Franke Consumer Products FQD 907 manual Flue assembly, Upper exhaust flue, Lower exhaust flue

Page 20

Flue assembly

The chimney can only be installed with exhausting hood

Fasten the angle iron 15 to the hood canopy using the screws 12d (2,9 x 9,5) provided.

Upper exhaust flue

Slightly widen the two sides of the upper flue and hook them behind the brackets 7.2.1, making sure that they are well seated.

Secure the sides to the brackets using the 4 screws 12c (2,9 x 6,5) supplied.

Lower exhaust flue

Slightly widen the two sides of the flue and hook them between the upper flue and the wall, making sure that they are well seated.

Fix the lower part laterally to the hood body using the 2 screws 12c (2,9 x 6,5) supplied.

ELECTRICAL CONNECTION

Connect the hood to the mains through a two-pole switch having a contact gap of at least 3 mm.

Remove the grease filters (see paragraph Mainte- nance) being sure that the connector of the feeding cable is correctly inserted in the socket placed on the side of the fan.

2.1

2

2.2

7.2.1

12c

12c

EN

 

2

 

20

Image 20
Contents Istruzioni per l’uso e l’installazione Indice Index Sommaire Inhaltsverzeichnis Içerikler Installazione Consigli E SuggerimentiUSO ManutenzioneCaratteristiche Ingombro ComponentiInstallazione Foratura Parete e Fissaggio StaffeMontaggio Corpo Cappa ConnessioniUscita aria Versione Filtrante Uscita Aria Versione AspiranteMontaggio Camino Camino superioreCamino inferiore Connessione ElettricaUSO Quadro comandiReset del segnale di allarme ManutenzioneFiltri antigrasso metallici Telecomando OpzionalePannelli Aspiranti Filtri antiodore al Carbone attivo Versione FiltranteAttivazione del segnale di allarme Sostituzione Filtro Antiodore AL Carbone AttivoLampade alogene da 20 W IlluminazioneSostituzione Lampade Installation MaintenanceRecommendations and Suggestions USECharacteristics Dimensions ComponentsInstallation Wall drilling and bracket fixingDucted Version AIR Exhaust System Mounting the hood bodyConnections Flue assembly Upper exhaust flueLower exhaust flue Electrical ConnectionUSE Control boardMaintenance Remote Control OptionalAlarm reset Cleaning the filtersReplacing the Charcoal Filter Comfort panelsCharcoal filter recycling version Halogen light Light ReplacementLighting Entretien Conseils ET SuggestionsUtilisation Caracteristiques Encombrement ComposantsPerçage Paroi et Fixation Brides Montage Corps Hotte BranchementsVisser la vis de sécurité Sortie AIR Version AspiranteMontage Cheminée Cheminée supérieureCheminée inférieure Branchement ElectriqueTableau des commandes UtilisationTelecommande Fournie SUR Demande Rétablissement du signal d’alarmeEntretien Filtres à graisse métalliquesDéclenchement du signal d’alarme Panneaux AspirantsFiltre anti-odeur au charbon actif version filtrante Changement des FiltresLampe halogène de 20 W Remplacement LampesEclairage Empfehlungen UND Hinweise MontageBedienung WartungCharakteristiken Platzbedarf KomponentenMontage Anschluss in Abluftversion Montage des HaubenkörpersAnschlüsse Kaminmontage Oberer KaminteilUnterer Kaminteil ElektroanschlussBedienung BedienblendeReset des Alarmsignals WartungMetallfettfilter Fernbedienung OptionAktivierung des Alarmsignals FilterpaneeleAktivkohle-Geruchsfilter Filterversion Auswechseln DES AKTIVKOHLE-GERUCHSFILTERSHalogenlampe 20 W BeleuchtungAuswechseln DER Lampen Tavsiyeler VE Öneriler MontajÖzellikler Boyutlar KomponentlerMontaj Duvarın delinmesi ve kancaların vidalanmasıDavlumbaz gövdesinin montajı BağlantılarFiltreli versiyon hava çıkı şı Aspİratörlü Model Hava ÇikişiBaca Montajı Üst bacaAlt baca Elektrİk BağlantisiKullanim Kumanda TablosuAlarm sinyalinin sıfırlanması BakimMadeni yağ filtreleri Telekumanda OpsİyonelAlarm sinyalinin devreye alınması Emme panelleriAktif karbonlu koku giderici filtreler Filtreli Model AKT İF Karbonlu Koku F İltres İN İN DE Ğİşt İR İlmes İHalojen ampuller AydınlatmaAmpul Değİştİrme 436002965ver1