Honeywell Vista-50P/Vista-50PUL manual Partition-Specific Fields, 1st Page Fields

Page 10

Partition-Specific Fields

(Duplicate this page for each partition in the installation.)

To program these fields,

1.Press *91 to select a partition.

2.Enter a partition-specific field number (ex. *09).

3.Make the required entry.

4.Repeat steps 1-3 for each partition in the system.

PARTITION #____ PROGRAM FIELDS

1st Page Fields

*87

ENTRY WARNING

[1]

 

*09 ENTRY DELAY #1

[02]

 

1=continuous; 0=3 beeps

 

00, 02-15 times 15 seconds.

Maximum 03 for UL Listed installations.

*10

EXIT DELAY #1

[03]

 

00, 03-15 times 15 seconds.

 

 

Maximum 04 for UL Listed installations.

 

*11

ENTRY DELAY #2

[06]

 

00, 02-15 times 15 seconds.

 

 

Maximum 03 for UL installations.

 

*88

BURG. ALARM COMM. DELAY

 

[0]

 

1=16 seconds; 0=no delay.

 

 

 

 

 

 

 

 

Must be "0" for UL installations. Must be “1” for SIA

 

installations.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*90

SEC. SUBS. ACCT #

 

 

 

 

 

 

Enter 00-09; B-F (11-15)

[15 15 15 15]

 

 

 

2nd Page Programming Fields (press *94)

*12 EXIT DELAY #2

[08]

00, 03-15 times 15 seconds. Maximum 04 for UL installations.

1*18 AFFECTS LOBBY

[0]

Enter 1 if this partition affects the common lobby; enter 0 if it does not.

*13 ALARM SOUNDER DURATION

[04]

01-15 times 2 minutes.

Must be minimum 16 minutes for UL installations.

1*19 ARMS LOBBY

[0]

Enter 1 if arming this partition attempts to arm lobby; enter 0 if it does not

*16

CONFIRMATION OF ARMING DING

 

1=enable; 0=disable.

 

 

 

Must be "1" for UL installations.

 

 

*22

KEYPAD PANIC ENABLES

[001]

 

 

 

1=enable; 0=disable

995

*23

MULTIPLE ALARMS

 

 

 

1=yes; 0=no.

 

 

 

Must be 1 for UL installations.

 

 

*29

QUICK ARM

 

 

 

1=yes; 0=no

 

 

[0]

 

1*20

EXIT ERROR LOGIC ENABLE

[0]

 

 

 

 

 

0=No; 1=Bypass E/E and Interior zones faulted after exit

 

 

 

 

 

 

 

 

delay.

 

 

 

 

 

1*21

Must be "0" for UL installations.

 

 

 

 

 

EXIT DELAY RESET

[0]

 

 

 

 

 

 

 

 

996

 

999

0=No; 1=Resets Exit Delay to programmed value after zone

 

 

 

 

[1]

 

 

is closed and then faulted prior to end of exit delay.

 

 

 

 

 

 

Must be "0" for UL installations.

 

 

 

 

1*43

 

 

 

 

PERM. KEYPAD BACKLIGHT

[0]

 

 

 

 

[1]

 

 

1=enable; 0=disable. When disabled, display lights when

 

 

 

 

 

 

any key is pressed, and turns off after period of keypad

 

 

 

 

 

 

 

 

inactivity.

 

 

*32

PRIM. SUBS. ACCT #

 

 

 

 

 

 

 

 

 

Enter 00-09; B-F (11-15)

[15 15 15

15]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*38

PREVENT ZONE XX BYPASS

 

[00]

 

 

 

01-86; 000 if all zones (except fire zones)

can be bypassed

*39

ENABLE OPEN/CLOSE REPORT

 

 

 

[0]

 

 

 

 

 

 

 

 

FOR INSTALLER CODE

 

 

 

 

 

 

 

 

 

 

1=enable; 0=disable

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*84

SWINGER SUPPRESSION

 

[01]

 

 

01-15 alarms;

Must be "00" (disabled) for UL installations..

*85 ENABLE DIALER REPORTS FOR PANICS & DURESS

1=enable; [0=disable]

995 996 999 Duress

1*45

EXIT DELAY SOUNDING

[0]

 

 

 

1=enable; 0=disable. Produces quick beeping during exit

 

 

delay if enabled.

 

 

 

 

1*47

CHIME ON EXTERNAL SIREN

[0]

 

 

 

 

 

1=enable; 0=disable

 

 

 

 

1*52

SEND CANCEL IF ALARM + OFF

[1]

 

 

 

 

 

1=no restriction; 0=within Bell Timeout period only

 

 

 

 

 

 

 

 

1*76

ACCESS CONTROL RELAY FOR PART.[00]

 

 

Relay will be pulsed for 2 seconds whenever code + [0] is

 

 

pressed. Enter 00-16; 00=none.

 

 

 

 

 

Must be "00" for UL installations.

 

 

 

 

– 10 –

Image 10
Contents $0&29,67$65,6 9,67$39,67$38 VISTA50P-PRV2 5/04 Rev aTable of Contents Recommended Programming Procedure Field Group Program Field IndexField Group VISTA-50P/VISTA-50PUL Programming Form 59 *62 Alarm Report Codes & ID Digits for Zones Enable OPEN/CLOSE Report forOPEN/CLOSE Report for Keyswitch 64 *67 Alarm Report Codes & ID Digits for ZonesFields 1*28 1*31 are not applicable for UL installations 2nd Page Programming Fields press *943rd Page Programming Fields press *94 Summary of Programming Commands 1st Page Fields Partition-Specific Fields2nd Page Programming Fields press *94 Enable J7 Triggers by Partition Programming With #93 Menu Mode #93 Menu Mode KEY CommandsEnter Zone no Zone ProgrammingSET to CONFIRM? Zone Type PERIMETER03Input S/N AXXX-XXXX Input TypeInput S/N Series Transmitters Loop Designations Xmit to Confirm Press to SkipExpert Mode Zone Programming Program field 200 Number of PartitionsInput S/N XXX-XXXX On this screenFrom Template Entering Wireless KeysPartition Enter Zone no Template Loop Function Wireless Key Default Templates 58045804BD Zone Type Template Loop FunctionZone Descriptors Select Zone Descriptor mode Alpha Descriptors ProgrammingAccept the word Select Default Screen modeSelect Custom Word Mode Select the next wordEnter the custom word number 01-20 you want to create Type the word using one of two methods as followsFollow the same procedure as for custom words Save the word by pressingAlpha Descriptor Vocabulary See the Relay Voice Descriptors section whenRF Expander Device ProgrammingAlpha or Fixed-Word Keypad VIP ModuleRelay Programming AlarmFault TroubleEnter Relay # Relay Devices ProgrammingChoices for Start/Stop Zone Types and System Operations Relay Action No Response Start Event Not UsedRelay Type ECP ECP Address Module RELAY# House Code Start Partn ANY PartitionUnit Code Relay Voice Descriptors Zone List ProgrammingWord Index Custom Word Substitutes for VIP Module Annunciation Custom Word no =QUIT Enter Index #Communication Options by Partition System Layout WorksheetsPartitions System Definitions by Partition enter values or yes/noEvent LOG Types Access Codes & User Definitions for Partitions 1Printer Options Devices keypads, 4204, rf receivers, vip moduleAccess Codes & User Definitions for Partitions 5 Access Codes & User Definitions for Partitions 3Access Codes & User Definitions for Partitions 7 Zone Definition for Zones Zone Definition for Zones Zone Definition for Zones Zone Definition for Zones Input Types Zone Definitions for System Zones 88 89, 90, 91, 97Zone Types ZoneDevice Action Relay Devices WorksheetsApplicable only if relays 4204, or X-10 devices are used EventZT = Zone TYPE/SYSTEM Operation = Partition No -8, 0 = Any#80 & #81 Menu Mode KEY Commands Scheduling Menu PromptsStop Time Scheduling WorksheetsStart Time Time Window NumberSched Num Time Window Days HOLMonth/Day Partition W T F S S HBypass commands Relay commandsArm/Disarm commands Open/Close WindowsArm Window Partition/Windows Disarm WindowHhmm Mon Tue Wed Thu Fri Sat SunPartition/Windows Disarm Window Ademco VISTA-50P/VISTA-50PUL Summary of Connections Eileen Way, Syosset, New York VISTA50P-PRV2 5/04 Rev. a