Home Automation 20A00-1 installation manual Remote Keyswitch Connections

Page 24

1KEOLRESISTOR

BLACK RED

YELLOW GREEN

YELLOW

GREEN

RED GREEN

+ +

-

BLACK

RED

MOMENTARY CONTACT

KEYSWITCH

FIGURE 9 - REMOTE KEYSWITCH CONNECTIONS

Page 18

Image 24
Contents Installation Manual Page Home Automation, Inc Installation Manual Contents Installer Setup Figures Introduction PlanningInstallation Controller HookupController Hookup About Security Zones Overall Connections Diagram About Fire Zones TWO-WIRE Fire Zone Connections FOUR-WIRE Fire Zone Connections Refer to RJ31X Jack Connections for this configuration Telephone ConnectionsRJ31X Jack Connections Console Setup LCD Console HookupConsole Self Test Console Connections Sounder Outputs Sounder Connections Reset Outputs Controller OutputsOutput Applications Remote ARM/DISARM Switch Home Control ModulesRemote Keyswitch Connections HAI Thermostat Connections HAI ThermostatsProgrammable Energy Saver Modules ConnectionsTemperature / Humidity Sensor Connections TEMPERATURE, Outdoor TEMPERATURE, and HumidityPesm Connections BUILT-IN Serial Port RS-232 Connections System Power UP Procedure Console Check OUTTelephone Check OUT Burglar Zone Check OUT Fire Zone Check OUTHome Control Checkout Customer Checkout Case of TroubleFollow this procedure for removing the controller board Digital Communicator Description of Contact IDDescription of 4/2 Format Format Opening and Closing ReportsInstaller Setup Setup ControlHouse Code Output Types Output Type Number DescriptionSetup Zones Wireless ReceiverZone Resistors Zone Types Type Through Z 48 TypeZone Response Time Zone Type Number DescriptionLatching Zone Types Description of Zone TypesENTRY/EXIT Police Emergency Duress Emergency Silent Dial OUTSupervised Fire Fire EmergencyKeyswitch Input Outdoor TemperatureTemperature Temperature AlarmSetup Digital Communicator First Phone NUMBER, First Account NumberSecond Phone NUMBER, Second Account Number Communicator TypeReport OPEN/CLOSE Automatic Test TimeSetup Areas Setup Areas ControlSetup Areas Zones Setup Areas ButtonsSetup Areas Consoles Setup Areas MessagesSET-UP Areas Thermostats Setup Temperatures Temperature DisplayThermostat Type Setup Miscellaneous Installer CodeEnable PC Access PC Access CodeOutside Siren Delay Dial OUT DelayAlarm Reset Time Fire Alarm VerificationEnable Emergency Keys Supervise INT SndrSupervise EXT Sndr Time DisplayAC Power Frequency Clock AdjustmentDate Display Dead Line DetectReset System Eeprom Reset System RAMModel and Software Version Setup Expansion Serial 1 Function Function Types Number DescriptionSerial 2 Rate Omni II Specifications VDCUnderwriters Laboratories UL Installation Requirements Hour Standby Battery Capacity Maximum current ratings for 24-hoursSmoke Detector Installation Guidelines Appendix a Contact ID Reporting Format Zone Type Trip Trouble DescriptionAppendix B Digital Communicator Code Sheet Information for Central StationCode Zone Description Action to Take Code Zone Description Action to Take Code Zone Description Action to Take Code Zone Description Action to Take Page HAI New Orleans, LA U S a