Home Automation INC. Omni IIe, HOME AUTOMATION About ALC, House Codes, ALC Module Types, Page

Page 27

When set to RadioRA, the Omni IIe controller can:

¾Send commands (on, off, and level) to individual Switches and Dimmers

¾Receive status (on and off) from individual Switches and Dimmers

¾Receive commands when buttons are pressed on Master Controls

¾Execute Phantom Button commands

About ALC

ALC is intended for installation in homes, which have been pre-wired for installation of ALC system products. Omni IIe controls lights and appliances by sending commands over the ALC signal wiring to ALC Switch Modules. ALC Switches communicate with the Omni IIe over low voltage signal wire. They are two-way devices, so the controller always knows the actual status of the switch. In addition, ALC switches can be used to set scenes by triggering macros in Omni IIe.

When ALC Lighting Control Modules are being used, it is also possible to "ramp" the lighting level of an ALC Dimmer Switch to a new level at a controllable ramp rate.

ALC Module Types

The ALC modules types are: Dimmer Switch, Relay Switch, Slave Switch, Program Switch, and 4-Button Scene Switch Modules.

About X-10

The Omni IIe controls lights and appliances by sending commands over your existing electrical wiring to special switches, outlets, receptacles, and modules, collectively referred to as X-10. Each module (or group of modules) is assigned a House Code and a Unit Number so that the Omni IIe can control the modules individually. When a module hears a command from the Omni IIe for its house code and unit number, it executes the command.

There are 3 different X-10 formats: Standard X-10 (Preset Dim), Extended X-10 (Extended Level), and Compose.

Any module that is "X-10 Compatible" will work with the Omni IIe. The modules come in various types.

House Codes

Omni IIe can control up to 64 lighting and appliance devices. Each device (switches, modules, and keypad) has its own Unit Number (1-64). Omni IIe groups devices by “House Code”, which consists of 16 consecutive unit numbers, starting at Unit 1. Each “House Code” can be configured to a different lighting protocol format such as: Standard X-10, Extended X-10, Lightolier Compose, UPB (open UPB format where you can use the programming capability in the Omni IIe controller to communicate with the UPB network), Lutron RadioRA, CentraLite, or HAI Lighting Control (HLC).

Different lighting devices can not share the same House Code. However, different lighting devices can coexist on an Omni IIe system as long as they are on separate House Codes. For example:

House Code 1 (Units 1-16) = HLC

House Code 2 (Units 17-32) = UPB

House Code 3 (Units 33-48) = X-10 Extended

House Code 4 (Units 49-64) = CentraLite

Page 19

Image 27
Contents Document Number 20R00-50Rev. January HOME AUTOMATION, INCAll Rights Reserved Copyright 2001-2006Home Automation, IncContents INTRODUCTIONOVERALL DESCRIPTION SECURITY SYSTEM OPERATIONCONTROL TELEPHONE CONTROL PC AccessSETUP APPENDIX A - DIAL OUT PLANNER UNDERWRITERS LABORATORIES REQUIREMENTSFEDERAL COMMUNICATION COMMISSION NOTICE CANADIAN INDUSTRY CANADA NOTICEPage INTRODUCTION Underwriters Laboratories UL ListingPage 2- DAY OVERALL DESCRIPTIONConsole Operation 1- OFF7- CONSOLE LED Normal Top-LevelDisplayDisplay Menus 6- UP ARROWTo silence the beeper, press the * key Error BeepsMain Menu Trouble BeepsConfirmation Beep Omni IIe MaintenanceCancel Areas1 = DAY SECURITY SYSTEM OPERATIONArming the Security System 0 = OFF4 = VACATION Using Shortcut Keys2 = NIGHT 3 = AWAYRestoring Zones 9 = RESTOREQuick Arm Bypassing Zones#=GOTO What To Do When You Come HomeWhat Happens When the Alarm is Activated Burglar Alarm ActivatedPage Fire Alarm ActivatedGas Alarm Activated Emergency KeysPolice Emergency Duress Code Entered or Duress Alarm ActivatedAlarm Reset Alarm CancelPage Trouble IndicationsCodes Master CodeManager Code Panic SwitchesDuress Code Area ArmingPage GOTO AreaPage Testing Your SystemPage Control CommandsCONTROL About UPBAbout Rooms When set to UPB, the Omni IIe controller canRoom Controller LED Indicators HAI Lighting Control HLC FormatPage About Lutron RadioRAAbout House Controllers About CentraLiteHouse Codes When set to RadioRA, the Omni IIe controller canAbout ALC AboutOmni IIe Unit Numbers Unit NumbersScrolling Through Names Controlling UnitsControlling CentraLite Units Page Configuring Lighting Scenes in an HLC RoomStep OperationControlling RadioRA Units Controlling ALC or X-10UnitsPage Ramp Command ALC Controlling Compose UnitsPage Internal Flags Timed CommandsScene Command Compose Status of a UnitWHEN ALL ON PHANTOM BUTTON 16 ON Controlling OutputsAll On / Off WHEN ALL ON LINK 50 ON WHEN ALL OFF LINK 50 OFFScene All Lights OnAll Off Leviton Scene ControlScene Off Command Scene CommandsScene Set Command Scene On CommandExecuting CentraLite Scenes Setting a Link Lighting ScenesActivating and Deactivating Links Executing Phantom ButtonsDinner for Two Button ButtonsTemperature Control Leave for Work ButtonPage HAI RC-SeriesThermostatsPage Programmable Energy Saver Modules PESMsPage The following control actions are allowed on PESMsPage Freeze AlarmsIMPORTANT NOTES Indoor and Outdoor TemperaturePage Temperature AlarmsHumidity Temperature Control of AppliancesPage Configuring HLC DevicesConfiguring HLC Devices using an Omni Console StatusStep Operation Setup Mode for HLC DevicesStep Operation Step OperationDEAD - DEAD PHONE LINE ONHK - ON HOOKOFFHK - OFF HOOK RING - RINGINGShow Events Page Event LogMessages Show MessagePage Phone Message Log MessageClear Message Say MessageMSGNAME ENTER MESSAGEPage Remote Phones TELEPHONE CONTROLTelephone Interface In-HousePhonesPage Phone Access Denied - Remote LockoutAlternate Method Main Menu4 - All 1 - Control2 - Security 3 - Button7 - Events When an HAI Communicating Thermostat is enteredWhen a Programmable Energy Saver PESM is entered 6 - StatusPanic Button over the Phone # # # # # # When the HAI Two-WayAudio Module is being used8 - Phone 9 - Good-ByeHow the Omni IIe Voice Dialer Works Emergency Dial-OutDigital Dialer Voice DialerPage What the Omni IIe Voice Dialer DoesWhat You Hear - If Your Omni IIe Calls You Entering the CodeOmni IIe Ethernet Connections PC AccessConnecting to Network via PC Access Built-InEthernet PortController Local NetworkDynamic DNS 192.168.0.101 Hub or HAI Omni IIeRouterPage Local / Wide Area Networki.e i.eAuthority Level SETUPSet Up Codes Access AreasPage Set Up TimeDuress Code TIMEPage Advanced Control Programming ACP1 = Add Programs 2 = Show ProgramsPage MenuEdit Programs 3 = Delete All ProgramsPage Edit Programs When Times ProgramsPage Control Unit / Switch Press Event Buttons Button and Event ProgramsPage UPB 6-ButtonKeypad Corresponding Switch TableSwitch Omni IIeZone Event Buttons All On/Off Event ButtonsPage Page Alarm Event ButtonsUPB Link Event Buttons X-10Event ButtonsMiscellaneous Event Buttons Message Event Buttons Pro-LinkPage Page Edit Program CommandSwitch Press Event Buttons CentraLite Program Control CommandsWHEN LINK 1 ON Porch Light STATUS Unit Toggle CommandProgram Security Commands WHEN U1 SW UNIT 1 LED 3 ONProgram Temperature Commands Program Button CommandsProgram All On / All Off Commands Program Video CommandsPage Program Message CommandsEdit Program Condition Program Control ConditionsProgram Other Conditions Program Security Mode ConditionsProgram Zone Conditions Program Time Clock ConditionsPage SELECT CONDITION NEVERAnswer Outside Call Set Up DialTelephone Access Remote CommandsPage Dial Out NumberDial Out Numbers Dial OrderAudible Exit Delay Set Up ArmingEntry Delay Exit DelayAll On For Alarm Set up MiscellaneousEnable Quick Arm Enable Auto BypassFORMAT Enable Freeze AlarmFlash For Alarm House Codes 1-4FormatHouse Codes 1-4All On Time ClocksPage Page Latitude, Longitude, and Time ZoneZONE NAME Daylight SavingsDESCRIPTION Controller IP AddressController Port Number NUMBERSet Up Names Encryption KeyPage 4=CODE 5=TEMP 6=AREA 8=MSG↑ Set Up VoiceSet Up Address SET UP VOICE 1=CTRL 2=ZONE 3=BTTN ↓UNDERWRITERS LABORATORIES REQUIREMENTS FIRE ESCAPE PLANNINGPage Page FEDERAL COMMUNICATION COMMISSION NOTICECANADIAN INDUSTRY CANADA NOTICE IF YOU HAVE TROUBLE WITH YOUR PHONESPage APPENDIX A - DIAL OUT PLANNER Omni IIe Voice Dial-OutPlannerPage Page INSTRUCTIONS TO CALLED PARTYCODE CHAR APPENDIX B - TEXT DESCRIPTION CHARACTER CODESCODE CHAR CODE CHARCODE APPENDIX C - VOICE DESCRIPTION CODESCODE DESCRIPTIONDESCRIPTION CODEDESCRIPTION CODEDESCRIPTION CODEDESCRIPTION CODEPage CODE DESCRIPTIONCODE DESCRIPTION CODE DESCRIPTIONPage HAI New Orleans, LA U S A NOTE TO INSTALLER