Honeywell Vista-50P/Vista-50PUL manual ZT = Zone TYPE/SYSTEM Operation, = Partition No -8, 0 = Any

Page 40

ZT = ZONE TYPE/SYSTEM OPERATION

Choices for Start/Stop Zone Types and System Operations:

00

= No Response (Not Used)

 

23

= No Alarm Response

 

43

= Communication failure

01

= Entry/Exit #1

31

= End of Exit Time

44

= RF Low Battery

02

= Entry/exit #2

32

= Start of Entry Time

45

= Polling Loop Failure

03

= Perimeter

33

= Any Burglary Alarm

51

= RF Receiver Failure

04

= Interior Follower

 

 

= Code + [#] + 71 Key Entry

 

 

= Kissoff

34

52

05

= Trouble Day/Alarm Night

35

= Code + [#] + 72 Key Entry

54

= Fire Zone Reset

06

= 24-Hr. Silent

 

 

= At Bell Timeout **

 

 

= Disarm + 1 Minute

36

55

07

= 24-Hr. Audible

37

= 2 Times Bell Timeout **

56

= XX Minutes (enter XX in field 1*74) *

08

= 24-Hr. Auxiliary

38

= Chime

57

= YY Seconds (enter YY in field 1*75) *

09

= Fire Alarm or Trouble

39

= Fire Alarm

58

= Duress

10

= Interior W/Delay

40

= Bypassing

60

= Audio Alarm Verification (must be

20

= Arming-STAY***

41

= AC Power Fail

 

 

selected for both START and STOP

21

= Arming-AWAY****

42

= System Battery Low

 

 

operation)

22

= Disarming (Code + Off)

 

 

 

 

 

 

NOTE: Any zone in "ZT" for Start, going into alarm, fault, or trouble will activate the relay.

Any zone in "ZT" for Stop, that restores will stop the relay action.

*Stop condition only

**Or at Disarming, whichever occurs earlier

***The output also activates when the partition is armed in the INSTANT mode

****The output also activates when the partition is armed in the MAXIMUM mode

P = PARTITION No. 1-8, 0 = Any

ZONE LISTS FOR OUTPUT DEVICES – Programmed in the #93 Menu Mode in the Output Programming Section. Fill in the required data on the worksheet below and follow the procedure shown earlier in this Programming Guide as you enter the data during the displays and prompts that appear in sequence. Up to 8 zone lists may be created

Note: Record desired zone numbers below. More or fewer boxes than shown may be needed, as any list may include any or all of system's zone numbers.

Zone List 1: Started or stopped by zone numbers (enter 00 to end entries).

Zone List 2: Started or stopped by zone numbers (enter 000 to end entries).

Zone List 3: Started or stopped by zone numbers (enter 000 to end entries).

Zone List 4: Started or stopped by zone numbers (enter 000 to end entries).

Zone List 5: Started or stopped by zone numbers (enter 00 to end entries).

Zone List 6: Started or stopped by zone numbers (enter 000 to end entries).

— 40 —

Image 40
Contents $0&29,67$65,6 9,67$39,67$38 VISTA50P-PRV2 5/04 Rev aTable of Contents Recommended Programming Procedure Field Group Program Field IndexField Group VISTA-50P/VISTA-50PUL Programming Form Enable OPEN/CLOSE Report for OPEN/CLOSE Report for Keyswitch59 *62 Alarm Report Codes & ID Digits for Zones 64 *67 Alarm Report Codes & ID Digits for ZonesFields 1*28 1*31 are not applicable for UL installations 2nd Page Programming Fields press *943rd Page Programming Fields press *94 Summary of Programming Commands 1st Page Fields Partition-Specific Fields2nd Page Programming Fields press *94 Enable J7 Triggers by Partition Programming With #93 Menu Mode #93 Menu Mode KEY CommandsZone Programming SET to CONFIRM?Enter Zone no Zone Type PERIMETER03Input S/N AXXX-XXXX Input TypeInput S/N Series Transmitters Loop Designations Xmit to Confirm Press to SkipExpert Mode Zone Programming Program field 200 Number of PartitionsInput S/N XXX-XXXX On this screenFrom Template Entering Wireless KeysPartition Enter Zone no Wireless Key Default Templates 5804 5804BDTemplate Loop Function Zone Type Template Loop FunctionZone Descriptors Select Zone Descriptor mode Alpha Descriptors ProgrammingSelect Default Screen mode Select Custom Word ModeAccept the word Select the next wordType the word using one of two methods as follows Follow the same procedure as for custom wordsEnter the custom word number 01-20 you want to create Save the word by pressingAlpha Descriptor Vocabulary See the Relay Voice Descriptors section whenDevice Programming Alpha or Fixed-Word KeypadRF Expander VIP ModuleAlarm FaultRelay Programming TroubleRelay Devices Programming Choices for Start/Stop Zone Types and System OperationsEnter Relay # Relay Action No Response Start Event Not UsedRelay Type ECP ECP Address Module RELAY# House Code Start Partn ANY PartitionUnit Code Relay Voice Descriptors Zone List ProgrammingWord Index Custom Word Substitutes for VIP Module Annunciation Custom Word no =QUIT Enter Index #System Layout Worksheets PartitionsCommunication Options by Partition System Definitions by Partition enter values or yes/noAccess Codes & User Definitions for Partitions 1 Printer OptionsEvent LOG Types Devices keypads, 4204, rf receivers, vip moduleAccess Codes & User Definitions for Partitions 5 Access Codes & User Definitions for Partitions 3Access Codes & User Definitions for Partitions 7 Zone Definition for Zones Zone Definition for Zones Zone Definition for Zones Zone Definition for Zones Zone Definitions for System Zones 88 89, 90, 91, 97 Zone TypesInput Types ZoneRelay Devices Worksheets Applicable only if relays 4204, or X-10 devices are usedDevice Action EventZT = Zone TYPE/SYSTEM Operation = Partition No -8, 0 = Any#80 & #81 Menu Mode KEY Commands Scheduling Menu PromptsScheduling Worksheets Start TimeStop Time Time Window NumberHOL Month/Day PartitionSched Num Time Window Days W T F S S HRelay commands Arm/Disarm commandsBypass commands Open/Close WindowsPartition/Windows Disarm Window HhmmArm Window Mon Tue Wed Thu Fri Sat SunPartition/Windows Disarm Window Ademco VISTA-50P/VISTA-50PUL Summary of Connections Eileen Way, Syosset, New York VISTA50P-PRV2 5/04 Rev. a