Honeywell Ademco Vista Series Commercial Burglary Partitioned Security System With Scheduling

Page 5

VISTA-50P/VISTA-50PUL Programming Form

Some fields are programmed for each partition (shown as shaded fields). If you are programming a multiple-partition system, see the Partition-Specific Fields section for programming these fields. Standard default (*97) values are shown in brackets [ ].

*00

INSTALLER CODE

 

 

 

Enter 4 digits, 0-9 [4140]

 

 

 

 

*02

 

*05 RESPONSE TYPES FOR ZONES

 

 

 

 

 

 

 

 

 

 

 

Skip these fields. Use #93 Menu Mode, Zone

 

 

 

 

Programming to program the response types.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*09

ENTRY DELAY #1

[02]

 

 

 

 

 

 

 

 

 

 

 

00, 02-15 times 15 seconds

 

 

 

 

 

Maximum "03" for UL.

 

 

 

 

 

 

 

 

 

 

*10

EXIT DELAY #1

[03]

 

 

 

 

 

 

 

 

 

 

 

00, 03-15 times 15 seconds

 

 

 

 

 

Maximum "04" for UL installations.

 

 

 

 

 

 

 

 

 

 

*11

ENTRY DELAY #2

[06]

 

 

 

 

 

 

 

 

 

 

 

00, 02-15 times 15 seconds (must be longer than Entry Delay

 

#1). Maximum "03" for UL installations.

 

 

 

 

 

 

 

 

 

 

*12

EXIT DELAY #2

[08]

 

 

 

 

 

 

 

 

 

 

 

00, 03-15 times 15 seconds (must be longer than Exit Delay

 

#1). Maximum "04" for UL installations.

 

 

 

 

 

 

 

 

 

 

*13

ALARM SOUNDER DURATION

[04]

 

 

 

 

 

 

 

 

 

 

 

01-15 times 2 minutes. Must be minimum 16 minutes for UL

 

installations.

 

 

 

 

*14

ZONE 9 RESPONSE TIME

[0]

 

 

 

 

*25

BURG.TRIGGER FOR RESPONSE TYPE 8

[1]

 

 

 

1=enable; 0=disable

 

 

 

 

 

 

 

 

 

 

*26

INTELLIGENT TEST REPORTING

 

[0]

 

 

 

 

 

 

1=yes (no report sent if any other report was recently sent);

 

 

0=no (send report at programmed interval, field *27)

 

 

 

 

 

Must be 0 for UL installations.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*27

TEST REPORT INTERVAL

 

[024]

 

 

 

 

Enter interval in hours, 001-999; 0000=no report;

 

 

 

 

 

 

Max. 024 for UL installations.

 

 

 

 

 

 

 

 

 

 

*28

POWER UP IN PREVIOUS STATE

 

[1]

 

 

 

 

 

 

1=yes; 0=no; "1" for UL installations.

 

 

 

 

 

 

 

 

 

*29

QUICK ARM

 

 

 

 

 

 

[1]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1=yes; 0=no

 

 

 

 

 

 

 

 

 

 

*30

TOUCHTONE OR ROTARY DIAL

 

[0]

 

 

 

 

 

 

1=TouchTone; 0=rotary

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*31

PABX ACCESS CODE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

00-09; B-F (11-15)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*32

PRIM. SUBS. ACCT #

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Enter 00-09; B-F (11-15) [15 15

15

15]

 

 

 

 

 

 

 

*33

PRIMARY PHONE NUMBER

 

 

 

 

 

 

 

 

 

 

Enter 1 for fast response time 10ms Enter 0 for normal response time 350ms. Must be 0 for UL installations.

*15

KEYSWITCH ASSIGNMENT

[0]

 

 

 

Enter partition in which keyswitch used,

 

 

 

 

1-8; 0=disable

 

 

 

*16

CONFIRMATION OF ARMING DING

[0]

 

 

 

 

 

 

 

 

 

 

1=enable; 0=disable.

 

 

 

 

Must be "1" for UL Installations.

 

 

 

*17

AC LOSS KEYPAD SOUNDING

[0]

 

 

 

 

 

1=yes; 0=no

 

 

 

*19

RANDOMIZE AC LOSS REPORT

[0]

 

 

 

 

1=10-40 min; 0=normal report (about 2 min. after AC loss).

Enter 0-9 for each digit. Enter #11 for *, #12 for #, #13 for 2 second pause

*34 SECONDARY PHONE NUMBER

Enter 0-9 for each digit. Enter #11 for *, #12 for #, #13 for 2 second pause

*35 DOWNLOAD PHONE NO.

*20 VIP MODULE PHONE CODE

 

Enter 01 - 09 for the first digit; enter

[00],

[11]

11 for “*” or 12 for “#” for the second digit.

 

 

 

Must be set to "0" for UL installations.

 

 

 

*21

PREVENT FIRE TIMEOUT

 

 

[0]

 

 

 

1=No timeout; 0=Timeout.

 

 

 

 

 

 

 

*22

KEYPAD PANIC ENABLES

[001]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1=enable; 0=disable

995

996 999

 

*23

MULTIPLE ALARMS

 

 

[1]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1=yes; 0=no

 

 

 

 

 

 

 

*24

IGNORE EXPANSION ZONE TAMPER

[0]

 

 

 

 

1=Ignore; 0=Enable tamper for RF and RPMs.

Must be "0" for UL installations if using these devices.

Enter 0-9 for each digit. Enter #11 for *, #12 for #, #13 for 2 second pause

*36 DOWNLOAD ID NO.

 

 

 

 

 

 

 

Enter 00-09; A-F (10-15) [15 15 15 15 15 15 15 15]

*37 DOWNLOAD COMMAND ENABLES

0

Dlr ShtdwnSys ShtdwnNot UsedRmt BypRmt DisarmRmt ArmUpld PgmDwnld Pgm

See field 1*53 for Callback disable option; [1=enable]; 0=disable. For UL installations, all entries must be "0."

 

 

 

 

*38 PREVENT ZONE XX BYPASS

[00]

 

 

 

 

 

01-86; 00 if all zones (except fire zones) can be bypassed

– 5 –

Image 5
Contents VISTA50P-PRV2 5/04 Rev a $0&29,67$65,6 9,67$39,67$38Table of Contents Recommended Programming Procedure Field Group Program Field IndexField Group VISTA-50P/VISTA-50PUL Programming Form OPEN/CLOSE Report for Keyswitch Enable OPEN/CLOSE Report for59 *62 Alarm Report Codes & ID Digits for Zones 64 *67 Alarm Report Codes & ID Digits for Zones2nd Page Programming Fields press *94 Fields 1*28 1*31 are not applicable for UL installations3rd Page Programming Fields press *94 Summary of Programming Commands 2nd Page Programming Fields press *94 Partition-Specific Fields1st Page Fields Enable J7 Triggers by Partition #93 Menu Mode KEY Commands Programming With #93 Menu ModeSET to CONFIRM? Zone ProgrammingEnter Zone no Zone Type PERIMETER03Input S/N Input TypeInput S/N AXXX-XXXX Xmit to Confirm Press to Skip Series Transmitters Loop DesignationsProgram field 200 Number of Partitions Expert Mode Zone ProgrammingOn this screen Input S/N XXX-XXXXPartition Enter Zone no Entering Wireless KeysFrom Template 5804BD Wireless Key Default Templates 5804Template Loop Function Zone Type Template Loop FunctionAlpha Descriptors Programming Zone Descriptors Select Zone Descriptor modeSelect Custom Word Mode Select Default Screen modeAccept the word Select the next wordFollow the same procedure as for custom words Type the word using one of two methods as followsEnter the custom word number 01-20 you want to create Save the word by pressingSee the Relay Voice Descriptors section when Alpha Descriptor VocabularyAlpha or Fixed-Word Keypad Device ProgrammingRF Expander VIP ModuleFault AlarmRelay Programming TroubleChoices for Start/Stop Zone Types and System Operations Relay Devices ProgrammingEnter Relay # Relay Action No Response Start Event Not UsedUnit Code Start Partn ANY PartitionRelay Type ECP ECP Address Module RELAY# House Code Zone List Programming Relay Voice DescriptorsWord Index Custom Word no =QUIT Enter Index # Custom Word Substitutes for VIP Module AnnunciationPartitions System Layout WorksheetsCommunication Options by Partition System Definitions by Partition enter values or yes/noPrinter Options Access Codes & User Definitions for Partitions 1Event LOG Types Devices keypads, 4204, rf receivers, vip moduleAccess Codes & User Definitions for Partitions 7 Access Codes & User Definitions for Partitions 3Access Codes & User Definitions for Partitions 5 Zone Definition for Zones Zone Definition for Zones Zone Definition for Zones Zone Definition for Zones Zone Types Zone Definitions for System Zones 88 89, 90, 91, 97Input Types ZoneApplicable only if relays 4204, or X-10 devices are used Relay Devices WorksheetsDevice Action Event= Partition No -8, 0 = Any ZT = Zone TYPE/SYSTEM OperationScheduling Menu Prompts #80 & #81 Menu Mode KEY CommandsStart Time Scheduling WorksheetsStop Time Time Window NumberMonth/Day Partition HOLSched Num Time Window Days W T F S S HArm/Disarm commands Relay commandsBypass commands Open/Close WindowsHhmm Partition/Windows Disarm WindowArm Window Mon Tue Wed Thu Fri Sat SunPartition/Windows Disarm Window Ademco VISTA-50P/VISTA-50PUL Summary of Connections VISTA50P-PRV2 5/04 Rev. a Eileen Way, Syosset, New York