ELECTRICAL POWER SUPPLY
2000 Autoflow
Battery Hook-Up
Two (2) lawn and garden type 12V DC Batteries are required for proper operation of the Actuator Control Box. The two (2) 12V DC batteries are wired in series to provide the 24V DC linear actuator with the voltage required to operate. The two (2) 12V DC batteries should be mounted on the shelves provided in the Actuator Control Box.
To wire the two (2) 12V DC batteries to the 24V DC battery charger do the following:
1)Mount the two (2) 12V DC batteries in the Actuator Control Box on the proper shelves.
terminal on one battery to the positive terminal on the other battery.
3)Attach the red wire coming from the fuse block and the positive lead on the 24V DC battery charger to the open positive terminal on one battery.
4)Attach the black wire coming from the fuse block; and the negative lead on the 24V DC battery charger to the open negative terminal on the other battery.
5)Use Figure 28 to guide installation.
2) Install a jumper from the negative
Figure 28
52