Lennox International Inc G24-200 G24−200 FIELD WIRING DIAGRAM 120V SINGLE PH 60HZ, box right side

Page 28
G24−200 FIELD WIRING DIAGRAM (120V SINGLE PH 60HZ)

G24−200 FIELD WIRING DIAGRAM (120V SINGLE PH 60HZ)

 

 

 

 

 

 

 

 

 

 

 

 

 

FUSED OR CIRCUIT BREAKER

 

 

 

 

 

 

 

 

 

 

 

 

 

DISCONNECT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(Furnished by

 

 

 

COMBUSTION

PRIMARY

 

 

 

 

COMBUSTION

PRIMARY

PRESSURE

installer)

 

 

 

PRESSURE

 

L1 N

GND

 

 

AIR BLOWER

LIMIT

 

 

AIR BLOWER

LIMIT

SWITCH

 

 

 

SWITCH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GAS

IGNITION

 

 

 

GAS

IGNITION

 

 

 

 

 

CONTROL

 

 

 

CONTROL

 

 

 

 

 

VALVE

 

 

 

VALVE

 

 

 

 

 

 

BOARD

 

 

 

 

BOARD

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FLAME ROLLOUT

 

 

 

(Alternate make-up

 

 

 

 

 

 

 

SWITCH

 

 

 

 

DOOR

 

 

 

 

 

 

DOOR

 

 

 

 

box right side)

 

 

 

 

 

 

 

 

 

 

INTERLOCK

 

 

 

 

 

INTERLOCK

 

BLOWER DECK

 

 

 

 

 

 

 

 

 

 

 

 

 

RED L1

 

 

1

2

3

4 J84

 

 

RED

 

 

 

 

 

 

 

 

 

 

 

 

L1

 

 

 

 

RED L3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RED

 

 

 

PLUG

L3

RED

 

 

 

 

 

 

 

 

 

 

BLUE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MAKE-UP BOX

 

 

 

 

 

 

 

 

MAKE−UP BOX

(Alternate make-up

 

 

 

RED

 

 

 

 

 

 

T13 TRANSFORMER

box left side)

 

 

 

 

 

 

 

 

 

 

 

REMOVE FACTORY-

 

 

 

 

 

 

 

 

 

 

 

See Note 3

 

 

 

T3 TRANSFORMER

 

 

 

 

 

 

 

 

INSTALLED JUMPER IN

 

 

 

 

 

 

 

WHITE

 

 

 

 

 

See Note 3

 

 

 

 

 

RED

 

 

TWO-STAGE MODE

 

 

 

 

 

 

 

 

 

 

 

R3

THERMOSTAT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TERMINAL STRIP

 

BLACK

 

BLACK

 

 

See Note 2

 

 

 

 

 

TB34

RED

WHITE

 

 

 

 

 

C

 

C

 

 

 

See Note 1

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

 

 

 

 

 

 

W1

 

W1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

G

 

 

 

RELAY

 

 

2

 

 

 

 

 

 

 

 

G

 

 

 

 

 

 

 

 

 

 

 

 

 

K109

 

7

2

GROUND

 

 

BLUE

 

W2

 

 

 

 

 

 

LUG

 

 

 

 

W2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BLACK

 

 

 

 

 

 

 

 

 

 

 

 

YELLOW

 

 

 

 

 

 

 

Y1

 

Y1

 

 

 

 

YELLOW

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RELAY

 

 

BLUE

 

WHITE

 

 

L1

L2 L3

Y2

 

Y2

 

 

7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

K105

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BLUE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

R

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

R

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RELAY

 

 

 

 

 

 

 

T1

T2 T3

 

 

 

 

K13

 

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ECONOMIZER

 

 

 

 

K3 CONTACTOR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ECON

 

 

 

 

CONTROL BOX

T1 TRANSFORMER

 

 

 

 

 

TB1 TERMINAL STRIP

 

 

 

24v: blue − yellow

 

 

 

 

 

 

 

 

 

 

 

 

120v: black − white

 

 

 

 

 

 

 

 

 

 

 

 

BLOWER MOTOR

 

 

 

 

 

 

 

 

NOTES :

1 − Relay K109 can be used for an accessory rated at the same voltage as power supply.

 

 

 

 

 

 

 

 

2 − Field installed and supplied resistor (R3), is required in two-stage applications when using electro-mechanical thermo-

 

 

 

stat. (Use a 150 ohm, 10 watt resistor − Lennox part number P−8−6256.)

 

 

 

 

 

3 − The T3 and T13 transformers (54G5201) are marked as follows: 230v between white and black leads and 460v between

 

 

 

white and red leads. However, in this application, each transformer has been used to supply 230v (available between the

 

 

 

white and red leads) to an induce draft blower when 115v is applied between the white and black leads of each transformer.

 

 

 

 

 

 

 

 

 

FIELD-INSTALLED DRIVE KIT COMPONENT

 

 

 

 

 

 

 

 

 

 

FACTORY INSTALLED

 

 

 

 

 

 

 

 

 

 

 

LINE VOLTAGE FIELD INSTALLED

 

 

 

 

 

 

 

 

 

 

24 VOLTS FIELD INSTALLED

 

 

 

FIGURE 15

Page 28

Image 28
Contents INSTALLATION INSTRUCTIONS G24-200 2P0805P504613M WHAT TO DO IF YOU SMELL GASG24−200 Unit Dimensions − inches mm PageG24−200 Filter Box Dimensions − inches mm SIDE VIEWBACK VIEW TOP VIEWG24−200 HEAT SECTION AND CABINET G24−200 Parts ArrangementPage G24−200 BLOWER SECTION G24−200 Parts Arrangement ContinuedPage G24−200 Gas Furnace SafetyShipping and Packing List setting General Combustion, Dilution & Ventilation AirCements and glues EQUIPMENT IN CONFINED SPACE ALL AIR FROM INSIDE Setting Equipment Return Air Plenum / Filter Box InstallationBOTTOM RETURN AIR FILTER BOX INSTALLATION PageBlower Motor / Drive Installation Duct SystemVenting Venting Using a Masonry Chimney Page Page SERVING A SINGLE CATEGORY I APPLIANCE PageSERVING A SINGLE CATEGORY I APPLIANCE PageVENT CONNECTOR CAPACITY SERVING TWO OR MORE CATEGORY I APPLIANCESSERVING TWO OR MORE CATEGORY I APPLIANCES COMMON VENT CAPACITYPage CARBON MONOXIDE POISONING HAZARD VENT TERMINATION CLEARANCES FOR INSTALLATIONS IN THE USA AND CANADAPage Horizontal Venting Gas Piping FIRE OR EXPLOSION HAZARD Electrical G24−200 FIELD WIRING DIAGRAM 120V SINGLE PH 60HZ Alternate make-upbox right side Alternate make-upG24-200FIELD WIRING DIAGRAM G24−200 FIELD WIRING DIAGRAM G UNITS − 460V 3PH 60HZJ UNITS − 575V 3PH 60HZ Alternate make-upFIGURE Page WIRING SCHEMATIC DIAGRAM FOR G24−200 P UNITS − 208/230V 1PH 60 HZY UNITS − 208/230V 3PH 60HZ G UNITS − 460V 3PH 60HZUnit Start−Up Heating Sequence of Operation Other Unit Adjustments and Operation Gas Pressure AdjustmentHigh Altitude Information Temperature Rise Setting blower CFM TABLE DRIVE KIT SPECIFICATIONS TABLE ACCESSORY AIR RESISTANCEPage Repair Parts List G24−200 Start−up and Performance Check ListTroubleshooting NORMAL HEATING MODEABNORMAL HEATING MODE Page3 − OFF NO POWER OR DETECTED FAULT NORMAL HEATING MODEABNORMAL HEATING MODE LED CODESPOWER ON THERMOSTAT CALLS FOR HEAT W1 ENERGIZED IS THE S10 S99 HIGH LIMIT CLOSED? YES COOLING SEQUENCE OF OPERATION FOR TWO CONDENSING UNITSFOR A SINGLE CONDENSING UNIT MANUAL FAN OPERATION