TELEPHONE CONNECTIONS

1.If an RJ31X jack has been supplied by the telephone company, it is probably wired correctly and the controller can be connected by plugging the supplied 8 conductor telephone cable into the RJ31X jack. The other end of the cable is spaded. The green, red, brown, and gray wires must be connected to the controller at the designated terminals under the section of the board marked 'PHONE'.

2.If required, install the supplied RJ31X jack as shown in the following diagram. The polarity must be correct for proper operation of the phone access feature.

3.IT IS IMPERATIVE THAT THE PHONE LINE COMING INTO THE HOUSE BE CONNECTED TO A GROUNDED SURGE ARRESTOR OUTSIDE THE PREMISES. IT IS THE RESPONSIBILITY OF THE TELEPHONE COMPANY TO PROVIDE THIS SURGE ARRESTOR.

4.INSPECT THE INCOMING PHONE LINES. THE FIRST THING THAT THEY SHOULD GO TO IS A SMALL BOX ON THE OUTSIDE OF THE PREMISES. THERE SHOULD BE A HEAVY GROUND WIRE COMING FROM THIS BOX GOING TO A COLD WATER PIPE OR A SEPARATE GROUNDING ROD.

5.IF THERE IS NO SURGE ARRESTOR OR IF THE GROUND WIRE IS MISSING, HAVE THE CUSTOMER INSIST THAT THE TELEPHONE COMPANY INSTALL ONE FOR THE SAFETY OF THE CUSTOMER.

6.WHEN WIRING A RJ31X JACK, MAKE SURE THAT THE INCOMING PHONE LINES GO TO THE TELEPHONE COMPANY SURGE ARRESTOR BEFORE THEY GO TO THE RJ31X JACK.

7.When the RJ31X is installed as shown, locate the green, red, brown, and gray spaded wires from the 8 conductor phone cable and connect to the section on the Omni II controller marked 'PHONE'. Plug the modular end of the cable into the RJ31X jack. If necessary, bend the tab up on the plug to ensure a tight fit that will not fall out.

8.Verify the following if you have trouble during check out: With the system running, the RJ31X jack properly connected and all phones on-hook (hung up), the PHONE LED, located in the upper left corner of the controller, should be OFF. If it is on, reverse the RED and GREEN wires to both the house phones and the telephone company wires at the RJ31X jack. When the receiver is picked up on any phone, the PHONE LED will come on. When the phone line rings, the PHONE LED will light.

9.If the Omni II is accessed on an in house telephone, the Omni II will disconnect the phones from the phone company lines and supply its own talk voltage to the phones. The PHONE LED will be on in this case.

10.Refer to FIGURE 5 (RJ31X JACK CONNECTIONS) for this configuration.

Page 9

Image 15
Contents Installation Manual Page Home Automation, Inc Installation Manual Contents Installer Setup Figures Planning IntroductionController Hookup InstallationController Hookup About Security Zones Overall Connections Diagram About Fire Zones TWO-WIRE Fire Zone Connections FOUR-WIRE Fire Zone Connections Telephone Connections Refer to RJ31X Jack Connections for this configurationRJ31X Jack Connections LCD Console Hookup Console SetupConsole Self Test Console Connections Sounder Outputs Sounder Connections Reset Outputs Controller OutputsOutput Applications Home Control Modules Remote ARM/DISARM SwitchRemote Keyswitch Connections HAI Thermostats HAI Thermostat ConnectionsConnections Programmable Energy Saver ModulesTEMPERATURE, Outdoor TEMPERATURE, and Humidity Temperature / Humidity Sensor ConnectionsPesm Connections BUILT-IN Serial Port RS-232 Connections System Power UP Procedure Console Check OUTTelephone Check OUT Burglar Zone Check OUT Fire Zone Check OUTHome Control Checkout Case of Trouble Customer CheckoutFollow this procedure for removing the controller board Digital Communicator Description of Contact IDDescription of 4/2 Format Opening and Closing Reports FormatInstaller Setup Setup ControlHouse Code Output Type Number Description Output TypesSetup Zones Wireless ReceiverZone Resistors Zone Type Number Description Zone TypesType Through Z 48 Type Zone Response TimeLatching Zone Types Description of Zone TypesENTRY/EXIT Fire Emergency Police EmergencyDuress Emergency Silent Dial OUT Supervised FireTemperature Alarm Keyswitch InputOutdoor Temperature TemperatureCommunicator Type Setup Digital CommunicatorFirst Phone NUMBER, First Account Number Second Phone NUMBER, Second Account NumberAutomatic Test Time Report OPEN/CLOSESetup Areas Control Setup AreasSetup Areas Buttons Setup Areas ZonesSetup Areas Consoles Setup Areas MessagesSET-UP Areas Thermostats Setup Temperatures Temperature DisplayThermostat Type PC Access Code Setup MiscellaneousInstaller Code Enable PC AccessFire Alarm Verification Outside Siren DelayDial OUT Delay Alarm Reset TimeTime Display Enable Emergency KeysSupervise INT Sndr Supervise EXT SndrDead Line Detect AC Power FrequencyClock Adjustment Date DisplayReset System Eeprom Reset System RAMModel and Software Version Setup Expansion Serial 1 Function Function Types Number DescriptionSerial 2 Rate VDC Omni II SpecificationsUnderwriters Laboratories UL Installation Requirements Maximum current ratings for 24-hours Hour Standby Battery CapacitySmoke Detector Installation Guidelines Zone Type Trip Trouble Description Appendix a Contact ID Reporting FormatInformation for Central Station Appendix B Digital Communicator Code SheetCode Zone Description Action to Take Code Zone Description Action to Take Code Zone Description Action to Take Code Zone Description Action to Take Page HAI New Orleans, LA U S a