas Connection

 

 

(19 mm)

 

 

 

 

 

 

 

Alimentation en gaz

Gas Supply

Conduite d'alimentation en eau froide en 3/4 po (19 mm) 3/4" Cold Water Supply Line

Légende

Vanne à tournant sphérique

 

 

 

Régulateur de pression

 

 

 

3/4 po (19 mm)

 

 

 

Pressure Regulator

3/4" Ball Valve

 

 

 

Pompe de circulation

Raccord union 3/4 po (19 mm)

 

 

 

 

 

 

Circulating Pump

3/4" Union

 

 

 

Clapet anti-retour

 

 

 

 

Vanne de purge de

 

 

 

 

 

 

 

 

 

 

Check Valve

 

 

 

 

chaudièreBoiler Drain Valve

SoupapePressuredeReliefdéchargeValve

S ÉlectrovanneSolenoid Valve

Ceci n'est pas un schéma technique, son but n'est que de vous guider, et il ne tient This is not an engineered drawing, it is intended only as a guide and

pas lieu de dessin industriel professionnel pour un projet. Ce schéma n'a pas not as a replacement for professionally engineered project drawings.

l'ambition de décrire un système au complet. C'est la responsabilité du concepteur This drawing is not intended to describe a complete system, it is up

ou de l'ingénieur de déterminer les composants nécessaires la configuration pourtolethesystèmecontractor/engineerspécifique à installerto determine. Ce schémathen'impliquenecessaryaucunecomponentsconformité

avecforlesandexigencesconfigurationdes normesof thede constructionparticular systemlocales.beingC'est lainstalledresponsabilité. Thedu

concepteurdrawingoudoesl'ingénieurot implydecompliances'assurer quewithl'installationlocal buildingsera en conformitéde avec

toutesrequirementsles normes locales. It is thede coenstructiongineer/contractorapplicables.responsiblityConsultez les autoritésensure

compétentesthe installationdans ceisdomaineaccordanceavant l'installationlocalwith. building codes. Confer with local building officials before installation.

56

Manuel – Chauffe-eau d’intérieur série VB LS

Image 56
Contents REU-VB2528FFUD-US Table of Contents Specifications RL75i RL94i R98LSiConsumer Safety Information Safety DefinitionsSafety Behaviors and Practices Safety Features Description of OperationTemperature Controller MC-91-1US & MCC-91-1USFeatures Available on Temperature Controllers FeaturesOperating Instructions MC-91 MCC-91 MC-100 BC-100 MC-502 DescriptionModel Temperature Settings Available ºF How to Set the TemperatureTemperature Controller Settings Temperature Options Without a Temperature Controller Setting the Sound Volume Voice PromptRe-setting the Maximum Temperature RL75 and RL94 only MCC-91 Temperature ControllerOverview Using the Water Smart / Bath Fill FunctionSetting the Water Volume Setting Controller to Mute Setting the ClockFilling the Tub Models MC-91 and MCC-91Maintenance Error Codes Code Fault RemedyCode Water Quality Trouble Shooting for Common IssuesAccessing Operating Information Flushing the Heat Exchanger Error Code LC or Circulating PumpInstallation Instructions General InstructionsClearances from Appliance Attachment of the Water HeaterGeneral Instructions Electrical ConnectionGas Piping Pipe Sizing Procedure Example Isolation Valves Installation Instructions Pressure Relief Valve Installation InstructionsPressure Relief Valve Maintenance Water PipingFreeze Protection Piping RequirementsPressure Relief Valve Requirements Manual draining of the water heater When the water heater or external piping has frozenFreeze Protection Freeze Protection Piping KEYRecommended Piping for Basic Installation Rinnai Water HeaterRecommended Piping for Circulation Systems For this applicationCondensate Venting InstructionsIntake / Exhaust Guidelines Maximum Vent Length Vent Products Manufacturer Product PartsDescription Canadian Installations US Installations Flue Terminal Clearances ANS Z21.10.3, CSAAdditional Clearances Vent Terminal Inside CornerFlue Installation Concentric Venting RL75i, RL94i Flue Installation R98LSi, R98LSi-ASME Air Intake AssemblyExhaust Pipe Assembly Venting Clearances to CombustiblesHorizontal with Concentric Termination Vertical TerminationsConnecting Multiple Water Heaters High Altitude InstallationsNumber Connected Accessories Necessary Water Heaters GuidelinesCanada only Temperature Controller Installation ConfigurationsLocation Cable Lengths and SizeMounting the Controller Outline of RemoteFor Your Safety Read Before Operating Operating InstructionsOutlet Flow Data Technical DataPressure Drop Curve Temperature Setting ReplacementSpace Heating PumpsDimensions RL75i, RL94i R98LSi, R98LSi-ASMELadder Diagram for RL75i and RL94i Ladder Diagram for R98LSi and R98LSi-ASME HOTConsumer Support Warranty InformationLimited Warranty What will Rinnai do? State Regulations Important In the State of Massachusetts 248 CMR 4.00Instructions d’installation Instructions dutilisationInstructions dutilisation Temp. d’eauModel Plages de température disponible ºF Plages de température avec un contrôleur de températureOptions de température sans contrôleur à distance Entretien NettoyageInstructions générales Écartements par rapport à lappareil Fixation du chauffe-eauInstructions générales Installation à altitude élevéeTuyauterie de gaz Tuyauterie deau Valve à Bille / Valve de dégagement de pression RL75i, RL94iQualité de leau Soupape de sûretéTuyauterie recommandée pour installation de base LégendeCondensat Instructions de ventilationConsignes pour aspiration/évacuation Longueur maximum de ventilation 12.5 m 10.7 mHorizontale Produits de ventilationConstructeur Produit Pièces Espacements pour terminaison de cheminée ANS Z21.10.3, CSA Nest PAS PermiseInstallation de conduit de cheminée RL75i, RL94i Installation de conduit de cheminée R98LSi, R98LSi-ASME Ensemble de prise dairMontage du tuyau dévacuation Terminaisons horizontalesTerminaison horizontale concentrique Terminaisons verticalesInstructions dutilisation VanneMa ualmanuelleValveDiagramme en escalier RL75i, RL94i PhaseDiagramme en escalier R98LSi, R98LSiASME Phase TRE NEU RALSupport à la clientèle Informations sur la garantieQuest-ce qui est couvert ? Combien de temps dure la couverture ?Que fait Rinnai pour exercer la garantie ? VB Series Indoor LS Manual VB Series Indoor LS Manual VB Series Indoor LS Manual VB2528FFU VB2735FFU VA3237FFU