UPB Link Event Buttons
When a program is created that uses “When Link On” as the trigger, the program will execute when a “Link Activate”, “Link Goto” (as long as the result of the Goto command is not “0”), or “Link Fade Start” (as long as the result to the Fade command is not “0”) message is received.
When a program is created that uses “When Link Off” as the trigger, the program will execute when a “Link Deactivate” or “Link Goto” (where the result of the Goto command is “0”) message is received.
Using HAI PC Access Software, you can create a program that uses “When Link Fade Stop” as the trigger. When this trigger is used, the program will execute when the “Link Fade Stop” message is received.
Alarm Event Buttons
Pressing the 5 (ALARM) key allows you to specify an event button activated upon the occurrence of an alarm. You are first prompted to select the type of alarm:
SELECT ALARM TYPE | ↓ |
ANY TYPE |
The arrow keys are used to select from a list of alarm types:
•ANY ALARM
•BURGLARY ALARM
•FIRE ALARM
•GAS ALARM
•AUXILIARY ALARM
•FREEZE ALARM
•WATER ALARM
•DURESS ALARM
•TEMPERATURE ALARM
Press the ' # ' key when the desired alarm type is shown. You are then prompted to specify the area, if area arming is being used:
AREA: | 0=ALL ↓ |
ENTER AREA |
T he area number should be entered followed by the ' # ' key, or the arrow keys may be used to scroll through a list of areas.
X-10 Event Buttons
Pressing the 6
You are then prompted to enter the