Franke Consumer Products FQD 907 manual Mounting the hood body, Connections

Page 19

Mounting the hood body

• Open the ducting panels.

• Disconnect the panel from the hood canopy by slid- ing the fixing pin lever.(A)

• Remove the metal grease filters by turning the han- dles provided.

• Adjust the two screws Vr, on brackets 11a, to a mini- mum.(B)

• Hook the hood canopy onto the two brackets 11a.

• From inside the hood canopy, adjust the screws Vr to set the Hood Canopy level.

• Tighten the safety screw 11.

( A )

Vr

( B )

Connections

DUCTED VERSION AIR EXHAUST SYSTEM

When installing the ducted version, connect the hood to the chimney using either a flexible or rigid

pipe ø 150 mm, the choice of which is left to the in- staller.

• Fix the pipe in position using sufficient pipe clamps (not supplied).

• Remove any activated charcoal filters.

RECIRCULATION VERSION AIR OUTLET

8

 

To install the Recirculation Version of the hood, the

 

optional Activated charcoal cartridge kit must be pur-

16

chased.

 

Screw the filter cover onto the air outlet, using four screws 12c (2.9 x 12.5).

Fix the directional grille 8 on the recirculation air outlet using the 2 screws 12d (2,9 x 9,5) provided.

ø 150

12d

12c

EN

 

1

 

19

Image 19
Contents Istruzioni per l’uso e l’installazione Indice Index Sommaire Inhaltsverzeichnis Içerikler Manutenzione InstallazioneConsigli E Suggerimenti USOIngombro Componenti CaratteristicheForatura Parete e Fissaggio Staffe InstallazioneUscita Aria Versione Aspirante Montaggio Corpo CappaConnessioni Uscita aria Versione FiltranteConnessione Elettrica Montaggio CaminoCamino superiore Camino inferioreQuadro comandi USOTelecomando Opzionale Reset del segnale di allarmeManutenzione Filtri antigrasso metalliciSostituzione Filtro Antiodore AL Carbone Attivo Pannelli AspirantiFiltri antiodore al Carbone attivo Versione Filtrante Attivazione del segnale di allarmeSostituzione Lampade IlluminazioneLampade alogene da 20 W USE InstallationMaintenance Recommendations and SuggestionsDimensions Components CharacteristicsWall drilling and bracket fixing InstallationConnections Mounting the hood bodyDucted Version AIR Exhaust System Electrical Connection Flue assemblyUpper exhaust flue Lower exhaust flueControl board USECleaning the filters MaintenanceRemote Control Optional Alarm resetCharcoal filter recycling version Comfort panelsReplacing the Charcoal Filter Lighting Light ReplacementHalogen light Utilisation Conseils ET SuggestionsEntretien Encombrement Composants CaracteristiquesPerçage Paroi et Fixation Brides Sortie AIR Version Aspirante Montage Corps HotteBranchements Visser la vis de sécuritéBranchement Electrique Montage CheminéeCheminée supérieure Cheminée inférieureUtilisation Tableau des commandesFiltres à graisse métalliques Telecommande Fournie SUR DemandeRétablissement du signal d’alarme EntretienChangement des Filtres Déclenchement du signal d’alarmePanneaux Aspirants Filtre anti-odeur au charbon actif version filtranteEclairage Remplacement LampesLampe halogène de 20 W Wartung Empfehlungen UND HinweiseMontage BedienungPlatzbedarf Komponenten CharakteristikenMontage Anschlüsse Montage des HaubenkörpersAnschluss in Abluftversion Elektroanschluss KaminmontageOberer Kaminteil Unterer KaminteilBedienblende BedienungFernbedienung Option Reset des AlarmsignalsWartung MetallfettfilterAuswechseln DES AKTIVKOHLE-GERUCHSFILTERS Aktivierung des AlarmsignalsFilterpaneele Aktivkohle-Geruchsfilter FilterversionAuswechseln DER Lampen BeleuchtungHalogenlampe 20 W Montaj Tavsiyeler VE ÖnerilerBoyutlar Komponentler ÖzelliklerDuvarın delinmesi ve kancaların vidalanması MontajAspİratörlü Model Hava Çikişi Davlumbaz gövdesinin montajıBağlantılar Filtreli versiyon hava çıkı şıElektrİk Bağlantisi Baca MontajıÜst baca Alt bacaKumanda Tablosu KullanimTelekumanda Opsİyonel Alarm sinyalinin sıfırlanmasıBakim Madeni yağ filtreleriAKT İF Karbonlu Koku F İltres İN İN DE Ğİşt İR İlmes İ Alarm sinyalinin devreye alınmasıEmme panelleri Aktif karbonlu koku giderici filtreler Filtreli ModelAmpul Değİştİrme AydınlatmaHalojen ampuller 436002965ver1