Button and Event Programs

Selecting 2 (BUTTON), from the "Edit When" menu, sets up a program to be activated when a macro button is executed or an event occurs. The user is prompted to specify the button/event that activates the program:

BUTTON:

#=MENU

ENTER BUTTON

A specific macro button may be activated by entering the button number followed by the ' # ' key, or by using the arrow keys to scroll through a list of buttons.

To program specific event buttons (i.e. Front Door Opens, Security Armed Away, Porch Light Turns On, etc.), press the ' # ' key to bring up a menu of event button types:

BUTTON TYPE

1=CTRL 2=SEC 3=ZONE

4=ALL 5=ALARM 6=X-10 7=MISC 8=MSG 9=SWITCH

After the event button is specified, the display returns to the Edit Program menu.

Control Unit / Switch Press Event Buttons

This Event Button is activated upon the following:

When the specified Unit is turned on or off

When the top-rocker or bottom-rocker is pressed on a UPB, RadioRA, or ALC switch

When a button is pressed on a UPB 6-Button or 8-Button Keypad

When a button is pressed on a RadioRA Master Control

When a button is pressed on a ALC 4-Button Scene Switch Module

Press the 1 (CTRL) key to select the "When Command" for a control unit event.

UNIT:

 

ENTER UNIT

The unit may be selected by entering the unit number followed by the ' # ' key or by using the arrow keys to scroll through a list of unit names. Select the desired unit. Next, you are prompted to specify the event that activates the program:

WHEN Porch Light: 0=OFF 1=ON 2=SWITCH

Press the 0 (OFF) key to select when the unit turns off or press the 1 (ON) key to select when the unit turns on (this program is executed whenever the unit is turned off or on).

Press the 2 (SWITCH) key to select only when the top-rocker or bottom-rocker is pressed at a UPB, RadioRA, or ALC Switch (locally at the Switch) or when a button is pressed on a keypad.

SWITCH:

0=OFF 1=ON 2-11=SW1-SW10

Press "0" to select only when the bottom-rocker (off) is pressed on the Switch. Press "1" to select only when the top-rocker (on) is pressed on the Switch. Press "2-9" (see the Corresponding Switch Table) to select when that button is pressed on a keypad.

Press the ' # ' key to enter your selection.

Page 58

Image 66
Contents HOME AUTOMATION, INC Document Number 20R00-50Rev. JanuaryCopyright 2001-2006Home Automation, Inc All Rights ReservedSECURITY SYSTEM OPERATION INTRODUCTIONOVERALL DESCRIPTION ContentsCONTROL PC Access TELEPHONE CONTROLSETUP CANADIAN INDUSTRY CANADA NOTICE UNDERWRITERS LABORATORIES REQUIREMENTSFEDERAL COMMUNICATION COMMISSION NOTICE APPENDIX A - DIAL OUT PLANNERPage INTRODUCTION Underwriters Laboratories UL ListingPage 1- OFF OVERALL DESCRIPTIONConsole Operation 2- DAY6- UP ARROW Normal Top-LevelDisplayDisplay Menus 7- CONSOLE LEDTrouble Beeps Error BeepsMain Menu To silence the beeper, press the * keyAreas Omni IIe MaintenanceCancel Confirmation Beep0 = OFF SECURITY SYSTEM OPERATIONArming the Security System 1 = DAY3 = AWAY Using Shortcut Keys2 = NIGHT 4 = VACATIONBypassing Zones 9 = RESTOREQuick Arm Restoring ZonesBurglar Alarm Activated What To Do When You Come HomeWhat Happens When the Alarm is Activated #=GOTOEmergency Keys Fire Alarm ActivatedGas Alarm Activated PageAlarm Cancel Duress Code Entered or Duress Alarm ActivatedAlarm Reset Police EmergencyMaster Code Trouble IndicationsCodes PageArea Arming Panic SwitchesDuress Code Manager CodeGOTO Area PageTesting Your System PageAbout UPB Control CommandsCONTROL PageHAI Lighting Control HLC Format When set to UPB, the Omni IIe controller canRoom Controller LED Indicators About RoomsAbout CentraLite About Lutron RadioRAAbout House Controllers PageAbout When set to RadioRA, the Omni IIe controller canAbout ALC House CodesControlling Units Unit NumbersScrolling Through Names Omni IIe Unit NumbersOperation Configuring Lighting Scenes in an HLC RoomStep Controlling CentraLite Units PageControlling RadioRA Units Controlling ALC or X-10UnitsPage Ramp Command ALC Controlling Compose UnitsPage Status of a Unit Timed CommandsScene Command Compose Internal FlagsWHEN ALL ON LINK 50 ON WHEN ALL OFF LINK 50 OFF Controlling OutputsAll On / Off WHEN ALL ON PHANTOM BUTTON 16 ONLeviton Scene Control All Lights OnAll Off SceneScene On Command Scene CommandsScene Set Command Scene Off CommandExecuting Phantom Buttons Setting a Link Lighting ScenesActivating and Deactivating Links Executing CentraLite ScenesLeave for Work Button ButtonsTemperature Control Dinner for Two ButtonHAI RC-SeriesThermostats PageProgrammable Energy Saver Modules PESMs PageThe following control actions are allowed on PESMs PageIndoor and Outdoor Temperature Freeze AlarmsIMPORTANT NOTES PageTemperature Control of Appliances Temperature AlarmsHumidity PageStatus Configuring HLC DevicesConfiguring HLC Devices using an Omni Console PageStep Operation Setup Mode for HLC DevicesStep Operation Step OperationRING - RINGING ONHK - ON HOOKOFFHK - OFF HOOK DEAD - DEAD PHONE LINEEvent Log Show Events PageMessages Show MessagePage Say Message Log MessageClear Message Phone MessageMSGNAME ENTER MESSAGEPage In-HousePhones TELEPHONE CONTROLTelephone Interface Remote PhonesMain Menu Phone Access Denied - Remote LockoutAlternate Method Page3 - Button 1 - Control2 - Security 4 - All6 - Status When an HAI Communicating Thermostat is enteredWhen a Programmable Energy Saver PESM is entered 7 - Events9 - Good-Bye When the HAI Two-WayAudio Module is being used8 - Phone Panic Button over the Phone # # # # # #Voice Dialer Emergency Dial-OutDigital Dialer How the Omni IIe Voice Dialer WorksEntering the Code What the Omni IIe Voice Dialer DoesWhat You Hear - If Your Omni IIe Calls You PageBuilt-InEthernet Port PC AccessConnecting to Network via PC Access Omni IIe Ethernet Connections192.168.0.101 Hub or HAI Omni IIeRouter Local NetworkDynamic DNS Controlleri.e Local / Wide Area Networki.e PageAccess Areas SETUPSet Up Codes Authority LevelTIME Set Up TimeDuress Code Page2 = Show Programs Advanced Control Programming ACP1 = Add Programs PageMenu PageEdit Programs 3 = Delete All ProgramsPage Edit Programs When Times ProgramsPage Control Unit / Switch Press Event Buttons Button and Event ProgramsPage Omni IIe Corresponding Switch TableSwitch UPB 6-ButtonKeypadZone Event Buttons All On/Off Event ButtonsPage X-10Event Buttons Alarm Event ButtonsUPB Link Event Buttons PageMiscellaneous Event Buttons Message Event Buttons Pro-LinkPage Program Control Commands Edit Program CommandSwitch Press Event Buttons CentraLite PageWHEN U1 SW UNIT 1 LED 3 ON Unit Toggle CommandProgram Security Commands WHEN LINK 1 ON Porch Light STATUSProgram Video Commands Program Button CommandsProgram All On / All Off Commands Program Temperature CommandsProgram Control Conditions Program Message CommandsEdit Program Condition PageProgram Time Clock Conditions Program Security Mode ConditionsProgram Zone Conditions Program Other ConditionsSELECT CONDITION NEVER PageRemote Commands Set Up DialTelephone Access Answer Outside CallDial Order Dial Out NumberDial Out Numbers PageExit Delay Set Up ArmingEntry Delay Audible Exit DelayEnable Auto Bypass Set up MiscellaneousEnable Quick Arm All On For AlarmHouse Codes 1-4Format Enable Freeze AlarmFlash For Alarm FORMATHouse Codes 1-4All On Time ClocksPage Daylight Savings Latitude, Longitude, and Time ZoneZONE NAME PageNUMBER Controller IP AddressController Port Number DESCRIPTIONSet Up Names Encryption KeyPage SET UP VOICE 1=CTRL 2=ZONE 3=BTTN ↓ Set Up VoiceSet Up Address 4=CODE 5=TEMP 6=AREA 8=MSG↑UNDERWRITERS LABORATORIES REQUIREMENTS FIRE ESCAPE PLANNINGPage FEDERAL COMMUNICATION COMMISSION NOTICE PageCANADIAN INDUSTRY CANADA NOTICE IF YOU HAVE TROUBLE WITH YOUR PHONESPage APPENDIX A - DIAL OUT PLANNER Omni IIe Voice Dial-OutPlannerPage INSTRUCTIONS TO CALLED PARTY PageCODE CHAR APPENDIX B - TEXT DESCRIPTION CHARACTER CODESCODE CHAR CODE CHARDESCRIPTION APPENDIX C - VOICE DESCRIPTION CODESCODE CODECODE CODEDESCRIPTION DESCRIPTIONCODE CODEDESCRIPTION DESCRIPTIONCODE DESCRIPTION CODE DESCRIPTIONCODE DESCRIPTION PagePage NOTE TO INSTALLER HAI New Orleans, LA U S A