Unit Numbers

Unit Numbers

Omni IIe systems have 128 total Unit Numbers. They consist of HLC, UPB, CentraLite, RadioRA, ALC, Compose, and X-10 module unit numbers, hardwire voltage output unit numbers, and internal flag unit numbers as follows:

Omni IIe Unit Numbers

1 - 16

17 - 32

(1 - 31)

33 - 48

49 - 64

(33 – 63)

65 - 72

79 – 128

Module / Output Unit Numbers

HLC Room 1 and 2, UPB Unit ID 1-16, CentraLite loads 1-16, RadioRA Lighting Zones and Master Controls 1-16, or X-10 modules 1 – 16 (House Code X)

HLC Room 3 and 4, UPB Unit ID 17-32, CentraLite loads 17-32, RadioRA Lighting Zones and Master Controls 17-32, or X-10 modules 1 – 16 (House Code X+1)

ALC addresses 1-31, Branch 1 *

HLC Room 5 and 6, UPB Unit ID 33-48, CentraLite loads 33-48, RadioRA Lighting Zones and Master Controls 33-48, or X-10 modules 1 – 16 (House Code X+2)

HLC Room 7 and 8, UPB Unit ID 49-64, CentraLite loads 49-64, RadioRA Lighting Zones and Master Controls 49-64, or X-10 modules 1 – 16 (House Code X+3)

ALC addresses 1-31, Branch 2 *

Voltage Outputs (1-8), Fully Configurable Internal Flags

“X” Represents the House Code setting on the Omni IIe Controller “*” If used

Scrolling Through Names

The Omni IIe stores names for Units, Zones, Buttons, Codes, Temperatures, and Messages so that you don't have to remember that "UNIT 5" is the "DEN LIGHT" and "ZONE 1" is the "FRONT DOOR". In general, any time you enter a unit, zone, button, code, temperature, or message number, you can press the down arrow key to display its name, then use the up and down arrow keys to scroll through the list of other names. This is true when entering commands and programming on the console. Only named items are displayed on an OmniTouch touchscreen.

Controlling Units

The control menu is used when controlling lights and appliances. To enter the control menu, from the top-level display or from the main menu, press the 1 (CTRL) key on the console keypad. Omni IIe will automatically display the first named item in that list. The down arrow key can then be used to scroll through the list, and the ' # ' key is used to select the item. If the specific item number is known, enter the item number followed be the ' # ' key, or scroll up and down among the named items.

After the unit has been selected, press the ' # ' key. The console will display:

Controlling a Room of HLC Lighting

 

Living Room

0=OFF 1=ON 2-5=A-D

Living Room

6=SET#=STA

¾Press 0 (OFF) to turn the selected room off (all lighting loads in the room are turned off).

¾Press 1 (ON) to turn the selected room on (all lighting loads in the room are turned on).

¾Press 2 (A) to set all of the lighting loads in the selected room to their preset levels for Scene A.

¾Press 3 (B) to set all of the lighting loads in the selected room to their preset levels for Scene B.

¾Press 4 (C) to set all of the lighting loads in the selected room to their preset levels for Scene C.

¾Press 5 (D) to set all of the lighting loads in the selected room to their preset levels for Scene D.

¾Press 6 (SET) to set up a lighting scene for the all of the lighting loads in the selected room (On, A-D).

¾Press # (STA) to view the current status of the room.

Page 20

Image 28
Contents HOME AUTOMATION, INC Document Number 20R00-50Rev. JanuaryCopyright 2001-2006Home Automation, Inc All Rights ReservedINTRODUCTION OVERALL DESCRIPTIONSECURITY SYSTEM OPERATION ContentsCONTROL PC Access TELEPHONE CONTROLSETUP UNDERWRITERS LABORATORIES REQUIREMENTS FEDERAL COMMUNICATION COMMISSION NOTICECANADIAN INDUSTRY CANADA NOTICE APPENDIX A - DIAL OUT PLANNERPage Underwriters Laboratories UL Listing INTRODUCTIONPage OVERALL DESCRIPTION Console Operation1- OFF 2- DAYNormal Top-LevelDisplay Display Menus6- UP ARROW 7- CONSOLE LEDError Beeps Main MenuTrouble Beeps To silence the beeper, press the * keyOmni IIe Maintenance CancelAreas Confirmation BeepSECURITY SYSTEM OPERATION Arming the Security System0 = OFF 1 = DAYUsing Shortcut Keys 2 = NIGHT3 = AWAY 4 = VACATION9 = RESTORE Quick ArmBypassing Zones Restoring ZonesWhat To Do When You Come Home What Happens When the Alarm is ActivatedBurglar Alarm Activated #=GOTOFire Alarm Activated Gas Alarm ActivatedEmergency Keys PageDuress Code Entered or Duress Alarm Activated Alarm ResetAlarm Cancel Police EmergencyTrouble Indications CodesMaster Code PagePanic Switches Duress CodeArea Arming Manager CodeGOTO Area PageTesting Your System PageControl Commands CONTROLAbout UPB PageWhen set to UPB, the Omni IIe controller can Room Controller LED IndicatorsHAI Lighting Control HLC Format About RoomsAbout Lutron RadioRA About House ControllersAbout CentraLite PageWhen set to RadioRA, the Omni IIe controller can About ALCAbout House CodesUnit Numbers Scrolling Through NamesControlling Units Omni IIe Unit NumbersConfiguring Lighting Scenes in an HLC Room StepOperation Controlling CentraLite Units PageControlling ALC or X-10Units Controlling RadioRA UnitsPage Controlling Compose Units Ramp Command ALCPage Timed Commands Scene Command ComposeStatus of a Unit Internal FlagsControlling Outputs All On / OffWHEN ALL ON LINK 50 ON WHEN ALL OFF LINK 50 OFF WHEN ALL ON PHANTOM BUTTON 16 ONAll Lights On All OffLeviton Scene Control SceneScene Commands Scene Set CommandScene On Command Scene Off CommandSetting a Link Lighting Scenes Activating and Deactivating LinksExecuting Phantom Buttons Executing CentraLite ScenesButtons Temperature ControlLeave for Work Button Dinner for Two ButtonHAI RC-SeriesThermostats PageProgrammable Energy Saver Modules PESMs PageThe following control actions are allowed on PESMs PageFreeze Alarms IMPORTANT NOTESIndoor and Outdoor Temperature PageTemperature Alarms HumidityTemperature Control of Appliances PageConfiguring HLC Devices Configuring HLC Devices using an Omni ConsoleStatus PageSetup Mode for HLC Devices Step OperationStep Operation Step OperationONHK - ON HOOK OFFHK - OFF HOOKRING - RINGING DEAD - DEAD PHONE LINEEvent Log Show Events PageShow Message MessagesPage Log Message Clear MessageSay Message Phone MessageENTER MESSAGE MSGNAMEPage TELEPHONE CONTROL Telephone InterfaceIn-HousePhones Remote PhonesPhone Access Denied - Remote Lockout Alternate MethodMain Menu Page1 - Control 2 - Security3 - Button 4 - AllWhen an HAI Communicating Thermostat is entered When a Programmable Energy Saver PESM is entered6 - Status 7 - EventsWhen the HAI Two-WayAudio Module is being used 8 - Phone9 - Good-Bye Panic Button over the Phone # # # # # #Emergency Dial-Out Digital DialerVoice Dialer How the Omni IIe Voice Dialer WorksWhat the Omni IIe Voice Dialer Does What You Hear - If Your Omni IIe Calls YouEntering the Code PagePC Access Connecting to Network via PC AccessBuilt-InEthernet Port Omni IIe Ethernet ConnectionsLocal Network Dynamic DNS192.168.0.101 Hub or HAI Omni IIeRouter ControllerLocal / Wide Area Network i.ei.e PageSETUP Set Up CodesAccess Areas Authority LevelSet Up Time Duress CodeTIME PageAdvanced Control Programming ACP 1 = Add Programs2 = Show Programs PageMenu Page3 = Delete All Programs Edit ProgramsPage Times Programs Edit Programs WhenPage Button and Event Programs Control Unit / Switch Press Event ButtonsPage Corresponding Switch Table SwitchOmni IIe UPB 6-ButtonKeypadAll On/Off Event Buttons Zone Event ButtonsPage Alarm Event Buttons UPB Link Event ButtonsX-10Event Buttons PageMessage Event Buttons Pro-Link Miscellaneous Event ButtonsPage Edit Program Command Switch Press Event Buttons CentraLiteProgram Control Commands PageUnit Toggle Command Program Security CommandsWHEN U1 SW UNIT 1 LED 3 ON WHEN LINK 1 ON Porch Light STATUSProgram Button Commands Program All On / All Off CommandsProgram Video Commands Program Temperature CommandsProgram Message Commands Edit Program ConditionProgram Control Conditions PageProgram Security Mode Conditions Program Zone ConditionsProgram Time Clock Conditions Program Other ConditionsSELECT CONDITION NEVER PageSet Up Dial Telephone AccessRemote Commands Answer Outside CallDial Out Number Dial Out NumbersDial Order PageSet Up Arming Entry DelayExit Delay Audible Exit DelaySet up Miscellaneous Enable Quick ArmEnable Auto Bypass All On For AlarmEnable Freeze Alarm Flash For AlarmHouse Codes 1-4Format FORMATTime Clocks House Codes 1-4All OnPage Latitude, Longitude, and Time Zone ZONE NAMEDaylight Savings PageController IP Address Controller Port NumberNUMBER DESCRIPTIONEncryption Key Set Up NamesPage Set Up Voice Set Up AddressSET UP VOICE 1=CTRL 2=ZONE 3=BTTN ↓ 4=CODE 5=TEMP 6=AREA 8=MSG↑FIRE ESCAPE PLANNING UNDERWRITERS LABORATORIES REQUIREMENTSPage FEDERAL COMMUNICATION COMMISSION NOTICE PageIF YOU HAVE TROUBLE WITH YOUR PHONES CANADIAN INDUSTRY CANADA NOTICEPage Omni IIe Voice Dial-OutPlanner APPENDIX A - DIAL OUT PLANNERPage INSTRUCTIONS TO CALLED PARTY PageAPPENDIX B - TEXT DESCRIPTION CHARACTER CODES CODE CHARCODE CHAR CODE CHARAPPENDIX C - VOICE DESCRIPTION CODES CODEDESCRIPTION CODECODE DESCRIPTIONCODE DESCRIPTIONCODE DESCRIPTIONCODE DESCRIPTIONCODE DESCRIPTION CODE DESCRIPTIONCODE DESCRIPTION PagePage NOTE TO INSTALLER HAI New Orleans, LA U S A