Z 1 TYPE THROUGH Z 48 TYPE
This item specifies the zone type for each zone. All choices are listed in this manual under DESCRIPTION OF ZONE TYPES.
For zone types, the current setting is shown on the bottom line.
ZONE 1 TYPE: |
| 64 |
AUXILIARY | #=CHNG | ↕ |
THROUGH |
|
|
ZONE 48 TYPE: |
| 64 |
AUXILIARY | #=CHNG | ↑ |
To change a zone type, press the ' # ' key, then use the arrow keys to scroll through the list of zone types. Press the ' # ' key to select a new type. The display shows:
SELECT TYPE: | 1 |
PERIMETER | ↕ |
ZONE RESPONSE TIME
All zones, in the Omni II are set to a 300 millisecond fixed response time.
ZONE TYPES
ZONE TYPE | NUMBER | DESCRIPTION |
ENTRY/EXIT | 0 | Entry/Exit |
PERIMETER | 1 | Perimeter |
NIGHT INT | 2 | Night Interior |
AWAY INT | 3 | Away Interior |
2X ENTRY DELAY | 4 | Double Entry Delay |
4X ENTRY DELAY | 5 | Quadruple Entry Delay |
LATCH PERIM | 6 | Latching Perimeter |
LATCH NIGHT INT | 7 | Latching Night Interior |
LATCH AWAY INT | 8 | Latching Away Interior |
PANIC | 16 | Panic |
POLICE EMERG | 17 | Police Emergency |
SILENT DURESS | 18 | Duress |
TAMPER | 19 | Tamper |
LATCH TAMPER | 20 | Latching Tamper |
FIRE | 32 | Fire |
FIRE EMERG | 33 | Fire Emergency |
GAS | 34 | Gas Alarm |
AUX EMERG | 48 | Auxiliary Emergency |
TROUBLE | 49 | Trouble |
FREEZE | 54 | Freeze |
WATER | 55 | Water |
FIRE TAMPER | 56 | Fire Tamper |
AUXILIARY | 64 | Auxiliary |
KEY SWITCH | 65 | Keyswitch Input |
ENERGY SAVER | 80 | Programmable Energy Saver Module |
OUTDOOR TMP | 81 | Outdoor Temperature |
TEMPERATURE | 82 | Temperature |
TEMP ALARM | 83 | Temperature Alarm |
HUMIDITY | 84 | Humidity |
Page 34