Rinnai RL75I, RL94I installation manual Specifications, RL75i RL94i R98LSi

Page 3

Specifications

Model

 

RL75i

RL94i

 

R98LSi

 

R98LSi-ASME

 

 

 

 

 

 

 

 

 

Minimum Gas Consumption Btu/h

9,900 (NG)

 

 

19,000

 

10,300 (LPG)

 

 

 

 

 

 

 

 

 

 

Maximum Gas Consumption Btu/h

180,000

199,000 (NG)

 

 

237,000

 

190,000 (LP)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Hot water capacity (Min - Max) *

0.4 - 7.5 GPM

0.4 - 9.4 GPM

 

0.6 - 9.8 GPM

 

(1.5 - 28.5 L/min)

(1.5 - 35.5 L/min)

 

(2.4 - 37 L/min)

 

 

 

Hot water capacity (45°F rise)

6.6 GPM

7.1 GPM

 

 

8.5 GPM

 

(25.0 L/min)

(27.0 L/min)

 

(32.2 L/min)

 

 

 

 

 

 

 

 

 

 

 

 

 

Default Temperature Setting (no controller)

 

120º F (49º C)

 

 

 

Temperature Controller Default Setting

 

104º F (40º C)

 

 

 

 

 

 

 

 

 

 

 

Maximum Temp Setting (commercial **)

160º F (71º C)

 

 

185º F (85º C)

 

Maximum Temp Setting (residential)

Selectable at 120º F (49º C) or at 140º F

 

140º F (60º C)

see Temperature Ranges for more information

(60º C)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Minimum Temperature Setting

 

98º F (37º C)

 

 

 

Weight

 

51 lb (23 kg)

53 lb (24 kg)

 

55 lb (25 kg)

 

Efficiency

 

Energy Factor: 0.82

 

Thermal Efficiency:

84.0%

Noise level

 

 

49 dB

 

 

 

 

 

Normal

76 W

83 W

 

 

99 W

 

Electrical Consumption

Standby

 

2 W

 

 

 

 

 

Anti-frost Protection

184 W

 

 

116 W

 

By-Pass Control

 

Fixed

 

 

Electronic

 

 

 

Minimum Gas Supply

Natural Gas

 

5.0 inch W.C.

 

 

 

Pressure

Propane

 

8.0 inch W.C.

 

 

 

Maximum Gas Supply

Natural Gas

 

10.5 inch W.C.

 

 

 

Pressure

Propane

 

13.5 inch W.C.

 

 

 

Type of Appliance

 

Direct Vent, Temperature controlled continuous flow gas hot water system.

Operation

 

With or without remote controls, mounted in kitchen, bathroom, etc.

Approved Gas Type

 

Natural Gas or Propane - Ensure unit matches gas type supplied at the installation

Connections

 

Gas Supply: 3/4" MNPT, Cold Water Inlet: 3/4" MNPT, Hot Water Outlet: 3/4" MNPT

Ignition System

 

 

Direct Electronic Ignition

 

 

 

Electric Connections

 

Appliance: AC 120 Volts, 60Hz. Remote Control: DC 12 Volts (Digital)

 

 

 

 

 

 

 

Water Temperature Control

 

Simulation Feedforward and Feedback.

 

Water Supply Pressure

 

Minimum Water Pressure: 20 PSI (Recommended 30-80 PSI for maximum

 

 

 

 

 

 

 

 

Maximum Water Supply Pressure

 

150 PSI

 

 

 

Remote Control Cable

 

Non-Polarized Two Core Cable (Minimum 22 AWG)

 

 

 

 

 

 

 

 

Energy Star Qualified

 

Yes

Yes

 

No (not applicable)

 

 

 

 

 

 

 

 

 

Certified for installation in manufactured (mobile)

Yes

Yes

 

No

 

 

No

homes

 

 

 

 

 

 

 

 

 

 

 

 

*Minimum flow may vary slightly depending on the temperature setting and the inlet water temperature.

**for commercial and hydronic applications requiring higher temperatures

Rinnai is continually updating and improving products. Therefore, specifications are subject to change without prior notice.

The maximum inlet gas pressure must not exceed the value specified by the manufacturer. The minimum value listed is for the purpose of input adjustment.

VB Series Indoor LS Manual

3

Image 3
Contents REU-VB2528FFUD-US Table of Contents RL75i RL94i R98LSi SpecificationsDescription of Operation Consumer Safety InformationSafety Definitions Safety Behaviors and Practices Safety FeaturesMC-91-1US & MCC-91-1US Temperature ControllerMC-91 MCC-91 MC-100 BC-100 MC-502 Description Features Available on Temperature ControllersFeatures Operating InstructionsHow to Set the Temperature Temperature Controller SettingsModel Temperature Settings Available ºF MCC-91 Temperature Controller Temperature Options Without a Temperature ControllerSetting the Sound Volume Voice Prompt Re-setting the Maximum Temperature RL75 and RL94 onlyUsing the Water Smart / Bath Fill Function Setting the Water VolumeOverview Models MC-91 and MCC-91 Setting Controller to MuteSetting the Clock Filling the TubMaintenance Code Fault Remedy Error CodesCode Trouble Shooting for Common Issues Accessing Operating InformationWater Quality Circulating Pump Flushing the Heat Exchanger Error Code LC orGeneral Instructions Installation InstructionsAttachment of the Water Heater Clearances from ApplianceElectrical Connection Gas PipingGeneral Instructions Pipe Sizing Procedure Example Water Piping Isolation Valves Installation InstructionsPressure Relief Valve Installation Instructions Pressure Relief Valve MaintenancePiping Requirements Pressure Relief Valve RequirementsFreeze Protection When the water heater or external piping has frozen Freeze ProtectionManual draining of the water heater KEY Freeze Protection PipingRinnai Water Heater Recommended Piping for Basic InstallationFor this application Recommended Piping for Circulation SystemsVenting Instructions Intake / Exhaust GuidelinesCondensate Maximum Vent Length Manufacturer Product Parts Vent ProductsFlue Terminal Clearances ANS Z21.10.3, CSA Description Canadian Installations US InstallationsInside Corner Additional Clearances Vent TerminalFlue Installation Concentric Venting RL75i, RL94i Venting Clearances to Combustibles Flue Installation R98LSi, R98LSi-ASMEAir Intake Assembly Exhaust Pipe AssemblyVertical Terminations Horizontal with Concentric TerminationGuidelines Connecting Multiple Water HeatersHigh Altitude Installations Number Connected Accessories Necessary Water HeatersCanada only Cable Lengths and Size Temperature Controller InstallationConfigurations LocationOutline of Remote Mounting the ControllerOperating Instructions For Your Safety Read Before OperatingTechnical Data Pressure Drop CurveOutlet Flow Data Pumps Temperature SettingReplacement Space HeatingRL75i, RL94i R98LSi, R98LSi-ASME DimensionsLadder Diagram for RL75i and RL94i HOT Ladder Diagram for R98LSi and R98LSi-ASMEWarranty Information Limited WarrantyConsumer Support What will Rinnai do? Important In the State of Massachusetts 248 CMR 4.00 State RegulationsInstructions dutilisation Instructions d’installationTemp. d’eau Instructions dutilisationPlages de température avec un contrôleur de température Options de température sans contrôleur à distanceModel Plages de température disponible ºF Nettoyage EntretienInstructions générales Fixation du chauffe-eau Écartements par rapport à lappareilInstallation à altitude élevée Tuyauterie de gazInstructions générales Valve à Bille / Valve de dégagement de pression RL75i, RL94i Tuyauterie deauSoupape de sûreté Qualité de leauLégende Tuyauterie recommandée pour installation de baseInstructions de ventilation Consignes pour aspiration/évacuationCondensat 12.5 m 10.7 m Longueur maximum de ventilationProduits de ventilation Constructeur Produit PiècesHorizontale Nest PAS Permise Espacements pour terminaison de cheminée ANS Z21.10.3, CSAInstallation de conduit de cheminée RL75i, RL94i Terminaisons horizontales Installation de conduit de cheminée R98LSi, R98LSi-ASMEEnsemble de prise dair Montage du tuyau dévacuationTerminaisons verticales Terminaison horizontale concentriqueVanneMa ualmanuelleValve Instructions dutilisationPhase Diagramme en escalier RL75i, RL94iPhase TRE NEU RAL Diagramme en escalier R98LSi, R98LSiASMECombien de temps dure la couverture ? Support à la clientèleInformations sur la garantie Quest-ce qui est couvert ?Que fait Rinnai pour exercer la garantie ? VB Series Indoor LS Manual VB Series Indoor LS Manual VB Series Indoor LS Manual VB2528FFU VB2735FFU VA3237FFU