Home Automation 20A00-1 installation manual Figures

Page 6

OMNI II SPECIFICATIONS

51

UNDERWRITER'S LABORATORIES (UL) INSTALLATION REQUIREMENTS

52

24-HOUR STANDBY BATTERY CAPACITY

53

SMOKE DETECTOR INSTALLATION GUIDELINES

54

APPENDIX A – CONTACT ID REPORTING FORMAT

55

APPENDIX B - DIGITAL COMMUNICATOR CODE SHEET

56

FIGURES

 

FIGURE 1 - CONTROLLER HOOKUP

3

FIGURE 2 - OVERALL CONNECTIONS DIAGRAM

5

FIGURE 3 - TWO-WIRE FIRE ZONE CONNECTIONS

7

FIGURE 4 - FOUR-WIRE FIRE ZONE CONNECTIONS

8

FIGURE 5 - RJ31X JACK CONNECTIONS

10

FIGURE 6 - CONSOLE CONNECTIONS

13

FIGURE 7 - SOUNDER CONNECTIONS

15

FIGURE 8 - RESETTING CONTROLLER OUTPUTS

16

FIGURE 9 - REMOTE KEYSWITCH CONNECTIONS

18

FIGURE 10 - HAI THERMOSTAT CONNECTIONS

19

FIGURE 11 - TEMPERATURE / HUMIDITY SENSOR CONNECTIONS

21

FIGURE 12 - PESM CONNECTIONS

22

FIGURE 13 - RS-232 CONNECTIONS

24

FIGURE 14 - RS-485 CONNECTIONS

24

FIGURE 15 - 24-HOUR STANDBY CONNECTIONS

53

Image 6
Contents Installation Manual Page Home Automation, Inc Installation Manual Contents Installer Setup Figures Introduction PlanningInstallation Controller HookupController Hookup About Security Zones Overall Connections Diagram About Fire Zones TWO-WIRE Fire Zone Connections FOUR-WIRE Fire Zone Connections Refer to RJ31X Jack Connections for this configuration Telephone ConnectionsRJ31X Jack Connections Console Setup LCD Console HookupConsole Self Test Console Connections Sounder Outputs Sounder Connections Reset Outputs Controller OutputsOutput Applications Remote ARM/DISARM Switch Home Control ModulesRemote Keyswitch Connections HAI Thermostat Connections HAI ThermostatsProgrammable Energy Saver Modules ConnectionsTemperature / Humidity Sensor Connections TEMPERATURE, Outdoor TEMPERATURE, and HumidityPesm Connections BUILT-IN Serial Port RS-232 Connections System Power UP Procedure Console Check OUTTelephone Check OUT Burglar Zone Check OUT Fire Zone Check OUTHome Control Checkout Customer Checkout Case of TroubleFollow this procedure for removing the controller board Digital Communicator Description of Contact IDDescription of 4/2 Format Format Opening and Closing ReportsInstaller Setup Setup ControlHouse Code Output Types Output Type Number DescriptionSetup Zones Wireless ReceiverZone Resistors Zone Response Time Zone TypesType Through Z 48 Type Zone Type Number DescriptionLatching Zone Types Description of Zone TypesENTRY/EXIT Supervised Fire Police EmergencyDuress Emergency Silent Dial OUT Fire EmergencyTemperature Keyswitch InputOutdoor Temperature Temperature AlarmSecond Phone NUMBER, Second Account Number Setup Digital CommunicatorFirst Phone NUMBER, First Account Number Communicator TypeReport OPEN/CLOSE Automatic Test TimeSetup Areas Setup Areas ControlSetup Areas Zones Setup Areas ButtonsSetup Areas Consoles Setup Areas MessagesSET-UP Areas Thermostats Setup Temperatures Temperature DisplayThermostat Type Enable PC Access Setup MiscellaneousInstaller Code PC Access CodeAlarm Reset Time Outside Siren DelayDial OUT Delay Fire Alarm VerificationSupervise EXT Sndr Enable Emergency KeysSupervise INT Sndr Time DisplayDate Display AC Power FrequencyClock Adjustment Dead Line DetectReset System Eeprom Reset System RAMModel and Software Version Setup Expansion Serial 1 Function Function Types Number DescriptionSerial 2 Rate Omni II Specifications VDCUnderwriters Laboratories UL Installation Requirements Hour Standby Battery Capacity Maximum current ratings for 24-hoursSmoke Detector Installation Guidelines Appendix a Contact ID Reporting Format Zone Type Trip Trouble DescriptionAppendix B Digital Communicator Code Sheet Information for Central StationCode Zone Description Action to Take Code Zone Description Action to Take Code Zone Description Action to Take Code Zone Description Action to Take Page HAI New Orleans, LA U S a