Home Automation INC. Omni IIe, HOME AUTOMATION owner manual Messages, Show Message, Page

Page 47

To view your event log, from the top-level display or from the main menu, press the 7 key, then enter your code. The arrow keys may be used to scroll through the event log, starting with the most recent event.

Each event log entry displays the time and date on the top line and a description of the event on the bottom line:

7:15

PM

5/8

USER

NAME

AWAY

For trouble conditions, the event log will show the zone name or specific trouble condition and "TROUBLE":

10:59 AM 5/8

BATTERYTROUBLE

For trouble restorations, the event log will show the zone name or specific trouble condition and "TRBL RST":

11:57 AM

5/8

BATTERY

TRBL RST

The system records each remote access. A remote phone access is when someone calls into the system from an outside phone line. Remote phone access is also recorded if the system phones out in response to an alarm and the called party enters a code. The event log displays the code used to access the system and "REM ACCESS":

12:05 PM

5/8

USER NAME

REM ACCESS

An event is logged after three unsuccessful attempts are made to log into the system from a remote phone, the Omni IIe will lock out remote telephone access for 1 hour to discourage any further attempts to access the system - See Telephone Control.

Local access of the system using an in-house telephone is not recorded.

The event log will also record each time the PC Access software is used to access the system. The event log displays the code used to access the system and "PC ACCESS".

Messages

The Message menu is used to show, log, clear, and send text messages, and to say and phone (dial out) your voice messages.

To enter the Message menu, from the top-level display or from the main menu, press the 8 (MESSAGE) key on the console.

MESSAGE

1=SHOW 2=LOG 3=CLEAR

4=SAY 5=PHONE 6=SEND

Show Message

The 1 (SHOW) key allows you to display the selected text message(s) on the console's top-level display. This can be a helpful reminder of special events and occasions.

TRASH

NIGHT

ENTER

MESSAGE

Page 39

Image 47
Contents Document Number 20R00-50Rev. January HOME AUTOMATION, INCAll Rights Reserved Copyright 2001-2006Home Automation, IncContents INTRODUCTIONOVERALL DESCRIPTION SECURITY SYSTEM OPERATIONCONTROL TELEPHONE CONTROL PC AccessSETUP APPENDIX A - DIAL OUT PLANNER UNDERWRITERS LABORATORIES REQUIREMENTSFEDERAL COMMUNICATION COMMISSION NOTICE CANADIAN INDUSTRY CANADA NOTICEPage Page INTRODUCTIONUnderwriters Laboratories UL Listing 2- DAY OVERALL DESCRIPTIONConsole Operation 1- OFF7- CONSOLE LED Normal Top-LevelDisplayDisplay Menus 6- UP ARROWTo silence the beeper, press the * key Error BeepsMain Menu Trouble BeepsConfirmation Beep Omni IIe MaintenanceCancel Areas1 = DAY SECURITY SYSTEM OPERATIONArming the Security System 0 = OFF4 = VACATION Using Shortcut Keys2 = NIGHT 3 = AWAYRestoring Zones 9 = RESTOREQuick Arm Bypassing Zones#=GOTO What To Do When You Come HomeWhat Happens When the Alarm is Activated Burglar Alarm ActivatedPage Fire Alarm ActivatedGas Alarm Activated Emergency KeysPolice Emergency Duress Code Entered or Duress Alarm ActivatedAlarm Reset Alarm CancelPage Trouble IndicationsCodes Master CodeManager Code Panic SwitchesDuress Code Area ArmingPage GOTO AreaPage Testing Your SystemPage Control CommandsCONTROL About UPBAbout Rooms When set to UPB, the Omni IIe controller canRoom Controller LED Indicators HAI Lighting Control HLC FormatPage About Lutron RadioRAAbout House Controllers About CentraLiteHouse Codes When set to RadioRA, the Omni IIe controller canAbout ALC AboutOmni IIe Unit Numbers Unit NumbersScrolling Through Names Controlling UnitsControlling CentraLite Units Page Configuring Lighting Scenes in an HLC RoomStep OperationPage Controlling RadioRA UnitsControlling ALC or X-10Units Page Ramp Command ALCControlling Compose Units Internal Flags Timed CommandsScene Command Compose Status of a UnitWHEN ALL ON PHANTOM BUTTON 16 ON Controlling OutputsAll On / Off WHEN ALL ON LINK 50 ON WHEN ALL OFF LINK 50 OFFScene All Lights OnAll Off Leviton Scene ControlScene Off Command Scene CommandsScene Set Command Scene On CommandExecuting CentraLite Scenes Setting a Link Lighting ScenesActivating and Deactivating Links Executing Phantom ButtonsDinner for Two Button ButtonsTemperature Control Leave for Work ButtonPage HAI RC-SeriesThermostatsPage Programmable Energy Saver Modules PESMsPage The following control actions are allowed on PESMsPage Freeze AlarmsIMPORTANT NOTES Indoor and Outdoor TemperaturePage Temperature AlarmsHumidity Temperature Control of AppliancesPage Configuring HLC DevicesConfiguring HLC Devices using an Omni Console StatusStep Operation Setup Mode for HLC DevicesStep Operation Step OperationDEAD - DEAD PHONE LINE ONHK - ON HOOKOFFHK - OFF HOOK RING - RINGINGShow Events Page Event LogPage MessagesShow Message Phone Message Log MessageClear Message Say MessagePage MSGNAMEENTER MESSAGE Remote Phones TELEPHONE CONTROLTelephone Interface In-HousePhonesPage Phone Access Denied - Remote LockoutAlternate Method Main Menu4 - All 1 - Control2 - Security 3 - Button7 - Events When an HAI Communicating Thermostat is enteredWhen a Programmable Energy Saver PESM is entered 6 - StatusPanic Button over the Phone # # # # # # When the HAI Two-WayAudio Module is being used8 - Phone 9 - Good-ByeHow the Omni IIe Voice Dialer Works Emergency Dial-OutDigital Dialer Voice DialerPage What the Omni IIe Voice Dialer DoesWhat You Hear - If Your Omni IIe Calls You Entering the CodeOmni IIe Ethernet Connections PC AccessConnecting to Network via PC Access Built-InEthernet PortController Local NetworkDynamic DNS 192.168.0.101 Hub or HAI Omni IIeRouterPage Local / Wide Area Networki.e i.eAuthority Level SETUPSet Up Codes Access AreasPage Set Up TimeDuress Code TIMEPage Advanced Control Programming ACP1 = Add Programs 2 = Show ProgramsPage MenuPage Edit Programs3 = Delete All Programs Page Edit Programs WhenTimes Programs Page Control Unit / Switch Press Event ButtonsButton and Event Programs UPB 6-ButtonKeypad Corresponding Switch TableSwitch Omni IIePage Zone Event ButtonsAll On/Off Event Buttons Page Alarm Event ButtonsUPB Link Event Buttons X-10Event ButtonsPage Miscellaneous Event ButtonsMessage Event Buttons Pro-Link Page Edit Program CommandSwitch Press Event Buttons CentraLite Program Control CommandsWHEN LINK 1 ON Porch Light STATUS Unit Toggle CommandProgram Security Commands WHEN U1 SW UNIT 1 LED 3 ONProgram Temperature Commands Program Button CommandsProgram All On / All Off Commands Program Video CommandsPage Program Message CommandsEdit Program Condition Program Control ConditionsProgram Other Conditions Program Security Mode ConditionsProgram Zone Conditions Program Time Clock ConditionsPage SELECT CONDITION NEVERAnswer Outside Call Set Up DialTelephone Access Remote CommandsPage Dial Out NumberDial Out Numbers Dial OrderAudible Exit Delay Set Up ArmingEntry Delay Exit DelayAll On For Alarm Set up MiscellaneousEnable Quick Arm Enable Auto BypassFORMAT Enable Freeze AlarmFlash For Alarm House Codes 1-4FormatPage House Codes 1-4All OnTime Clocks Page Latitude, Longitude, and Time ZoneZONE NAME Daylight SavingsDESCRIPTION Controller IP AddressController Port Number NUMBERPage Set Up NamesEncryption Key 4=CODE 5=TEMP 6=AREA 8=MSG↑ Set Up VoiceSet Up Address SET UP VOICE 1=CTRL 2=ZONE 3=BTTN ↓Page UNDERWRITERS LABORATORIES REQUIREMENTSFIRE ESCAPE PLANNING Page FEDERAL COMMUNICATION COMMISSION NOTICEPage CANADIAN INDUSTRY CANADA NOTICEIF YOU HAVE TROUBLE WITH YOUR PHONES Page APPENDIX A - DIAL OUT PLANNEROmni IIe Voice Dial-OutPlanner Page INSTRUCTIONS TO CALLED PARTYCODE CHAR APPENDIX B - TEXT DESCRIPTION CHARACTER CODESCODE CHAR CODE CHARCODE APPENDIX C - VOICE DESCRIPTION CODESCODE DESCRIPTIONDESCRIPTION CODEDESCRIPTION CODEDESCRIPTION CODEDESCRIPTION CODEPage CODE DESCRIPTIONCODE DESCRIPTION CODE DESCRIPTIONPage HAI New Orleans, LA U S A NOTE TO INSTALLER