GSI Outdoors 2TAF, 2TFC installation instructions Actuator Control Box Mounting

Page 13

2000 Autoflow

CONTROL BOX MOUNTING

Actuator Control Box Mounting

1)Mark the third sidewall ring from the ground to indicate the cable path if dump chutes and cable are already installed.

2)Make sure that all dump chutes and chains are EVENLY adjusted so that when one chute is level the others are level as well.

3)Keep in mind that wire will be used to interconnect the Actuator Control Box with the Autoflow Control Box; and, that a 110V power supply will need to run from the entrance panel to the Actuator Control Box to power the 24V DC battery charger.

4)Use the pattern in Figure 3 to drill holes for the Actuator Control Box.

5)If the horizontal seam bolts are within 1” horizontally of the hole pattern shown, existing holes may be used to attach the actuator.

6)Use four 5/16” x 1.1/4” bin bolts and washers with bolt heads to the

Actuator Control Box Mounted to Bin

inside of the bin.

7)Do not attach the dump chute cable to the actuator at this time. The cable should not be installed until after the actuator unit is completely wired and tested.

13

Image 13
Contents Series Autoflow Fan/Heater Control Installation Instructions Autoflow Table of Contents Series 2000 Autoflow Installation & Operating Instructions Roof WARNING, Operation & SafetySafety Alert Symbol Roof Damage Warning and DisclaimerSafety Use Caution Operation of this Equipment Safety PrecautionsSafety SIGN-OFF Sheet Fan and Heater Mounting InstallationTop Dry Bin Eave Height Autoflow Control Box MountingComponent Placement Series 2000 Autoflow Control Box Bolt Pattern Fill System Control Box Mounting Control BOX MountingFill System Control Box Bolt Pattern Actuator Control Box Mounting Bolt pattern to drill holes for the Actuator Control Box Multi-Grain Temperature Sensor Grain Temperature Sensor Mounted to Leveling Band Post Close-Up Detail of Grain Temperture Sensor Wiring Plenum Temperature Sensor Airswitch Installation Wet Supply Rotary Switch Installation Storage Chamber High Limit Rotary Switch Installation Installation Drying Chamber Rotary Switches Mounted in Bin Roof Drying Chamber Low-Level Rotary Switch Installation Installation Drying Chamber High-Level Rotary Switch Installation Installation Drying Chamber Overflow Rotary Switch Installation Installation Liquid Propane LP Natural Gas NG Conduit Runs Control Wires Electrical Power SupplyPower/Motor Wires GroundingTransformer and Wiring Voltage Drop Power SupplyProper Installation of Ground Rod Machine to Earth GroundingTop Dry and ground rod attachment illustration Main Power Schematic POWER/MOTOR WiringElectrical Load Information Voltage Horsepower Wire Size InformationStarter Fill System Control Box Electrical Load InformationElectrical Power Supply Autoflow to Master Fan/Heater Unit Interconnect Autoflow to Actuator Interconnect Autoflow to Wet Supply Rotary Switch Interconnect Autoflow to Storage Chamber Rotary Switch Inerconnect Autoflow to Drying Chamber Rotary Switches Interconnect Electrial Power SupplyElectrial Power Supply Autoflow to Fill System Control Box Interconnect Autoflow to Ground Interconnect Master to Slave Interconnect Slave to Slave Interconnect Battery Hook-Up Dump Chute Cable Installation Electrical Power Supply Warranty Revision #1 February Airstream Grain Conditioning Systems