Home Automation 20A00-1 installation manual Introduction, Planning

Page 7

INTRODUCTION

This installation guide is intended as an aid to installing the Omni II Control & Security System. The installer should also have thoroughly reviewed and understood the Omni II Owner's Manual, which has important information regarding final setup of the system. This manual assumes that the installer has a basic understanding of installing a security system.

This guide applies to the 20A00-1, -4, and -12 versions of the Omni II series controller. Refer to the Underwriters Laboratories Installation Requirements section for details in the application of each. Failure to install the Omni II and its accessories in accordance with the UL Requirements in this manual and in the Owner's Manual, is a violation of the Listing Mark.

PLANNING

Before you start, your system should be planned as follows:

1.Zones:

Decide where each contact or detector will be located

Decide which zone it will occupy

Decide zone type for each zone

Decide what area will be assigned

With the customer, decide what text and voice descriptors will be used. Consult table of voice descriptors, so that you can choose similar words for the text to avoid customer confusion.

See SMOKE DETECTOR INSTALLATION GUIDELINES to plan locations for smoke detectors

2.Consoles:

Consult the customer on the console location. The console should be easily accessible.

3.Interior Sounder and Outside Siren:

Locate both where they cannot be tampered with.

4.Lighting and Appliance Switches and Modules.

5.Plan for thermostats, energy saver modules, or other options.

6.Give consideration to where the controller will go. Remember that it needs a duplex receptacle not controlled by a switch, preferably on its own circuit, within 5 feet of the controller.

Page 1

Image 7
Contents Installation Manual Page Home Automation, Inc Installation Manual Contents Installer Setup Figures Planning IntroductionController Hookup InstallationController Hookup About Security Zones Overall Connections Diagram About Fire Zones TWO-WIRE Fire Zone Connections FOUR-WIRE Fire Zone Connections Telephone Connections Refer to RJ31X Jack Connections for this configurationRJ31X Jack Connections LCD Console Hookup Console SetupConsole Self Test Console Connections Sounder Outputs Sounder Connections Controller Outputs Reset OutputsOutput Applications Home Control Modules Remote ARM/DISARM SwitchRemote Keyswitch Connections HAI Thermostats HAI Thermostat ConnectionsConnections Programmable Energy Saver ModulesTEMPERATURE, Outdoor TEMPERATURE, and Humidity Temperature / Humidity Sensor ConnectionsPesm Connections BUILT-IN Serial Port RS-232 Connections Console Check OUT System Power UP ProcedureTelephone Check OUT Fire Zone Check OUT Burglar Zone Check OUTHome Control Checkout Case of Trouble Customer CheckoutFollow this procedure for removing the controller board Description of Contact ID Digital CommunicatorDescription of 4/2 Format Opening and Closing Reports FormatSetup Control Installer SetupHouse Code Output Type Number Description Output TypesWireless Receiver Setup ZonesZone Resistors Zone Type Number Description Zone TypesType Through Z 48 Type Zone Response TimeDescription of Zone Types Latching Zone TypesENTRY/EXIT Fire Emergency Police EmergencyDuress Emergency Silent Dial OUT Supervised FireTemperature Alarm Keyswitch InputOutdoor Temperature TemperatureCommunicator Type Setup Digital CommunicatorFirst Phone NUMBER, First Account Number Second Phone NUMBER, Second Account NumberAutomatic Test Time Report OPEN/CLOSESetup Areas Control Setup AreasSetup Areas Buttons Setup Areas ZonesSetup Areas Messages Setup Areas ConsolesSET-UP Areas Thermostats Temperature Display Setup TemperaturesThermostat Type PC Access Code Setup MiscellaneousInstaller Code Enable PC AccessFire Alarm Verification Outside Siren DelayDial OUT Delay Alarm Reset TimeTime Display Enable Emergency KeysSupervise INT Sndr Supervise EXT SndrDead Line Detect AC Power FrequencyClock Adjustment Date DisplayReset System RAM Reset System EepromModel and Software Version Setup Expansion Function Types Number Description Serial 1 FunctionSerial 2 Rate VDC Omni II SpecificationsUnderwriters Laboratories UL Installation Requirements Maximum current ratings for 24-hours Hour Standby Battery CapacitySmoke Detector Installation Guidelines Zone Type Trip Trouble Description Appendix a Contact ID Reporting FormatInformation for Central Station Appendix B Digital Communicator Code SheetCode Zone Description Action to Take Code Zone Description Action to Take Code Zone Description Action to Take Code Zone Description Action to Take Page HAI New Orleans, LA U S a