Home Automation INC. Omni IIe owner manual Onhk - On Hook, Offhk - Off Hook, Ring - Ringing, Page

Page 45
Image 45
Contents Document Number 20R00-50Rev. January HOME AUTOMATION, INCAll Rights Reserved Copyright 2001-2006Home Automation, IncOVERALL DESCRIPTION INTRODUCTIONSECURITY SYSTEM OPERATION ContentsCONTROL TELEPHONE CONTROL PC AccessSETUP FEDERAL COMMUNICATION COMMISSION NOTICE UNDERWRITERS LABORATORIES REQUIREMENTSCANADIAN INDUSTRY CANADA NOTICE APPENDIX A - DIAL OUT PLANNERPage INTRODUCTION Underwriters Laboratories UL ListingPage Console Operation OVERALL DESCRIPTION1- OFF 2- DAYDisplay Menus Normal Top-LevelDisplay6- UP ARROW 7- CONSOLE LEDMain Menu Error BeepsTrouble Beeps To silence the beeper, press the * keyCancel Omni IIe MaintenanceAreas Confirmation BeepArming the Security System SECURITY SYSTEM OPERATION0 = OFF 1 = DAY2 = NIGHT Using Shortcut Keys3 = AWAY 4 = VACATIONQuick Arm 9 = RESTOREBypassing Zones Restoring ZonesWhat Happens When the Alarm is Activated What To Do When You Come HomeBurglar Alarm Activated #=GOTOGas Alarm Activated Fire Alarm ActivatedEmergency Keys PageAlarm Reset Duress Code Entered or Duress Alarm ActivatedAlarm Cancel Police EmergencyCodes Trouble IndicationsMaster Code PageDuress Code Panic SwitchesArea Arming Manager CodePage GOTO AreaPage Testing Your SystemCONTROL Control CommandsAbout UPB PageRoom Controller LED Indicators When set to UPB, the Omni IIe controller canHAI Lighting Control HLC Format About RoomsAbout House Controllers About Lutron RadioRAAbout CentraLite PageAbout ALC When set to RadioRA, the Omni IIe controller canAbout House CodesScrolling Through Names Unit NumbersControlling Units Omni IIe Unit NumbersStep Configuring Lighting Scenes in an HLC RoomOperation Controlling CentraLite Units PageControlling RadioRA Units Controlling ALC or X-10UnitsPage Ramp Command ALC Controlling Compose UnitsPage Scene Command Compose Timed CommandsStatus of a Unit Internal FlagsAll On / Off Controlling OutputsWHEN ALL ON LINK 50 ON WHEN ALL OFF LINK 50 OFF WHEN ALL ON PHANTOM BUTTON 16 ONAll Off All Lights OnLeviton Scene Control SceneScene Set Command Scene CommandsScene On Command Scene Off CommandActivating and Deactivating Links Setting a Link Lighting ScenesExecuting Phantom Buttons Executing CentraLite ScenesTemperature Control ButtonsLeave for Work Button Dinner for Two ButtonPage HAI RC-SeriesThermostatsPage Programmable Energy Saver Modules PESMsPage The following control actions are allowed on PESMsIMPORTANT NOTES Freeze AlarmsIndoor and Outdoor Temperature PageHumidity Temperature AlarmsTemperature Control of Appliances PageConfiguring HLC Devices using an Omni Console Configuring HLC DevicesStatus PageStep Operation Setup Mode for HLC DevicesStep Operation Step OperationOFFHK - OFF HOOK ONHK - ON HOOKRING - RINGING DEAD - DEAD PHONE LINEShow Events Page Event LogMessages Show MessagePage Clear Message Log MessageSay Message Phone MessageMSGNAME ENTER MESSAGEPage Telephone Interface TELEPHONE CONTROLIn-HousePhones Remote PhonesAlternate Method Phone Access Denied - Remote LockoutMain Menu Page2 - Security 1 - Control3 - Button 4 - AllWhen a Programmable Energy Saver PESM is entered When an HAI Communicating Thermostat is entered6 - Status 7 - Events8 - Phone When the HAI Two-WayAudio Module is being used9 - Good-Bye Panic Button over the Phone # # # # # #Digital Dialer Emergency Dial-OutVoice Dialer How the Omni IIe Voice Dialer WorksWhat You Hear - If Your Omni IIe Calls You What the Omni IIe Voice Dialer DoesEntering the Code PageConnecting to Network via PC Access PC AccessBuilt-InEthernet Port Omni IIe Ethernet ConnectionsDynamic DNS Local Network192.168.0.101 Hub or HAI Omni IIeRouter Controlleri.e Local / Wide Area Networki.e PageSet Up Codes SETUPAccess Areas Authority LevelDuress Code Set Up TimeTIME Page1 = Add Programs Advanced Control Programming ACP2 = Show Programs PagePage MenuEdit Programs 3 = Delete All ProgramsPage Edit Programs When Times ProgramsPage Control Unit / Switch Press Event Buttons Button and Event ProgramsPage Switch Corresponding Switch TableOmni IIe UPB 6-ButtonKeypadZone Event Buttons All On/Off Event ButtonsPage UPB Link Event Buttons Alarm Event ButtonsX-10Event Buttons PageMiscellaneous Event Buttons Message Event Buttons Pro-LinkPage Switch Press Event Buttons CentraLite Edit Program CommandProgram Control Commands PageProgram Security Commands Unit Toggle CommandWHEN U1 SW UNIT 1 LED 3 ON WHEN LINK 1 ON Porch Light STATUSProgram All On / All Off Commands Program Button CommandsProgram Video Commands Program Temperature CommandsEdit Program Condition Program Message CommandsProgram Control Conditions PageProgram Zone Conditions Program Security Mode ConditionsProgram Time Clock Conditions Program Other ConditionsPage SELECT CONDITION NEVERTelephone Access Set Up DialRemote Commands Answer Outside CallDial Out Numbers Dial Out NumberDial Order PageEntry Delay Set Up ArmingExit Delay Audible Exit DelayEnable Quick Arm Set up MiscellaneousEnable Auto Bypass All On For AlarmFlash For Alarm Enable Freeze AlarmHouse Codes 1-4Format FORMATHouse Codes 1-4All On Time ClocksPage ZONE NAME Latitude, Longitude, and Time ZoneDaylight Savings PageController Port Number Controller IP AddressNUMBER DESCRIPTIONSet Up Names Encryption KeyPage Set Up Address Set Up VoiceSET UP VOICE 1=CTRL 2=ZONE 3=BTTN ↓ 4=CODE 5=TEMP 6=AREA 8=MSG↑UNDERWRITERS LABORATORIES REQUIREMENTS FIRE ESCAPE PLANNINGPage Page FEDERAL COMMUNICATION COMMISSION NOTICECANADIAN INDUSTRY CANADA NOTICE IF YOU HAVE TROUBLE WITH YOUR PHONESPage APPENDIX A - DIAL OUT PLANNER Omni IIe Voice Dial-OutPlannerPage Page INSTRUCTIONS TO CALLED PARTYCODE CHAR APPENDIX B - TEXT DESCRIPTION CHARACTER CODESCODE CHAR CODE CHARCODE APPENDIX C - VOICE DESCRIPTION CODESDESCRIPTION CODEDESCRIPTION CODECODE DESCRIPTIONDESCRIPTION CODECODE DESCRIPTIONCODE DESCRIPTION CODE DESCRIPTIONCODE DESCRIPTION PagePage HAI New Orleans, LA U S A NOTE TO INSTALLER