VISTA-50P/VISTA-50PUL Programming Form
Some fields are programmed for each partition (shown as shaded fields). If you are programming a
*00 | INSTALLER CODE |
|
| ||||
| Enter 4 digits, |
|
|
|
| ||
*02 |
| *05 RESPONSE TYPES FOR ZONES |
|
|
|
| |
|
|
|
|
| |||
|
| Skip these fields. Use #93 Menu Mode, Zone |
|
| |||
|
| Programming to program the response types. |
|
| |||
|
|
|
|
|
| ||
|
|
|
|
|
| ||
*09 | ENTRY DELAY #1 | [02] |
|
| |||
|
|
|
|
|
|
|
|
| 00, |
|
|
|
| ||
| Maximum "03" for UL. |
|
|
|
| ||
|
|
|
|
|
| ||
*10 | EXIT DELAY #1 | [03] |
|
| |||
|
|
|
|
|
|
|
|
| 00, |
|
|
|
| ||
| Maximum "04" for UL installations. |
|
|
|
| ||
|
|
|
|
|
| ||
*11 | ENTRY DELAY #2 | [06] |
|
| |||
|
|
|
|
|
|
|
|
| 00, | ||||||
| #1). Maximum "03" for UL installations. |
|
|
|
| ||
|
|
|
|
|
| ||
*12 | EXIT DELAY #2 | [08] |
|
| |||
|
|
|
|
|
|
|
|
| 00, | ||||||
| #1). Maximum "04" for UL installations. |
|
|
|
| ||
|
|
|
|
|
| ||
*13 | ALARM SOUNDER DURATION | [04] |
|
| |||
|
|
|
|
|
|
|
|
| |||||||
| installations. |
|
|
|
| ||
*14 | ZONE 9 RESPONSE TIME | [0] |
|
| |||
|
|
*25 | BURG.TRIGGER FOR RESPONSE TYPE 8 | [1] |
|
| ||||||||
| 1=enable; 0=disable |
|
|
|
|
|
|
|
|
|
| |
*26 | INTELLIGENT TEST REPORTING |
| [0] |
|
| |||||||
|
|
| ||||||||||
| 1=yes (no report sent if any other report was recently sent); |
| ||||||||||
| 0=no (send report at programmed interval, field *27) |
|
|
|
| |||||||
| Must be 0 for UL installations. |
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
*27 | TEST REPORT INTERVAL |
| [024] |
|
|
| ||||||
| Enter interval in hours, |
|
|
|
|
| ||||||
| Max. 024 for UL installations. |
|
|
|
|
|
|
|
|
|
| |
*28 | POWER UP IN PREVIOUS STATE |
| [1] |
|
| |||||||
|
|
| ||||||||||
| 1=yes; 0=no; "1" for UL installations. |
|
|
|
|
|
|
|
|
| ||
*29 | QUICK ARM |
|
|
|
|
|
| [1] |
|
| ||
|
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| 1=yes; 0=no |
|
|
|
|
|
|
|
|
|
| |
*30 | TOUCHTONE OR ROTARY DIAL |
| [0] |
|
| |||||||
|
|
| ||||||||||
| 1=TouchTone; 0=rotary |
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
| |
*31 | PABX ACCESS CODE |
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
| |||
*32 | PRIM. SUBS. ACCT # |
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| Enter | 15 | 15] |
|
|
|
|
|
|
| ||
*33 | PRIMARY PHONE NUMBER |
|
|
|
|
|
|
|
|
|
|
Enter 1 for fast response time 10ms Enter 0 for normal response time 350ms. Must be 0 for UL installations.
*15 | KEYSWITCH ASSIGNMENT | [0] |
|
|
| Enter partition in which keyswitch used, |
|
|
|
|
|
|
| |
*16 | CONFIRMATION OF ARMING DING | [0] |
|
|
|
| |||
|
|
|
|
|
| 1=enable; 0=disable. |
|
|
|
| Must be "1" for UL Installations. |
|
|
|
*17 | AC LOSS KEYPAD SOUNDING | [0] |
|
|
|
| |||
| 1=yes; 0=no |
|
|
|
*19 | RANDOMIZE AC LOSS REPORT | [0] |
|
|
|
|
Enter
*34 SECONDARY PHONE NUMBER
Enter
*35 DOWNLOAD PHONE NO.
*20 VIP MODULE PHONE CODE |
| ||
Enter 01 - 09 for the first digit; enter | [00], | [11] | |
11 for “*” or 12 for “#” for the second digit. |
|
|
|
Must be set to "0" for UL installations. |
|
|
|
*21 | PREVENT FIRE TIMEOUT |
|
| [0] |
|
| ||
| 1=No timeout; 0=Timeout. |
|
|
|
|
|
|
|
*22 | KEYPAD PANIC ENABLES | [001] |
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
| 1=enable; 0=disable | 995 | 996 999 |
| ||||
*23 | MULTIPLE ALARMS |
|
| [1] |
|
| ||
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
| 1=yes; 0=no |
|
|
|
|
|
|
|
*24 | IGNORE EXPANSION ZONE TAMPER | [0] |
|
| ||||
|
|
1=Ignore; 0=Enable tamper for RF and RPMs.
Must be "0" for UL installations if using these devices.
Enter
*36 DOWNLOAD ID NO.
|
|
|
|
|
|
|
Enter
*37 DOWNLOAD COMMAND ENABLES
0
Dlr ShtdwnSys ShtdwnNot UsedRmt BypRmt DisarmRmt ArmUpld PgmDwnld Pgm
See field 1*53 for Callback disable option; [1=enable]; 0=disable. For UL installations, all entries must be "0."
|
|
|
|
*38 PREVENT ZONE XX BYPASS | [00] |
| |
|
|
|
|
– 5 –