Honeywell Vista-50P/Vista-50PUL Enable OPEN/CLOSE Report for, OPEN/CLOSE Report for Keyswitch

Page 6

*39

ENABLE OPEN/CLOSE REPORT FOR

[0]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

INSTALLER CODE 1=enable; 0=disable

 

 

 

 

 

*40

OPEN/CLOSE REPORT FOR KEYSWITCH

[0]

 

 

 

 

 

 

 

1=enable; 0=disable

 

 

 

 

 

 

 

 

*41

NORMALLY CLOSED or EOLR (Zones 2-8)

[1]

 

 

 

 

 

 

 

1=N.C.loops; 0=EOLR supervision.

 

 

 

 

 

 

 

 

 

Must be "0" for UL installations.

 

 

 

 

 

 

 

 

*42

DIAL TONE PAUSE

 

 

 

[0]

 

 

 

 

 

 

 

 

 

 

0=5 seconds; 1=11 seconds; 2=30 seconds.

 

 

 

 

 

 

Must be "0" UL Installations.

 

 

 

 

 

 

 

 

*43

DIAL TONE DETECTION

 

 

 

[1]

 

 

 

 

 

 

 

 

 

 

1=wait for true dial tone; 0=pause, then dial

 

 

 

 

 

 

 

 

 

 

 

 

 

*44

RING DETECTION COUNT

[00]

 

 

 

01-14; 15=answering machine; 00=no detection.

 

 

 

 

 

 

Must be "00" for UL Burglary.

 

 

 

 

 

 

 

 

*45

PRIMARY FORMAT

 

 

 

[1]

 

 

 

 

 

 

 

 

 

 

0=Low Speed; 1=Contact ID; 2=ADEMCO High Speed;

 

3= ADEMCO Express

 

 

 

 

 

 

 

 

*46

LOW SPEED FORMAT (Primary)

 

 

 

[0]

 

 

 

 

 

 

 

 

 

 

0= ADEMCO Low Speed; 1=Sescoa/Radionics

 

 

 

 

 

*47

SECONDARY FORMAT

 

 

 

[1]

 

 

 

 

 

 

 

 

 

 

0=Low Speed; 1=Contact ID; 2= ADEMCO High Speed;

 

3= ADEMCO Express

 

 

 

 

 

 

 

 

*48

LOW SPEED FORMAT (Sec.)

 

 

 

[0]

 

 

 

 

 

 

 

 

 

 

0= ADEMCO Low Speed; 1=Sescoa/Radionics

 

 

 

 

 

*49

CHECKSUM VERIFICATION

[0] [0]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1=yes; 0=no

Prim

 

 

 

Sec

*50

SESCOA/RADIONICS SELECT

 

 

 

[0]

 

 

 

 

 

 

 

 

 

*58 SUPERVISORY AND RESTORE CODES FOR ZONES 01-16.Enter 00-09; B-F (11-15). Default = [00 00 00 00 00]

 

 

 

 

Alarm Rst

Trbl

 

Trbl Rst

 

Byp

 

Byp Rst

*59 *62 ALARM REPORT CODES & ID DIGITS FOR ZONES 17-32.

Skip these fields. Use #93 Menu Mode, Zone Programming to program the report codes.

*63 SUPERVISORY AND RESTORE CODES FOR ZONES 17-32.Enter 00-09; B-F (11-15). Default = [00 00 00 00 00]

 

 

 

 

Alarm Rst

Trbl

 

Trbl Rst

 

Byp

 

Byp Rst

*64 *67 ALARM REPORT CODES & ID DIGITS FOR ZONES 33-48.

Skip these fields. Use #93 Menu Mode, Zone Programming to program the report codes.

*68 SUPERVISORY AND RESTORE CODES FOR ZONES 33-48.Enter 00-09; B-F (11-15). Default = [00 00 00 00 00]

 

 

 

 

Alarm Rst

Trbl

 

Trbl Rst

 

Byp

 

Byp Rst

*69 *72 ALARM REPORT CODES & ID DIGITS FOR ZONES 49-64.

Skip these fields. Use #93 Menu Mode, Zone Programming to program the report codes.

*73 SUPERVISORY AND RESTORE CODES FOR ZONES 49-64.Enter 00-09; B-F (11-15). Default = [00 00 00 00 00]

 

 

 

 

Alarm Rst

Trbl

 

Trbl Rst

 

Byp

 

Byp Rst

*74 *77 ALARM REPORT CODES & ID DIGITS FOR ZONES 81-99.

Skip these fields. Use #93 Menu Mode, Zone Programming to program the report codes.

*78 SUPERVISORY AND RESTORE CODES FOR ZONES 81-99.Enter 00-09; B-F (11-15). Default = [00 00 00 00 00]

1=Sescoa; 0=Radionics

 

*51 DUAL REPORTING

[0]

1=yes; 0=no If used with Spilt Reporting "1" option (1*34), alarms and alarm restores go to both primary & secondary numbers, while all other reports go to secondary only. If used with Split Reporting "2" option, alarms and alarm restores go to both, open/close and test messages go to secondary only, while all other reports go to primary.

*52 STANDARD/EXPANDED REPORT FOR PRIMARY

[0 0 0 0 0 0]

Alarm Rstr Byp Trbl O/C LoBat

0=standard; 1=expanded;

Note: Expanded overrides 4+2 format.

*53 STANDARD/EXPANDED REPORT FOR SECONDARY

[0 0 0 0 0 0]

Alarm Rstr Byp Trbl O/C LoBat 0=standard; 1=expanded;

*54 *57 ALARM REPORT CODES & ID DIGITS FOR ZONES 01-16.

Skip these fields. Use #93 Menu Mode, Zone

Programming to program the report codes.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Alarm Rst

Trbl

 

Trbl Rst

ZONE TYPE RESTORE ENABLES

 

 

 

 

*79 FOR ZONE TYPES 1-8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

2

3

4

5

 

 

 

6

 

 

7

8

 

1=enable; [0=disable]

*80 FOR TYPES 9, and 10

1=enable; [0=disable]

 

Byp

 

Byp Rst

9 10

– 6 –

Image 6
Contents $0&29,67$65,6 9,67$39,67$38 VISTA50P-PRV2 5/04 Rev aTable of Contents Recommended Programming Procedure Program Field Index Field GroupField Group VISTA-50P/VISTA-50PUL Programming Form 59 *62 Alarm Report Codes & ID Digits for Zones Enable OPEN/CLOSE Report forOPEN/CLOSE Report for Keyswitch 64 *67 Alarm Report Codes & ID Digits for ZonesFields 1*28 1*31 are not applicable for UL installations 2nd Page Programming Fields press *943rd Page Programming Fields press *94 Summary of Programming Commands Partition-Specific Fields 1st Page Fields2nd Page Programming Fields press *94 Enable J7 Triggers by Partition Programming With #93 Menu Mode #93 Menu Mode KEY CommandsEnter Zone no Zone ProgrammingSET to CONFIRM? Zone Type PERIMETER03Input Type Input S/N AXXX-XXXXInput S/N Series Transmitters Loop Designations Xmit to Confirm Press to SkipExpert Mode Zone Programming Program field 200 Number of PartitionsInput S/N XXX-XXXX On this screenEntering Wireless Keys From TemplatePartition Enter Zone no Template Loop Function Wireless Key Default Templates 58045804BD Zone Type Template Loop FunctionZone Descriptors Select Zone Descriptor mode Alpha Descriptors ProgrammingAccept the word Select Default Screen modeSelect Custom Word Mode Select the next wordEnter the custom word number 01-20 you want to create Type the word using one of two methods as followsFollow the same procedure as for custom words Save the word by pressingAlpha Descriptor Vocabulary See the Relay Voice Descriptors section whenRF Expander Device ProgrammingAlpha or Fixed-Word Keypad VIP ModuleRelay Programming AlarmFault TroubleEnter Relay # Relay Devices ProgrammingChoices for Start/Stop Zone Types and System Operations Relay Action No Response Start Event Not UsedStart Partn ANY Partition Relay Type ECP ECP Address Module RELAY# House CodeUnit Code Relay Voice Descriptors Zone List ProgrammingWord Index Custom Word Substitutes for VIP Module Annunciation Custom Word no =QUIT Enter Index #Communication Options by Partition System Layout WorksheetsPartitions System Definitions by Partition enter values or yes/noEvent LOG Types Access Codes & User Definitions for Partitions 1Printer Options Devices keypads, 4204, rf receivers, vip moduleAccess Codes & User Definitions for Partitions 3 Access Codes & User Definitions for Partitions 5Access Codes & User Definitions for Partitions 7 Zone Definition for Zones Zone Definition for Zones Zone Definition for Zones Zone Definition for Zones Input Types Zone Definitions for System Zones 88 89, 90, 91, 97Zone Types ZoneDevice Action Relay Devices WorksheetsApplicable only if relays 4204, or X-10 devices are used EventZT = Zone TYPE/SYSTEM Operation = Partition No -8, 0 = Any#80 & #81 Menu Mode KEY Commands Scheduling Menu PromptsStop Time Scheduling WorksheetsStart Time Time Window NumberSched Num Time Window Days HOLMonth/Day Partition W T F S S HBypass commands Relay commandsArm/Disarm commands Open/Close WindowsArm Window Partition/Windows Disarm WindowHhmm Mon Tue Wed Thu Fri Sat SunPartition/Windows Disarm Window Ademco VISTA-50P/VISTA-50PUL Summary of Connections Eileen Way, Syosset, New York VISTA50P-PRV2 5/04 Rev. a