Home Automation HOME AUTOMATION Good-Bye, Panic Button over the Phone # # # # # #, Page

Page 54

8 - Phone

This command allows you to record and verify the address. If an optional HAI Two-Way Audio Module is being used, this command also allows paging and listening to the premises.

Press 8 from the MAIN MENU to get to the PHONE menu.

"PHONE - PLEASE CHOOSE: [3 INTERIOR]

8 PLAY ADDRESS, 9 RECORD ADDRESS *: CANCEL."

To play the current address, press the 8 key.

To record the address, press the 9 key and enter the Master code.

"RECORD ADDRESS - [BEEP]

At the [BEEP], record your name and address.

"ADDRESS IS: (OMNI IIe PLAYS ADDRESS)."

Note: The address is used only for the VOICE dial out feature.

When the HAI Two-Way Audio Module is being used:

To talk or listen to the premises, press the 3 key.

"PLEASE CHOOSE: 2 TALK, 8 LISTEN, *: CANCEL."

-If no key is pressed, Omni IIe will automatically switch to listen mode.

To talk to someone at the premises, press the 2 key.

To listen to the premises, press the 8 key.

-You cannot talk to anyone on premises in listen mode and you cannot listen to the premises while in the talk mode.

9 - Good-Bye

Press 9 from the MAIN MENU.

The Omni IIe will say, "GOOD-BYE" and hang up.

From an in-house phone, the dial tone will return. From a remote phone, you will hear a click as the Omni IIe hangs up. It is recommended that you press 9 to terminate a remote call. If you don't, the Omni IIe will hang up anyway after about 15 seconds.

Panic Button over the Phone (# # # # # #)

On an in-house phone only, you can activate the Police Emergency keys by picking up the phone and pressing the # key 6 times. This activates the sounder immediately.

The first # that you press logs you in, as usual, then the next 5 presses of the # key activate the alarm. If you are already logged into your system, then it takes only 5 presses of the # key to activate the emergency alarm. To prevent accidental activation of the panic feature over the phone, you must press the # key 5 times, all at once. If you pause for more than 2 seconds, or press any other key, the panic activation is canceled. The Omni IIe will say "CANCEL".

Note that the Panic Button over the Phone feature only works if you are logged into the system. In an emergency, if you wish to set off the alarm, simply pick up the phone and repeatedly press the # key until the alarm sounds. Be aware that, under some circumstances, it may be smarter to dial 911 or your police department directly. Also be aware that your telephone will be unusable while the Omni IIe dials out.

Page 46

Image 54
Contents HOME AUTOMATION, INC Document Number 20R00-50Rev. JanuaryCopyright 2001-2006Home Automation, Inc All Rights ReservedSECURITY SYSTEM OPERATION INTRODUCTIONOVERALL DESCRIPTION ContentsCONTROL PC Access TELEPHONE CONTROLSETUP CANADIAN INDUSTRY CANADA NOTICE UNDERWRITERS LABORATORIES REQUIREMENTSFEDERAL COMMUNICATION COMMISSION NOTICE APPENDIX A - DIAL OUT PLANNERPage INTRODUCTION Underwriters Laboratories UL ListingPage 1- OFF OVERALL DESCRIPTIONConsole Operation 2- DAY6- UP ARROW Normal Top-LevelDisplayDisplay Menus 7- CONSOLE LEDTrouble Beeps Error BeepsMain Menu To silence the beeper, press the * keyAreas Omni IIe MaintenanceCancel Confirmation Beep0 = OFF SECURITY SYSTEM OPERATIONArming the Security System 1 = DAY3 = AWAY Using Shortcut Keys2 = NIGHT 4 = VACATIONBypassing Zones 9 = RESTOREQuick Arm Restoring ZonesBurglar Alarm Activated What To Do When You Come HomeWhat Happens When the Alarm is Activated #=GOTOEmergency Keys Fire Alarm ActivatedGas Alarm Activated PageAlarm Cancel Duress Code Entered or Duress Alarm ActivatedAlarm Reset Police EmergencyMaster Code Trouble IndicationsCodes PageArea Arming Panic SwitchesDuress Code Manager CodeGOTO Area PageTesting Your System PageAbout UPB Control CommandsCONTROL PageHAI Lighting Control HLC Format When set to UPB, the Omni IIe controller canRoom Controller LED Indicators About RoomsAbout CentraLite About Lutron RadioRAAbout House Controllers PageAbout When set to RadioRA, the Omni IIe controller canAbout ALC House CodesControlling Units Unit NumbersScrolling Through Names Omni IIe Unit NumbersOperation Configuring Lighting Scenes in an HLC RoomStep Controlling CentraLite Units PageControlling RadioRA Units Controlling ALC or X-10UnitsPage Ramp Command ALC Controlling Compose UnitsPage Status of a Unit Timed CommandsScene Command Compose Internal FlagsWHEN ALL ON LINK 50 ON WHEN ALL OFF LINK 50 OFF Controlling OutputsAll On / Off WHEN ALL ON PHANTOM BUTTON 16 ONLeviton Scene Control All Lights OnAll Off SceneScene On Command Scene CommandsScene Set Command Scene Off CommandExecuting Phantom Buttons Setting a Link Lighting ScenesActivating and Deactivating Links Executing CentraLite ScenesLeave for Work Button ButtonsTemperature Control Dinner for Two ButtonHAI RC-SeriesThermostats PageProgrammable Energy Saver Modules PESMs PageThe following control actions are allowed on PESMs PageIndoor and Outdoor Temperature Freeze AlarmsIMPORTANT NOTES PageTemperature Control of Appliances Temperature AlarmsHumidity PageStatus Configuring HLC DevicesConfiguring HLC Devices using an Omni Console PageStep Operation Setup Mode for HLC DevicesStep Operation Step OperationRING - RINGING ONHK - ON HOOKOFFHK - OFF HOOK DEAD - DEAD PHONE LINEEvent Log Show Events PageMessages Show MessagePage Say Message Log MessageClear Message Phone MessageMSGNAME ENTER MESSAGEPage In-HousePhones TELEPHONE CONTROLTelephone Interface Remote PhonesMain Menu Phone Access Denied - Remote LockoutAlternate Method Page3 - Button 1 - Control2 - Security 4 - All6 - Status When an HAI Communicating Thermostat is enteredWhen a Programmable Energy Saver PESM is entered 7 - Events9 - Good-Bye When the HAI Two-WayAudio Module is being used8 - Phone Panic Button over the Phone # # # # # #Voice Dialer Emergency Dial-OutDigital Dialer How the Omni IIe Voice Dialer WorksEntering the Code What the Omni IIe Voice Dialer DoesWhat You Hear - If Your Omni IIe Calls You PageBuilt-InEthernet Port PC AccessConnecting to Network via PC Access Omni IIe Ethernet Connections192.168.0.101 Hub or HAI Omni IIeRouter Local NetworkDynamic DNS Controlleri.e Local / Wide Area Networki.e PageAccess Areas SETUPSet Up Codes Authority LevelTIME Set Up TimeDuress Code Page2 = Show Programs Advanced Control Programming ACP1 = Add Programs PageMenu PageEdit Programs 3 = Delete All ProgramsPage Edit Programs When Times ProgramsPage Control Unit / Switch Press Event Buttons Button and Event ProgramsPage Omni IIe Corresponding Switch TableSwitch UPB 6-ButtonKeypadZone Event Buttons All On/Off Event ButtonsPage X-10Event Buttons Alarm Event ButtonsUPB Link Event Buttons PageMiscellaneous Event Buttons Message Event Buttons Pro-LinkPage Program Control Commands Edit Program CommandSwitch Press Event Buttons CentraLite PageWHEN U1 SW UNIT 1 LED 3 ON Unit Toggle CommandProgram Security Commands WHEN LINK 1 ON Porch Light STATUSProgram Video Commands Program Button CommandsProgram All On / All Off Commands Program Temperature CommandsProgram Control Conditions Program Message CommandsEdit Program Condition PageProgram Time Clock Conditions Program Security Mode ConditionsProgram Zone Conditions Program Other ConditionsSELECT CONDITION NEVER PageRemote Commands Set Up DialTelephone Access Answer Outside CallDial Order Dial Out NumberDial Out Numbers PageExit Delay Set Up ArmingEntry Delay Audible Exit DelayEnable Auto Bypass Set up MiscellaneousEnable Quick Arm All On For AlarmHouse Codes 1-4Format Enable Freeze AlarmFlash For Alarm FORMATHouse Codes 1-4All On Time ClocksPage Daylight Savings Latitude, Longitude, and Time ZoneZONE NAME PageNUMBER Controller IP AddressController Port Number DESCRIPTIONSet Up Names Encryption KeyPage SET UP VOICE 1=CTRL 2=ZONE 3=BTTN ↓ Set Up VoiceSet Up Address 4=CODE 5=TEMP 6=AREA 8=MSG↑UNDERWRITERS LABORATORIES REQUIREMENTS FIRE ESCAPE PLANNINGPage FEDERAL COMMUNICATION COMMISSION NOTICE PageCANADIAN INDUSTRY CANADA NOTICE IF YOU HAVE TROUBLE WITH YOUR PHONESPage APPENDIX A - DIAL OUT PLANNER Omni IIe Voice Dial-OutPlannerPage INSTRUCTIONS TO CALLED PARTY PageCODE CHAR APPENDIX B - TEXT DESCRIPTION CHARACTER CODESCODE CHAR CODE CHARDESCRIPTION APPENDIX C - VOICE DESCRIPTION CODESCODE CODECODE CODEDESCRIPTION DESCRIPTIONCODE CODEDESCRIPTION DESCRIPTIONCODE DESCRIPTION CODE DESCRIPTIONCODE DESCRIPTION PagePage NOTE TO INSTALLER HAI New Orleans, LA U S A