House Codes 1-4 All On
This feature allows you to choose if House Code
HC 1 | ALL ON: | 1 |
0=NO | 1=YES |
|
The default setting for HC
Notes:
1.When configured, each House Code will affect 2 rooms of HLC lighting (i.e. HC 1 ALL ON affects Room 1 and 2).
2.When the House Code is configured as UPB, RadioRA, or CentraLite, “House Code All On” does not affect the state of the installed devices; however, if this setup item is set to “Yes”, Omni IIe will change the status of all units on that House Code to “On” (even though it doesn’t explicitly send an All On command to those units). If the “House Code All On” setup item is set to “No”, Omni IIe will not change the status of units on that House Code.
Time Clocks
There are three Time Clocks in the system are used to conditionalize programs. They are used solely to define time periods during the week when certain programs should be enabled or disabled to execute.
TIME CLOCK 1 ON
TIME CLOCK 1 OFF
Specify the on and off times for each Time Clock - See Set Up Codes.
TIME CLOCK 1 ON TIME: 12:00 AM MTWTFSS #=CHNG
TIME CLOCK 1 OFF TIME
--NEVER #=CHNG
For example, it may be desirable to conditionalize certain programs to execute only during a normal Monday - Friday 9:00 AM - 5:00 PM work week.
The default for Time Clock 1 ON is 12:00 AM MTWTFSS, and the default for Time Clock 1 OFF is Never, so that Time Clock 1 is always Enabled.
TIME CLOCK 2 ON
TIME CLOCK 2 OFF
TIME CLOCK 3 ON
TIME CLOCK 3 OFF
Time Clocks 2 and 3 is entered into the system and set for time and dates exactly like the settings for Time Clock 1.
Page 74