FIRE TAMPER

This zone type is used to monitor the wiring to bells and sirens (other than those connected to the Horn Output). The zone will report trouble if an open, short, or other wiring problem is detected in the supervised bell circuit. This zone will make a digital dial out when violated. Connect a wire from the Fire Tamper zone (+) to an output configured as a Sounder.

AUXILIARY

A zone defined as AUXILIARY is ignored for security. It is used to activate macros or to conditionalize programs. This is the default setting for all zones. Zones that are not in use should be configured as AUXILIARY.

KEYSWITCH INPUT

This zone is used to arm AWAY and Disarm the Omni II security system using a toggle (to ground) keyswitch or keypad.

PROGRAMMABLE ENERGY SAVER MODULE

This zone type is for use with the Programmable Energy Saver Modules (PESM). It converts the Zone and the corresponding Output to operate the PESM. Only Zones 9-16 can be programmed as a PESM.

OUTDOOR TEMPERATURE

Use this zone type for Outdoor Temperature Sensors. The outdoor temperature can be displayed on the console, spoken over the telephone, or displayed on an HAI Communicating Thermostat.

TEMPERATURE

The general-purpose TEMPERATURE ZONE type is typically used to monitor indoor temperatures and control devices. It sets the zone secure/not ready for program conditionals and event button activation.

If FREEZE ALARM is enabled, it reports a potential freeze condition if the temperature falls below 40o.

TEMPERATURE ALARM

The TEMPERATURE ALARM ZONE type will generate an alarm (console beeper, no sirens) and dial out if the temperature goes above the high setpoint or drops below the low setpoint.

HUMIDITY

The HUMIDITY ZONE type is used to monitor indoor and outdoor humidity levels from 0 to 100 percent using the Model 31A00-2 Indoor/Outdoor Temperature and Humidity Sensor. It sets the zone secure/not ready state for program conditionals and event button activation programs.

NOTE ON TEMPERATURE AND HUMIDITY ZONE TYPES

Outdoor temperature, temperature, and temperature alarm zone types all have HEAT (LOW) and COOL (HIGH) setpoints. The zone is "Not Ready" when the temperature is above the high setpoint or below the low setpoint. The zone is "Secure" when the temperature is between the setpoints. Setting a setpoint to 0 disables the setpoint.

Except for a type 83, the alarm is not activated. The zone "Not Ready" or "Secure" status is used to activate button programs and program conditionals.

Page 37

Image 43
Contents Installation Manual Page Home Automation, Inc Installation Manual Contents Installer Setup Figures Planning IntroductionController Hookup InstallationController Hookup About Security Zones Overall Connections Diagram About Fire Zones TWO-WIRE Fire Zone Connections FOUR-WIRE Fire Zone Connections Telephone Connections Refer to RJ31X Jack Connections for this configurationRJ31X Jack Connections LCD Console Hookup Console SetupConsole Self Test Console Connections Sounder Outputs Sounder Connections Controller Outputs Reset OutputsOutput Applications Home Control Modules Remote ARM/DISARM SwitchRemote Keyswitch Connections HAI Thermostats HAI Thermostat ConnectionsConnections Programmable Energy Saver ModulesTEMPERATURE, Outdoor TEMPERATURE, and Humidity Temperature / Humidity Sensor ConnectionsPesm Connections BUILT-IN Serial Port RS-232 Connections Console Check OUT System Power UP ProcedureTelephone Check OUT Fire Zone Check OUT Burglar Zone Check OUTHome Control Checkout Case of Trouble Customer CheckoutFollow this procedure for removing the controller board Description of Contact ID Digital CommunicatorDescription of 4/2 Format Opening and Closing Reports FormatSetup Control Installer SetupHouse Code Output Type Number Description Output TypesWireless Receiver Setup ZonesZone Resistors Zone Type Number Description Zone TypesType Through Z 48 Type Zone Response TimeDescription of Zone Types Latching Zone TypesENTRY/EXIT Fire Emergency Police EmergencyDuress Emergency Silent Dial OUT Supervised FireTemperature Alarm Keyswitch InputOutdoor Temperature TemperatureCommunicator Type Setup Digital CommunicatorFirst Phone NUMBER, First Account Number Second Phone NUMBER, Second Account NumberAutomatic Test Time Report OPEN/CLOSESetup Areas Control Setup AreasSetup Areas Buttons Setup Areas ZonesSetup Areas Messages Setup Areas ConsolesSET-UP Areas Thermostats Temperature Display Setup TemperaturesThermostat Type PC Access Code Setup MiscellaneousInstaller Code Enable PC AccessFire Alarm Verification Outside Siren DelayDial OUT Delay Alarm Reset TimeTime Display Enable Emergency KeysSupervise INT Sndr Supervise EXT SndrDead Line Detect AC Power FrequencyClock Adjustment Date DisplayReset System RAM Reset System EepromModel and Software Version Setup Expansion Function Types Number Description Serial 1 FunctionSerial 2 Rate VDC Omni II SpecificationsUnderwriters Laboratories UL Installation Requirements Maximum current ratings for 24-hours Hour Standby Battery CapacitySmoke Detector Installation Guidelines Zone Type Trip Trouble Description Appendix a Contact ID Reporting FormatInformation for Central Station Appendix B Digital Communicator Code SheetCode Zone Description Action to Take Code Zone Description Action to Take Code Zone Description Action to Take Code Zone Description Action to Take Page HAI New Orleans, LA U S a