ELECTRICAL POWER SUPPLY
2000 Autoflow
Autoflow to Master Fan/Heater Unit Interconnect
The Master Fan/Heater Unit is the only fan and heater in a single fan unit. In two fan units it is the fan/heater with the airswitch, plenum temperature sensor, and grain temperature sensor connected to it. DO NOT run the control wires for the Master Fan/Heater in the same conduit as the power wires for the fan motor. To wire the Master Fan/Heater Unit to the Autoflow Control Box do the following.
Important!
NOTE: Do NOT use solid wire for interconnections.
NOTE: A shielded 16 gauge cable is recommended for use on the network connection. The network wires for this configuration are attached to terminals number 4 and 5. Ground each end of the shielded cable to the housing. A shielded 16 gauge 2 wire cable can be purchased from GSI. Part #
1)Run five (5) control wires from the Autoflow Control Box to the Master Fan/Heater Unit.
2)Connect the wires as shown in figure 19.
Figure 19
42