The following control actions are allowed on PESMs:
•Turn Energy Saver On and Off
•Turn Energy Saver On and Off for a specified time
•Set heating setpoint
•Set cooling setpoint
You can turn the energy saver on, off, use a timed on/off, and change the Heat and Cool temperatures from the console or by telephone. Commands can also be programmed so that they occur by time schedule or by event, such as security mode change. For example, the system can be set up to turn the energy saver(s) On and make the Heat setback temperature 65 degrees and the Cool setback temperature 80 degrees when the alarm system is put in the Away mode. Another program can turn the energy saver(s) off (to resume normal operation of the HVAC system) at 4:30 P.M. on weekdays to make the house comfortable before arriving home. Different setback temperatures could be set for the Night mode.
To set up your thermostat for use with the energy saver, set it in the appropriate mode and set the temperature to your preference.
NOTE: Your heating and cooling system will always be off if you set your thermostat to Off mode. The PESM cannot turn it back on. The PESM cannot make your system cool below the thermostat's cool setting, or heat above the thermostat's heat setting.
Control actions for temperature sensors:
•Set low setpoint
•Set high setpoint
To enter the temperature menu, from the
TEMPERATURE ZONE:
ENTER TEMPERATURE ZONE ↓
After the ' # ' key is pressed, a menu appropriate for the type of temperature zone is shown.
For Programmable Energy Saver Modules: |
| |
Upstairs |
| 2=HEAT ↓ |
0=OFF | 1=ON | |
Upstairs |
| #=STAT ↑ |
3=COOL | 4=TIME | |
For temperature sensors: |
|
|
Upstairs |
|
|
2=LOW | 3=HIGH | #=STAT |
To set a temperature setpoint, press 2 (HEAT) or 3 (COOL).
For Celsius temperatures, press the ' # ' key prior to entering the temperature to make the number negative. The Celsius temperature may also be specified in 0.5 degree steps if three numeric digits are entered. The third digit adds a .5 to the first two digits if it is any- thing other than zero. Enter a leading zero if necessary.
In additions to setpoint changes, an energy saver may be turned On or Off. It may also be turned On or Off for a specific duration.
To turn the energy saver Off, select 0 (OFF). To turn the energy saver On, select 1 (ON). To turn the energy saver On or Off for a specific duration, select 9 (TIME) prior to selecting On or Off. Enter the time as described under Control - Unit Commands.
Downstairs