2000 Autoflow
ELECTRICAL POWER SUPPLY
Autoflow to Actuator Interconnect
The Actuator Control Box houses the 24V DC linear actuator, two (2) 12V DC Batteries, and a 24V DC battery charger. The linear actuator raises and lowers the dump chutes to unload grain automatically from the drying chamber to the storage chamber. The two (2) 12V DC batteries act as a backup to prevent wet grain from dumping into the storage chamber during a power outage. The 24V DC battery charger provides a continuous recharge to the batteries.
To wire the Actuator Control Box to the Autoflow Control Box do the following.
1)Run five (5) control wires from the Autoflow Control Box to the Actuator Control Box.
2)Run three (3) power wires from the Entrance Panel to the Actuator Control Box.
3)Connect the wires as shown in figure 20.
Figure 20
43