Home Automation HOME AUTOMATION, INC. Omni IIe Main Menu, Error Beeps, Trouble Beeps, Page

Page 12

When using the arrow keys to scroll through lists of areas, buttons, codes, temperature zones, units, or zones, only the named items are displayed. If no text description has been given to an item, it will be skipped over when scrolling through that list. You can still enter any item number to access it directly, and then scroll up and down among the named items. To look at another specific item, simply enter the item number followed by the Down Arrow key.

In some cases, the keypad keys (0-9, *, #) are assigned to different functions or menus. A key assignment is indicated by the character key directly in front of the new function on the bottom line of the display. For example, if the bottom line says, "2=DELETE", you may press the 2 key to delete. From the top-level display, each key functions as a menu choice. Simply press the appropriate key and you will enter that menu.

Main Menu

The main menu is entered from the top-level display by pressing the ' # ' key. This menu displays all of the functions that you can perform from the console. It is not necessary to display the main menu before selecting a function if the number for the desired menu item is known. The following menu choices are available:

1=CONTROL 2=SECURITY

3=BUTTON 4=ALL

5=TEMP 6=STATUS 7=EVENTS 8=MESSAGE

9=SETUP

Menu 1 - Selects Control functions for controlling lights and appliances.

Menu 2 - Selects Security functions (arming, disarming, bypassing, and restoring).

Menu 3 - Allows a Button (macro) to be activated.

Menu 4 - Selects All Lights On / All Units Off commands and Leviton Scene Control commands.

Menu 5 - Allows Temperature control for Thermostats and Energy Saver Modules.

Menu 6 - Allows various status items to be displayed.

Menu 7 - Allows you to view an event log of security "happenings".

Menu 8 - Allows you to show, log, clear, say, phone, or send a message.

Menu 9 - Allows you to enter setup mode for different operating configurations.

Error Beeps

If you press a key that is invalid for the function that you are doing, the console will beep 3 times, indicating that it is not a valid option. Look at the bottom line of the display to see what keys you can press next.

Trouble Beeps

The Omni IIe constantly checks the entire system for proper operation. If trouble is found, the trouble is displayed on the bottom line and the console will beep at the rate of two beeps per second to alert you to the trouble. This feature can be turned off if desired - See Set Up Arming, Beep On Trouble.

To silence the beeper, press the ' * ' key.

For more information, see Trouble Indications.

Page 4

Image 12
Contents HOME AUTOMATION, INC Document Number 20R00-50Rev. JanuaryCopyright 2001-2006Home Automation, Inc All Rights ReservedINTRODUCTION OVERALL DESCRIPTIONSECURITY SYSTEM OPERATION ContentsCONTROL PC Access TELEPHONE CONTROLSETUP UNDERWRITERS LABORATORIES REQUIREMENTS FEDERAL COMMUNICATION COMMISSION NOTICECANADIAN INDUSTRY CANADA NOTICE APPENDIX A - DIAL OUT PLANNERPage INTRODUCTION Underwriters Laboratories UL ListingPage OVERALL DESCRIPTION Console Operation1- OFF 2- DAYNormal Top-LevelDisplay Display Menus6- UP ARROW 7- CONSOLE LEDError Beeps Main MenuTrouble Beeps To silence the beeper, press the * keyOmni IIe Maintenance CancelAreas Confirmation BeepSECURITY SYSTEM OPERATION Arming the Security System0 = OFF 1 = DAYUsing Shortcut Keys 2 = NIGHT3 = AWAY 4 = VACATION9 = RESTORE Quick ArmBypassing Zones Restoring ZonesWhat To Do When You Come Home What Happens When the Alarm is ActivatedBurglar Alarm Activated #=GOTOFire Alarm Activated Gas Alarm ActivatedEmergency Keys PageDuress Code Entered or Duress Alarm Activated Alarm ResetAlarm Cancel Police EmergencyTrouble Indications CodesMaster Code PagePanic Switches Duress CodeArea Arming Manager CodeGOTO Area PageTesting Your System PageControl Commands CONTROLAbout UPB PageWhen set to UPB, the Omni IIe controller can Room Controller LED IndicatorsHAI Lighting Control HLC Format About RoomsAbout Lutron RadioRA About House ControllersAbout CentraLite PageWhen set to RadioRA, the Omni IIe controller can About ALCAbout House CodesUnit Numbers Scrolling Through NamesControlling Units Omni IIe Unit NumbersConfiguring Lighting Scenes in an HLC Room StepOperation Controlling CentraLite Units PageControlling RadioRA Units Controlling ALC or X-10UnitsPage Ramp Command ALC Controlling Compose UnitsPage Timed Commands Scene Command ComposeStatus of a Unit Internal FlagsControlling Outputs All On / OffWHEN ALL ON LINK 50 ON WHEN ALL OFF LINK 50 OFF WHEN ALL ON PHANTOM BUTTON 16 ONAll Lights On All OffLeviton Scene Control SceneScene Commands Scene Set CommandScene On Command Scene Off CommandSetting a Link Lighting Scenes Activating and Deactivating LinksExecuting Phantom Buttons Executing CentraLite ScenesButtons Temperature ControlLeave for Work Button Dinner for Two ButtonHAI RC-SeriesThermostats PageProgrammable Energy Saver Modules PESMs PageThe following control actions are allowed on PESMs PageFreeze Alarms IMPORTANT NOTESIndoor and Outdoor Temperature PageTemperature Alarms HumidityTemperature Control of Appliances PageConfiguring HLC Devices Configuring HLC Devices using an Omni ConsoleStatus PageSetup Mode for HLC Devices Step OperationStep Operation Step OperationONHK - ON HOOK OFFHK - OFF HOOKRING - RINGING DEAD - DEAD PHONE LINEEvent Log Show Events PageMessages Show MessagePage Log Message Clear MessageSay Message Phone MessageMSGNAME ENTER MESSAGEPage TELEPHONE CONTROL Telephone InterfaceIn-HousePhones Remote PhonesPhone Access Denied - Remote Lockout Alternate MethodMain Menu Page1 - Control 2 - Security3 - Button 4 - AllWhen an HAI Communicating Thermostat is entered When a Programmable Energy Saver PESM is entered6 - Status 7 - EventsWhen the HAI Two-WayAudio Module is being used 8 - Phone9 - Good-Bye Panic Button over the Phone # # # # # #Emergency Dial-Out Digital DialerVoice Dialer How the Omni IIe Voice Dialer WorksWhat the Omni IIe Voice Dialer Does What You Hear - If Your Omni IIe Calls YouEntering the Code PagePC Access Connecting to Network via PC AccessBuilt-InEthernet Port Omni IIe Ethernet ConnectionsLocal Network Dynamic DNS192.168.0.101 Hub or HAI Omni IIeRouter ControllerLocal / Wide Area Network i.ei.e PageSETUP Set Up CodesAccess Areas Authority LevelSet Up Time Duress CodeTIME PageAdvanced Control Programming ACP 1 = Add Programs2 = Show Programs PageMenu PageEdit Programs 3 = Delete All ProgramsPage Edit Programs When Times ProgramsPage Control Unit / Switch Press Event Buttons Button and Event ProgramsPage Corresponding Switch Table SwitchOmni IIe UPB 6-ButtonKeypadZone Event Buttons All On/Off Event ButtonsPage Alarm Event Buttons UPB Link Event ButtonsX-10Event Buttons PageMiscellaneous Event Buttons Message Event Buttons Pro-LinkPage Edit Program Command Switch Press Event Buttons CentraLiteProgram Control Commands PageUnit Toggle Command Program Security CommandsWHEN U1 SW UNIT 1 LED 3 ON WHEN LINK 1 ON Porch Light STATUSProgram Button Commands Program All On / All Off CommandsProgram Video Commands Program Temperature CommandsProgram Message Commands Edit Program ConditionProgram Control Conditions PageProgram Security Mode Conditions Program Zone ConditionsProgram Time Clock Conditions Program Other ConditionsSELECT CONDITION NEVER PageSet Up Dial Telephone AccessRemote Commands Answer Outside CallDial Out Number Dial Out NumbersDial Order PageSet Up Arming Entry DelayExit Delay Audible Exit DelaySet up Miscellaneous Enable Quick ArmEnable Auto Bypass All On For AlarmEnable Freeze Alarm Flash For AlarmHouse Codes 1-4Format FORMATHouse Codes 1-4All On Time ClocksPage Latitude, Longitude, and Time Zone ZONE NAMEDaylight Savings PageController IP Address Controller Port NumberNUMBER DESCRIPTIONSet Up Names Encryption KeyPage Set Up Voice Set Up AddressSET UP VOICE 1=CTRL 2=ZONE 3=BTTN ↓ 4=CODE 5=TEMP 6=AREA 8=MSG↑UNDERWRITERS LABORATORIES REQUIREMENTS FIRE ESCAPE PLANNINGPage FEDERAL COMMUNICATION COMMISSION NOTICE PageCANADIAN INDUSTRY CANADA NOTICE IF YOU HAVE TROUBLE WITH YOUR PHONESPage APPENDIX A - DIAL OUT PLANNER Omni IIe Voice Dial-OutPlannerPage INSTRUCTIONS TO CALLED PARTY PageAPPENDIX B - TEXT DESCRIPTION CHARACTER CODES CODE CHARCODE CHAR CODE CHARAPPENDIX C - VOICE DESCRIPTION CODES CODEDESCRIPTION CODECODE DESCRIPTIONCODE DESCRIPTIONCODE DESCRIPTIONCODE DESCRIPTIONCODE DESCRIPTION CODE DESCRIPTIONCODE DESCRIPTION PagePage NOTE TO INSTALLER HAI New Orleans, LA U S A